219 research outputs found

    Integrated Nonlinear Optics in Silicon Nitride Waveguides

    Get PDF
    Current nanofabrication techniques allow patterning of optical waveguides with submicron cores. This results in strong confinement of light, which leads to high optical intensities. If the waveguides are fabricated with materials that display a large nonlinear Kerr coefficient, then nonlinear optical phenomena can take place in a very efficient manner. Silicon nitride is a very well-studied material in the electronics industry. The material has a large transparency window, from the ultraviolet to the short-wave infrared, and its fabrication is completely compatible with standard techniques formerly developed by the semiconductor industry. Silicon nitride strip waveguides can also confine light, and diverse applications based on nonlinear optics have been demonstrated before. However, these applications required core thickness above 300 nm and they are very challenging to fabricate in a reliable manner with standard deposition techniques. In this thesis, we have studied unconventional silicon nitride waveguides that are more robust for fabrication. The first layout corresponds to a thin strip waveguide with low optical confinement and propagation losses of only 6 dB/m. This technology was originally developed at the University of California, Santa Barbara. We used the technology to demonstrate wavelength conversion of high-speed data. In this thesis, we developed another silicon nitride technology that allowed for high light confinement. We discovered that by modifying the stoichiometry of the film during the deposition process, one could drastically change the optical and mechanical properties of the material. With this technology we demonstrated octave-spanning supercontinuum generation in collaboration with the Technical University of Denmark and XPM-based all-optical processing in collaboration with McGill University. These results indicate that this platform is very suitable for nonlinear integrated optics. The long-term goal of our research is being able to attain an optical parametric amplifier on chip using a continuous-wave pump laser source. In this thesis we benchmarked the losses of high-confinement waveguides for the realization of 10 dB parametric net-gain on chip and identified silicon nitride as the most plausible technology to achieve this goal in the near future

    Systematic review of communication technologies to promote access and engagement of young people with diabetes into healthcare

    Get PDF
    Background: Research has investigated whether communication technologies (e.g. mobile telephony, forums, email) can be used to transfer digital information between healthcare professionals and young people who live with diabetes. The systematic review evaluates the effectiveness and impact of these technologies on communication. Methods: Nine electronic databases were searched. Technologies were described and a narrative synthesis of all studies was undertaken. Results: Of 20,925 publications identified, 19 met the inclusion criteria, with 18 technologies assessed. Five categories of communication technologies were identified: video-and tele-conferencing (n = 2); mobile telephony (n = 3); telephone support (n = 3); novel electronic communication devices for transferring clinical information (n = 10); and web-based discussion boards (n = 1). Ten studies showed a positive improvement in HbA1c following the intervention with four studies reporting detrimental increases in HbA1c levels. In fifteen studies communication technologies increased the frequency of contact between patient and healthcare professional. Findings were inconsistent of an association between improvements in HbA1c and increased contact. Limited evidence was available concerning behavioural and care coordination outcomes, although improvement in quality of life, patientcaregiver interaction, self-care and metabolic transmission were reported for some communication technologies. Conclusions: The breadth of study design and types of technologies reported make the magnitude of benefit and their effects on health difficult to determine. While communication technologies may increase the frequency of contact between patient and health care professional, it remains unclear whether this results in improved outcomes and is often the basis of the intervention itself. Further research is needed to explore the effectiveness and cost effectiveness of increasing the use of communication technologies between young people and healthcare professionals

    Migraine and restless legs syndrome: is there an association?

    Get PDF
    Occasional clinical reports have suggested a link between migraine and restless legs syndrome. We undertook a systematic review of the evidence, which supports this association, and consider possible shared pathogenic mechanisms and the implications for current clinical practice

    A review of elliptical and disc galaxy structure, and modern scaling laws

    Full text link
    A century ago, in 1911 and 1913, Plummer and then Reynolds introduced their models to describe the radial distribution of stars in `nebulae'. This article reviews the progress since then, providing both an historical perspective and a contemporary review of the stellar structure of bulges, discs and elliptical galaxies. The quantification of galaxy nuclei, such as central mass deficits and excess nuclear light, plus the structure of dark matter halos and cD galaxy envelopes, are discussed. Issues pertaining to spiral galaxies including dust, bulge-to-disc ratios, bulgeless galaxies, bars and the identification of pseudobulges are also reviewed. An array of modern scaling relations involving sizes, luminosities, surface brightnesses and stellar concentrations are presented, many of which are shown to be curved. These 'redshift zero' relations not only quantify the behavior and nature of galaxies in the Universe today, but are the modern benchmark for evolutionary studies of galaxies, whether based on observations, N-body-simulations or semi-analytical modelling. For example, it is shown that some of the recently discovered compact elliptical galaxies at 1.5 < z < 2.5 may be the bulges of modern disc galaxies.Comment: Condensed version (due to Contract) of an invited review article to appear in "Planets, Stars and Stellar Systems"(www.springer.com/astronomy/book/978-90-481-8818-5). 500+ references incl. many somewhat forgotten, pioneer papers. Original submission to Springer: 07-June-201

    Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics

    Get PDF
    A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN

    Challenges in measuring measles case fatality ratios in settings without vital registration

    Get PDF
    Measles, a highly infectious vaccine-preventable viral disease, is potentially fatal. Historically, measles case-fatality ratios (CFRs) have been reported to vary from 0.1% in the developed world to as high as 30% in emergency settings. Estimates of the global burden of mortality from measles, critical to prioritizing measles vaccination among other health interventions, are highly sensitive to the CFR estimates used in modeling; however, due to the lack of reliable, up-to-date data, considerable debate exists as to what CFR estimates are appropriate to use. To determine current measles CFRs in high-burden settings without vital registration we have conducted six retrospective measles mortality studies in such settings. This paper examines the methodological challenges of this work and our solutions to these challenges, including the integration of lessons from retrospective all-cause mortality studies into CFR studies, approaches to laboratory confirmation of outbreaks, and means of obtaining a representative sample of case-patients. Our experiences are relevant to those conducting retrospective CFR studies for measles or other diseases, and to those interested in all-cause mortality studies

    Correlates of protection against symptomatic and asymptomatic SARS-CoV-2 infection

    Get PDF
    The global supply of COVID-19 vaccines remains limited. An understanding of the immune response that is predictive of protection could facilitate rapid licensure of new vaccines. Data from a randomized efficacy trial of the ChAdOx1 nCoV-19 (AZD1222) vaccine in the United Kingdom was analyzed to determine the antibody levels associated with protection against SARS-CoV-2. Binding and neutralizing antibodies at 28 days after the second dose were measured in infected and noninfected vaccine recipients. Higher levels of all immune markers were correlated with a reduced risk of symptomatic infection. A vaccine efficacy of 80% against symptomatic infection with majority Alpha (B.1.1.7) variant of SARS-CoV-2 was achieved with 264 (95% CI: 108, 806) binding antibody units (BAU)/ml: and 506 (95% CI: 135, not computed (beyond data range) (NC)) BAU/ml for anti-spike and anti-RBD antibodies, and 26 (95% CI: NC, NC) international unit (IU)/ml and 247 (95% CI: 101, NC) normalized neutralization titers (NF50) for pseudovirus and live-virus neutralization, respectively. Immune markers were not correlated with asymptomatic infections at the 5% significance level. These data can be used to bridge to new populations using validated assays, and allow extrapolation of efficacy estimates to new COVID-19 vaccines

    Nobody Is Perfect: ERP Effects Prior to Performance Errors in Musicians Indicate Fast Monitoring Processes

    Get PDF
    Background: One central question in the context of motor control and action monitoring is at what point in time errors can be detected. Previous electrophysiological studies investigating this issue focused on brain potentials elicited after erroneous responses, mainly in simple speeded response tasks. In the present study, we investigated brain potentials before the commission of errors in a natural and complex situation. Methodology/Principal Findings: Expert pianists bimanually played scales and patterns while the electroencephalogram (EEG) was recorded. Event-related potentials (ERPs) were computed for correct and incorrect performances. Results revealed differences already 100 ms prior to the onset of a note (i.e., prior to auditory feedback). We further observed that erroneous keystrokes were delayed in time and pressed more slowly. Conclusions: Our data reveal neural mechanisms in musicians that are able to detect errors prior to the execution of erroneous movements. The underlying mechanism probably relies on predictive control processes that compare the predicted outcome of an action with the action goal

    LC-MSsim – a simulation software for liquid chromatography mass spectrometry data

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Mass Spectrometry coupled to Liquid Chromatography (LC-MS) is commonly used to analyze the protein content of biological samples in large scale studies. The data resulting from an LC-MS experiment is huge, highly complex and noisy. Accordingly, it has sparked new developments in Bioinformatics, especially in the fields of algorithm development, statistics and software engineering. In a quantitative label-free mass spectrometry experiment, crucial steps are the detection of peptide features in the mass spectra and the alignment of samples by correcting for shifts in retention time. At the moment, it is difficult to compare the plethora of algorithms for these tasks. So far, curated benchmark data exists only for peptide identification algorithms but no data that represents a ground truth for the evaluation of feature detection, alignment and filtering algorithms.</p> <p>Results</p> <p>We present <it>LC-MSsim</it>, a simulation software for LC-ESI-MS experiments. It simulates ESI spectra on the MS level. It reads a list of proteins from a FASTA file and digests the protein mixture using a user-defined enzyme. The software creates an LC-MS data set using a predictor for the retention time of the peptides and a model for peak shapes and elution profiles of the mass spectral peaks. Our software also offers the possibility to add contaminants, to change the background noise level and includes a model for the detectability of peptides in mass spectra. After the simulation, <it>LC-MSsim </it>writes the simulated data to mzData, a public XML format. The software also stores the positions (monoisotopic m/z and retention time) and ion counts of the simulated ions in separate files.</p> <p>Conclusion</p> <p><it>LC-MSsim </it>generates simulated LC-MS data sets and incorporates models for peak shapes and contaminations. Algorithm developers can match the results of feature detection and alignment algorithms against the simulated ion lists and meaningful error rates can be computed. We anticipate that <it>LC-MSsim </it>will be useful to the wider community to perform benchmark studies and comparisons between computational tools.</p
    corecore