25 research outputs found

    Using conducting polymers as active agents for marine antifouling paints

    Get PDF
    Antifouling coatings were prepared with paints containing polyaniline (PAni) and derivatives as active pigment, and evaluated by antifouling performance on metallic or polyvinyl chloride substrates. The paints, PAni and its derivatives were characterized by FT-IR spectrophotometry, thermogravimetric analysis, electrical conductivity and scanning electron microscopy. Coatings were also characterized by salt spray, leaching and erosion tests. Antifouling coatings’ performance was evaluated by immersion tests in a marine environment or in fresh water. Paints containing PAni-ES, PAni/DBSA and SPAN, and a co-biocide PyZn, showed antifouling performance similar to a commercial antifouling paint

    Models for random regression for meat quality traits in meat type quails

    Get PDF
    Todos os textos, informa??es e resultados apresentados s?o de inteira responsabilidade dos autores.Objetivou-se com este estudo avaliar modelos para caracter?sticas de qualidade de carne em codornas de corte, alimentadas com diferentes rela??es de treonina:lisina de 1 a 21 dias de idade utilizando regress?o aleat?ria adotando-se homogeneidade e heterogeneidade de vari?ncia residual. Por meio de compara??o dos valores de BIC, o modelo de homogeneidade de vari?ncia foi o que apresentou melhor ajuste para as caracter?sticas estudadas.The objective of this study was to evaluate models for meat quality traits in meat type quails, fed with different relations threonine:lysine from 1 to 21 days of age using random regression analysis, with homogeneity and heterogeneity of residual variance. The model of homogeneity of variance fitter better for the traits studied regarding the comparison of BIC values

    Using Conducting Polymers as Active Agents for Marine Antifouling Paints

    Get PDF
    Antifouling coatings were prepared with paints containing polyaniline (PAni) and derivatives as active pigment, and evaluated by antifouling performance on metallic or polyvinyl chloride substrates. The paints, PAni and its derivatives were characterized by FT-IR spectrophotometry, thermogravimetric analysis, electrical conductivity and scanning electron microscopy. Coatings were also characterized by salt spray, leaching and erosion tests. Antifouling coatings’ performance was evaluated by immersion tests in a marine environment or in fresh water. Paints containing PAni-ES, PAni/DBSA and SPAN, and a co-biocide PyZn, showed antifouling performance similar to a commercial antifouling paint

    O perfil semiológico do paciente portador de hemorragia digestiva alta

    Get PDF
    OBJETIVO: O seguinte estudo objetivou descrever a semiologia do paciente portador de hemorragia digestiva alta, considerando como determinante na avaliação de potencias focos hemorrágicos. METODOLOGIA: Foram realizadas buscas nas plataformas do SciELO, LILACS, PubMed, Scopus e Google Scholar,utilizando os descritores gastrointestinal bleeding, peptic ulcerous disease e varicose hemorrhage, sendo identificados 35 estudos, dos quais foram incluídos 13 artigos completos. Desses estudos, 5 avaliaram as principais etiologias, 2 o surgimento de novos testes diagnósticos, 2 analisaram os aspectos epidemiológicos e 1 a sintomatologia apresentada pelo acometimento da hemorragia digestiva alta. Observou-se inicialmente a abundâncias de informações conceituais sobre o sangramento, como um transtorno clínico comum, acompanhada de inúmeras manifestações, considerando que o foco hemorrágico pode ocorrer em qualquer porção do trato gastrointestinal. Neste estudo, todas as publicações eleitas apresentaram o quadro semiológico composto por algia abdominal, indícios de choque hipovolêmico e taquicardia, alguns exibiram quedas abruptas da pressão arterial, odinofagia, êmese, náuseas e estado ictérico. Os pacientes implicados, cronicamente, já manifestaram ocorrências prévias, devido ao caráter recidivante torna-se essencial investigar a existência de varizes, fístula aorto-entérica, angiodisplasia e doença ulcerosa. CONCLUSÃO: Elucida-se que a hemorragia digestiva alta representa a principal causa de sangramento do trato gastrointestinal, majoritamente manifesta-se como hematêmese ou melena e cursam com o quadro sintomatológico que auxilia na avaliação da gravidade deste e o embasamento de potenciais focos de sangramento e que contribuam para disseminação de informações e intervenções futuras

    Mortality from gastrointestinal congenital anomalies at 264 hospitals in 74 low-income, middle-income, and high-income countries: a multicentre, international, prospective cohort study

    Get PDF
    Summary Background Congenital anomalies are the fifth leading cause of mortality in children younger than 5 years globally. Many gastrointestinal congenital anomalies are fatal without timely access to neonatal surgical care, but few studies have been done on these conditions in low-income and middle-income countries (LMICs). We compared outcomes of the seven most common gastrointestinal congenital anomalies in low-income, middle-income, and high-income countries globally, and identified factors associated with mortality. Methods We did a multicentre, international prospective cohort study of patients younger than 16 years, presenting to hospital for the first time with oesophageal atresia, congenital diaphragmatic hernia, intestinal atresia, gastroschisis, exomphalos, anorectal malformation, and Hirschsprung’s disease. Recruitment was of consecutive patients for a minimum of 1 month between October, 2018, and April, 2019. We collected data on patient demographics, clinical status, interventions, and outcomes using the REDCap platform. Patients were followed up for 30 days after primary intervention, or 30 days after admission if they did not receive an intervention. The primary outcome was all-cause, in-hospital mortality for all conditions combined and each condition individually, stratified by country income status. We did a complete case analysis. Findings We included 3849 patients with 3975 study conditions (560 with oesophageal atresia, 448 with congenital diaphragmatic hernia, 681 with intestinal atresia, 453 with gastroschisis, 325 with exomphalos, 991 with anorectal malformation, and 517 with Hirschsprung’s disease) from 264 hospitals (89 in high-income countries, 166 in middleincome countries, and nine in low-income countries) in 74 countries. Of the 3849 patients, 2231 (58·0%) were male. Median gestational age at birth was 38 weeks (IQR 36–39) and median bodyweight at presentation was 2·8 kg (2·3–3·3). Mortality among all patients was 37 (39·8%) of 93 in low-income countries, 583 (20·4%) of 2860 in middle-income countries, and 50 (5·6%) of 896 in high-income countries (p<0·0001 between all country income groups). Gastroschisis had the greatest difference in mortality between country income strata (nine [90·0%] of ten in lowincome countries, 97 [31·9%] of 304 in middle-income countries, and two [1·4%] of 139 in high-income countries; p≤0·0001 between all country income groups). Factors significantly associated with higher mortality for all patients combined included country income status (low-income vs high-income countries, risk ratio 2·78 [95% CI 1·88–4·11], p<0·0001; middle-income vs high-income countries, 2·11 [1·59–2·79], p<0·0001), sepsis at presentation (1·20 [1·04–1·40], p=0·016), higher American Society of Anesthesiologists (ASA) score at primary intervention (ASA 4–5 vs ASA 1–2, 1·82 [1·40–2·35], p<0·0001; ASA 3 vs ASA 1–2, 1·58, [1·30–1·92], p<0·0001]), surgical safety checklist not used (1·39 [1·02–1·90], p=0·035), and ventilation or parenteral nutrition unavailable when needed (ventilation 1·96, [1·41–2·71], p=0·0001; parenteral nutrition 1·35, [1·05–1·74], p=0·018). Administration of parenteral nutrition (0·61, [0·47–0·79], p=0·0002) and use of a peripherally inserted central catheter (0·65 [0·50–0·86], p=0·0024) or percutaneous central line (0·69 [0·48–1·00], p=0·049) were associated with lower mortality. Interpretation Unacceptable differences in mortality exist for gastrointestinal congenital anomalies between lowincome, middle-income, and high-income countries. Improving access to quality neonatal surgical care in LMICs will be vital to achieve Sustainable Development Goal 3.2 of ending preventable deaths in neonates and children younger than 5 years by 2030

    Rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART): Study protocol for a randomized controlled trial

    Get PDF
    Background: Acute respiratory distress syndrome (ARDS) is associated with high in-hospital mortality. Alveolar recruitment followed by ventilation at optimal titrated PEEP may reduce ventilator-induced lung injury and improve oxygenation in patients with ARDS, but the effects on mortality and other clinical outcomes remain unknown. This article reports the rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART). Methods/Design: ART is a pragmatic, multicenter, randomized (concealed), controlled trial, which aims to determine if maximum stepwise alveolar recruitment associated with PEEP titration is able to increase 28-day survival in patients with ARDS compared to conventional treatment (ARDSNet strategy). We will enroll adult patients with ARDS of less than 72 h duration. The intervention group will receive an alveolar recruitment maneuver, with stepwise increases of PEEP achieving 45 cmH(2)O and peak pressure of 60 cmH2O, followed by ventilation with optimal PEEP titrated according to the static compliance of the respiratory system. In the control group, mechanical ventilation will follow a conventional protocol (ARDSNet). In both groups, we will use controlled volume mode with low tidal volumes (4 to 6 mL/kg of predicted body weight) and targeting plateau pressure &lt;= 30 cmH2O. The primary outcome is 28-day survival, and the secondary outcomes are: length of ICU stay; length of hospital stay; pneumothorax requiring chest tube during first 7 days; barotrauma during first 7 days; mechanical ventilation-free days from days 1 to 28; ICU, in-hospital, and 6-month survival. ART is an event-guided trial planned to last until 520 events (deaths within 28 days) are observed. These events allow detection of a hazard ratio of 0.75, with 90% power and two-tailed type I error of 5%. All analysis will follow the intention-to-treat principle. Discussion: If the ART strategy with maximum recruitment and PEEP titration improves 28-day survival, this will represent a notable advance to the care of ARDS patients. Conversely, if the ART strategy is similar or inferior to the current evidence-based strategy (ARDSNet), this should also change current practice as many institutions routinely employ recruitment maneuvers and set PEEP levels according to some titration method.Hospital do Coracao (HCor) as part of the Program 'Hospitais de Excelencia a Servico do SUS (PROADI-SUS)'Brazilian Ministry of Healt

    Degradação de embalagens de polímeros commodities sob efeito de microondas

    Get PDF
    Os fornos de microondas cada vez ganham mais importância no dia-a-dia, devido à economia de tempo no ato de aquecer ou cozinhar os alimentos que este eletrodoméstico propicia. Como conseqüência, ocorreu o desenvolvimento de novos materiais que são utilizados para armazenar alimentos, geralmente embalagens poliméricas que vieram substituir recipientes e cerâmicos em fornos de microondas. Isso se deve as excelentes propriedades de barreira, baixo custo, fácil processamento e leveza, característicos dos materiais poliméricos. Entretanto, ainda há uma grande desconfiança por parte dos consumidores a respeito da interação do polímero com a radiação provinda das microondas. Nesse sentido, o objetivo deste trabalho é verificar a degradação de embalagens de polímeros commodities quando expostas as microondas. Este trabalho foi realizado em duas etapas. Na primeira etapa (A), avaliaram-se os parâmetros da embalagem que podem influenciar no aquecimento do alimento sendo estes: altura (7,5 cm e 15 cm) e a área da base (0,5 L, 2,0 e 5,0 L); o volume de líquido (100 mL e 400 mL de água) e a utilização de tampa em garrafas PET. Após a preparação das amostras das garrafas, estas eram colocadas no forno de microondas por um período de 90 s, aqui determinado como ciclo. Para os quatro parâmetros estudados, foram mensuradas as temperaturas a cada ciclo para acompanhamento da eficiência de aquecimento ao longo das exposições as microondas, sendo no total 50 ciclos realizados. Na segunda etapa (B), coletou-se embalagens de PEAD, PVC, PS e PP para estabelecer o efeito da degradação após 50 ciclos de exposição; para isto foram realizados ensaios físicos (picnometria e aparência ao longo de 1, 5, 20 e 50 ciclos de exposição as microondas), análise térmica (DSC, TGA e OIT), análise química (FTIR) e análise reológica (viscosimetria). Resultados mostraram que embalagens com altura de 15 cm, 100 mL de água, provindas de garrafas com volume de 2L, utilizando tampa apresentaram maior eficiência de aquecimento, porém por ser uma altura pouco comum em recipientes para microondas, selecionou-se o de 7,5 cm. Entre os polímeros avaliados determinou-se que o PP, PEAD e PET tiveram maior resistência ao tratamento térmico propiciado pelas microondas ao longo de 50 ciclos de exposição

    Degradação de embalagens de polímeros commodities sob efeito de microondas

    Get PDF
    Os fornos de microondas cada vez ganham mais importância no dia-a-dia, devido à economia de tempo no ato de aquecer ou cozinhar os alimentos que este eletrodoméstico propicia. Como conseqüência, ocorreu o desenvolvimento de novos materiais que são utilizados para armazenar alimentos, geralmente embalagens poliméricas que vieram substituir recipientes e cerâmicos em fornos de microondas. Isso se deve as excelentes propriedades de barreira, baixo custo, fácil processamento e leveza, característicos dos materiais poliméricos. Entretanto, ainda há uma grande desconfiança por parte dos consumidores a respeito da interação do polímero com a radiação provinda das microondas. Nesse sentido, o objetivo deste trabalho é verificar a degradação de embalagens de polímeros commodities quando expostas as microondas. Este trabalho foi realizado em duas etapas. Na primeira etapa (A), avaliaram-se os parâmetros da embalagem que podem influenciar no aquecimento do alimento sendo estes: altura (7,5 cm e 15 cm) e a área da base (0,5 L, 2,0 e 5,0 L); o volume de líquido (100 mL e 400 mL de água) e a utilização de tampa em garrafas PET. Após a preparação das amostras das garrafas, estas eram colocadas no forno de microondas por um período de 90 s, aqui determinado como ciclo. Para os quatro parâmetros estudados, foram mensuradas as temperaturas a cada ciclo para acompanhamento da eficiência de aquecimento ao longo das exposições as microondas, sendo no total 50 ciclos realizados. Na segunda etapa (B), coletou-se embalagens de PEAD, PVC, PS e PP para estabelecer o efeito da degradação após 50 ciclos de exposição; para isto foram realizados ensaios físicos (picnometria e aparência ao longo de 1, 5, 20 e 50 ciclos de exposição as microondas), análise térmica (DSC, TGA e OIT), análise química (FTIR) e análise reológica (viscosimetria). Resultados mostraram que embalagens com altura de 15 cm, 100 mL de água, provindas de garrafas com volume de 2L, utilizando tampa apresentaram maior eficiência de aquecimento, porém por ser uma altura pouco comum em recipientes para microondas, selecionou-se o de 7,5 cm. Entre os polímeros avaliados determinou-se que o PP, PEAD e PET tiveram maior resistência ao tratamento térmico propiciado pelas microondas ao longo de 50 ciclos de exposição

    Characterization of pet filaments, derived from mooring rope, submerged in the brazilian coast

    No full text
    Com o advento de plataformas flutuantes dispostas em laminas d’água, cada vez mais profundas, o desenvolvimento de linhas de ancoragem mais leves, resistentes e economicamente viáveis, foram e estão sendo desenvolvidas, sendo os materiais poliméricos os mais promissores. O poliéster, pela excelente combinação de propriedades (densidade, resistência química, durabilidade, resistência mecânica, custo, etc.) tem-se mostrado como a melhor opção para profundidades de até 2.000 metros. Entretanto, a utilização de cabos poliméricos é uma tecnologia relativamente nova, pois as primeiras instalações realizadas pela Petrobras iniciaram a partir de 1997. Desde lá, muitos testes e simulações foram realizados para avaliar e confirmar o comportamento, durabilidade e segurança destes cabos. Porém, poucas informações estão disponíveis na literatura, a respeito do real comportamento de cabos que estiveram ancorados no ambiente marinho, por diferentes períodos de tempo. Dessa forma, esta dissertação tem como objetivo fornecer mais dados, a respeito da variação das propriedades de fibras constituintes de cabos de ancoragem de poliéster. Para tal, foram caracterizadas fibras virgens, fibras ensaiadas mecanicamente para controle de qualidade e fibras de cabos submersos por 3,5 e 7,0 anos. Os ensaios e as análises apresentados foram realizados para avaliar propriedades óticas (cor, brilho e opacidade), físicas (densidade linear e morfologia), térmicas (grau de cristalinidade, estabilidade térmica, etc.), químicas (composição), mecânicas (alongamento, tenacidade, módulo inicial e força de ruptura) e reológicas (viscosidade e massa molar) dos filamentos. Baseado nos resultados obtidos, pode se verificar alteração na cor (amarelamento) e aumento do brilho, opacidade, estabilidade térmica, grau de cristalinidade, viscosidade e da massa molar dos filamentos ancorados por longos períodos de tempo. Entretanto, embora haja vestígios de degradação nestas fibras, não se observou variação significativa na força necessária para rompê-las. Contudo, estas apresentaram um menor módulo inicial, alongamento e tenacidade de ruptura.With the advent of floating platforms arranged on water in deeper depths, the development of lighter, durable and economically viable mooring lines, were and have been developed, being the polymeric materials the most promising. The polyester, due to an excellent combination of properties (density, chemical resistance, durability, strength, cost, etc.), has been considered as the best option for depths up to 2,000 meters. However, the use of polymeric cables is a relatively new technology, since the first installations performed by Petrobras took place in 1997. Since then, many simulations and tests were performed to evaluate and confirm the performance, durability and safety of such cables. Nevertheless, few information are available in the literature regarding the actual behavior of cables, that were anchored in the marine environment, for different periods of time. Thus, this dissertation aims to provide more data about the variation of the properties of fibers, which are the constituent of polyester anchoring cables. In order to achieve the goal of this dissertation, virgin fibers, mechanically tested for quality control and fiber cables submerged by 3.5 and 7.0 years were characterized. Tests and analyzes presented were conducted to evaluate optical properties (color, brightness and opacity), physical (linear density and morphology), thermal (degree of crystallinity, thermal stability, etc.), chemical (composition), mechanical (stretching, tenacity, initial modulus and breaking strength) and rheological properties (viscosity and molar mass) of filaments. Based on the obtained results, it was possible observe change in color, brightness, opacity, thermal stability, degree of crystallinity, viscosity and molar mass of filaments. However, although there are traces of degradation in the fibers, no significant variation was observed in the force required to break them. On the other hand, the fibers had a lower initial modulus, breaking elongation and toughness
    corecore