1,509 research outputs found

    On the differences between bubble-mediated air-water transfer in freshwater and seawater

    Get PDF
    Bubble populations and gas transfer velocities were measured in cleaned and surfactant-influenced freshwater and seawater. A nonlinear fitting technique was used to partition the total gas transfer velocity for a gas in each water type into a turbulence- and bubble-mediated fraction. This showed that the bubble-mediated transfer fraction was larger in cleaned freshwater than in cleaned seawater and that the difference was a function of diffusivity and solubility. This was explained by the fact that the bubble measurements showed that bubble plumes in cleaned freshwater had a higher concentration of large bubbles and a lower concentration of small bubbles than the plumes in cleaned seawater. The differences between the behavior of the bubble-mediated gas flux in cleaned freshwater and cleaned seawater show that caution should be used when intercomparing laboratory results from measurements made in different media. These differences also will make parameterizations of bubble-mediated gas exchange developed using freshwater laboratory data difficult to apply directly to oceanic conditions. It was found that adding a surfactant to seawater had minimal impact on the concentration of bubbles in the plumes. Because surfactants decrease the gas flux to the individual bubbles, the similarity in bubble population meant that the addition of surfactant to seawater decreased the bubble-mediated gas flux compared to the flux in cleaned seawater. In contrast, the addition of a surfactant to freshwater increased the concentration of bubbles by over an order of magnitude. This increase in bubble population was large enough to offset the decrease in the flux to the individual bubbles so that the net bubble-mediated gas flux in freshwater increased when surfactant was added. This difference in behavior of the bubble population and bubble-mediated transfer velocity between surfactant-influenced and cleaned waters further complicates interrelating laboratory measurements and applying laboratory results to the ocean

    Single-photon emitting diode in silicon carbide

    Full text link
    Electrically driven single-photon emitting devices have immediate applications in quantum cryptography, quantum computation and single-photon metrology. Mature device fabrication protocols and the recent observations of single defect systems with quantum functionalities make silicon carbide (SiC) an ideal material to build such devices. Here, we demonstrate the fabrication of bright single photon emitting diodes. The electrically driven emitters display fully polarized output, superior photon statistics (with a count rate of >>300 kHz), and stability in both continuous and pulsed modes, all at room temperature. The atomic origin of the single photon source is proposed. These results provide a foundation for the large scale integration of single photon sources into a broad range of applications, such as quantum cryptography or linear optics quantum computing.Comment: Main: 10 pages, 6 figures. Supplementary Information: 6 pages, 6 figure

    Histopathological study of prostatic lesions in correlation with serum prostate specific antigen levels in elderly men

    Get PDF
    Background: Prostatic lesions are common among elderly men with urinary complaints. Variety of prostatic lesions range from inflammatory, benign to malignant pathologies. The Prostate specific antigen (PSA) is secreted by glandular epithelium of prostate shows raised serum levels in these pathologies. Usually significant rise is commonly associated with Prostatic adenocarcinomas (PCa) with exceptions.Methods: In this retrospective study, total 63 diagnosed cases of prostatic lesions over a one-year period for which serum PSA levels were available, were selected. Cases without serum PSA levels & inadequate biopsies were excluded. Histological diagnosis of prostatic lesions reconfirmed and its correlation with serum PSA was done.Results: Study included patients with mean age 67.84 years (range: 48-60) at the time of diagnosis. Benign lesions were commonest prostatic lesions accounting for total 54 cases (85.71%) out of which 38 were of Benign prostatic hyperplasia (BPH), 14 cases of BPH with prostatitis while single case each for BPH with granulomatous prostatitis and basal cell hyperplasia. Mean PSA value for benign lesions was 6.57 ng/ml. Total 8 were malignant which included 7 (11.11%) PCa while single (1.59%) case of metastatic transitional cell carcinoma. Mean PSA for PCa were 35.05 ng/ml. Single case (1.59%) of high grade prostatic intraepithelial neoplasia also detected.Conclusion: Common age group at the time of presentation of prostatic pathologies is 60-70 years. The most common prostatic lesions are benign predominantly BPH. PCa are commonest malignancies. Elevated PSA levels >20 ng/ml are commonly observed in PCa. However lower or normal values don’t rule out PCa

    Effect of pre-treatment with catecholamines on cold preservation and ischemia/reperfusion-injury in rats

    Get PDF
    Treatment of organ donors with catecholamines reduces acute rejection episodes and improves long-term graft survival after renal transplantation. The aim of this study was to investigate the effect of catecholamine pre-treatment on ischemia/reperfusion (I/R)- and cold preservation injury in rat kidneys. I/R-injury was induced by clamping the left kidney vessels for 60 min along with a contralateral nephrectomy. Cold preservation injury was induced by storage of the kidneys for 24 h at +4°C in University of Wisconsin solution, followed by syngeneic transplantation. Rats were pre-treated with either dopamine (DA), dobutamine (DB), or norepinephrine (2, 5, and 10 μg/kg/min, each group) intravenously via an osmotic minipump for 24 h before I/R- and cold preservation injury. Pre-treatment with DA (2 or 5 μg/kg/min) and DB (5 μg/kg/min) improved recovery of renal function after I/R-injury and dose dependently reduced mononuclear and major histocompatibility complex class II-positive cells infiltrating the kidney after I/R-injury. One day after I/R-injury, upregulation of transforming growth factor (TGF)-β 1 and 2 and phosphorylation of p42/p44 mitogen-activated protein kinases was observed in kidneys of animals treated with DA or DB. DA (5 μg/kg/min) and DB (5 μg/kg/min) pre-treatment reduced endothelial cell damage after 24 h of cold preservation. Only DA pre-treatment improved renal function and reduced renal inflammation after 24 h of cold preservation and syngeneic transplantation. Our results demonstrate a protective effect of pre-treatment with catecholamines on renal inflammation and function after I/R- or cold preservation injury. This could help to explain the potent organoprotective effects of catecholamine pre-treatment observed in human kidney transplantation

    Optical Properties of Deep Ice at the South Pole - Absorption

    Get PDF
    We discuss recent measurements of the wavelength-dependent absorption coefficients in deep South Pole ice. The method uses transit time distributions of pulses from a variable-frequency laser sent between emitters and receivers embedded in the ice. At depths of 800 to 1000 m scattering is dominated by residual air bubbles, whereas absorption occurs both in ice itself and in insoluble impurities. The absorption coefficient increases approximately exponentially with wavelength in the measured interval 410 to 610 nm. At the shortest wavelength our value is about a factor 20 below previous values obtained for laboratory ice and lake ice; with increasing wavelength the discrepancy with previous measurements decreases. At around 415 to 500 nm the experimental uncertainties are small enough for us to resolve an extrinsic contribution to absorption in ice: submicron dust particles contribute by an amount that increases with depth and corresponds well with the expected increase seen near the Last Glacial Maximum in Vostok and Dome C ice cores. The laser pulse method allows remote mapping of gross structure in dust concentration as a function of depth in glacial ice.Comment: 26 pages, LaTex, Accepted for publication in Applied Optics. 9 figures, not included, available on request from [email protected]

    The Highest Energy Neutrinos

    Full text link
    Measurements of the arrival directions of cosmic rays have not revealed their sources. High energy neutrino telescopes attempt to resolve the problem by detecting neutrinos whose directions are not scrambled by magnetic fields. The key issue is whether the neutrino flux produced in cosmic ray accelerators is detectable. It is believed that the answer is affirmative, both for the galactic and extragalactic sources, provided the detector has kilometer-scale dimensions. We revisit the case for kilometer-scale neutrino detectors in a model-independent way by focussing on the energetics of the sources. The real breakthrough though has not been on the theory but on the technology front: the considerable technical hurdles to build such detectors have been overcome. Where extragalactic cosmic rays are concerned an alternative method to probe the accelerators consists in studying the arrival directions of neutrinos produced in interactions with the microwave background near the source, i.e. within a GZK radius. Their flux is calculable within large ambiguities but, in any case, low. It is therefore likely that detectors that are larger yet by several orders of magnitudes are required. These exploit novel techniques, such as detecting the secondary radiation at radio wavelengths emitted by neutrino induced showers.Comment: 16 pages, pdflatex, 7 jpg figures, ICRC style files included. Highlight talk presented at the 30th International Cosmic Ray Conference, Merida, Mexico, 200

    Depletion of nitrogen-vacancy color centers in diamond via hydrogen passivation

    Full text link
    We show a marked reduction in the emission from nitrogen-vacancy (NV) color centers in single crystal diamond due to exposure of the diamond to hydrogen plasmas ranging from 700{\deg}C to 1000{\deg}C. Significant fluorescence reduction was observed beneath the exposed surface to at least 80mm depth after ~10 minutes, and did not recover after post-annealing in vacuum for seven hours at 1100{\deg}C. We attribute the fluorescence reduction to the formation of NVH centers by the plasma induced diffusion of hydrogen. These results have important implications for the formation of nitrogen-vacancy centers for quantum applications, and inform our understanding of the conversion of nitrogen-vacancy to NVH, whilst also providing the first experimental evidence of long range hydrogen diffusion through intrinsic high-purity diamond material.Comment: 6 pages, 3 figure

    Limits on models of the ultrahigh energy cosmic rays based on topological defects

    Get PDF
    An erratum exists for this article. Please see the description link below for details.Using the propagation of ultrahigh energy nucleons, photons, and electrons in the universal radiation backgrounds, we obtain limits on the luminosity of topological defect scenarios for the origin of the highest energy cosmic rays. The limits are set as a function of the mass of the X particles emitted by the cosmic strings or other defects, the cosmological evolution of the topological defects, and the strength of the extragalactic magnetic fields. The existing data on the cosmic ray spectrum and on the isotropic 100 MeV gamma-ray background limit significantly the parameter space in which topological defects can generate the flux of the highest energy cosmic rays, and rule out models with the standard X-particle mass of 10¹⁶GeV and higher.R. J. Protheroe and Todor Stane
    corecore