20 research outputs found

    Influence of wear and overwear on surface properties of etafilcon A contact lenses and adhesion of Pseudomonas aeruginosa

    Get PDF
    PURPOSE. To determine changes in physicochemical surface properties of contact tenses (CLs) during daily wear and effects of lens wear on adhesion of a Pseudomonas aeruginosa strain from a patient with CL-related keratitis.METHODS. Ten new CL wearers used ionic, etafilcon A lenses with 58% water on both eyes for approximately 10 hours each day during 10 and 50 days. All lenses were treated daily with an appropriate lens care solution. After the CLs were worn for 10 days (first pair of lenses) and 50 days (second pair, representing overwear), hydrophobicity by water contact angles, surface roughness by atomic force microscope, elemental surface composition by x-ray photoelectron spectroscopy (XPS), and adsorbed proteins by SDS-PAGE were determined on one lens. The lens from the contralateral eye was placed in a parallel plate flow chamber for bacterial adhesion after each time interval.RESULTS. Water contact angles on lenses changed from 45degrees on unused lenses to 61degrees +/- 25degrees after 10 days of wear and changed significantly (P &lt;0.05) to 27degrees +/- 14degrees after 50 days of wear. Surface roughness increased significantly (P &lt;0.05) from 4 +/- 2 nm (unused) to 10 +/- 7 nm after 50 days of wear. These changes were accompanied by adsorption of proteinaceous material, as evidenced by XPS and SDS-PAGE, demonstrating adsorption of lysozyme, tear lipocalin, and a 30-kDa protein. Initial bacterial adhesion to worn CLs was lower than to unworn CLs. Furthermore, detachment of adhering bacteria from worn lenses was easier than from unworn lenses. The changes observed in the physicochemical surface properties of the lenses after the CLs were worn for 50 days were accompanied by reports of discomfort by 6 of the 10 new CL wearers. Multiple regression analysis revealed that the most predictive variables for an effect on initial deposition after 10 days of wear were hydrophobicity, roughness, the presence of nitrogen-rich material, including the presence of a 30-kDa protein, and the presence of oxygen-rich material-that is, the type of oxygen adsorbed (O==C or O-C). After 50 days of wear, roughness and the presence of tear lipocalin were most predictive.CONCLUSIONS. This study demonstrates that the physicochemical surface properties changed after wear and overwear, whereas overwear of the lenses decreased initial adhesion of P. aeruginosa #3 under the present experimental conditions.</p

    Stable X chromosome reactivation in female human induced pluripotent stem cells

    Get PDF
    In placental mammals, balanced expression of X-linked genes is accomplished by X chromosome inactivation (XCI) in female cells. In humans, random XCI is initiated early during embryonic development. To investigate whether reprogramming of female human fibroblasts into induced pluripotent stem cells (iPSCs) leads to reactivation of the inactive X chromosome (Xi), we have generated iPSC lines from fibroblasts heterozygous for large X-chromosomal deletions. These fibroblasts show completely skewed XCI of the mutated X chromosome, enabling monitoring of X chromosome reactivation (XCR) and XCI using allele-specific single-cell expression analysis. This approach revealed that XCR is robust under standard culture conditions, but does not prevent reinitiation of XCI, resulting in a mixed population of cells with either two active X chromosomes (Xas) or one Xa and one Xi. This mixed population of XaXa and XaXi cells is stabilized in naive human stem cell medium, allowing expansion of clones with two Xas

    Heterosexuals at risk for HIV

    No full text

    Influence of wear and overwear on surface properties of etafilcon A contact lenses and adhesion of Pseudomonas aeruginosa

    No full text
    PURPOSE. To determine changes in physicochemical surface properties of contact tenses (CLs) during daily wear and effects of lens wear on adhesion of a Pseudomonas aeruginosa strain from a patient with CL-related keratitis. METHODS. Ten new CL wearers used ionic, etafilcon A lenses with 58% water on both eyes for approximately 10 hours each day during 10 and 50 days. All lenses were treated daily with an appropriate lens care solution. After the CLs were worn for 10 days (first pair of lenses) and 50 days (second pair, representing overwear), hydrophobicity by water contact angles, surface roughness by atomic force microscope, elemental surface composition by x-ray photoelectron spectroscopy (XPS), and adsorbed proteins by SDS-PAGE were determined on one lens. The lens from the contralateral eye was placed in a parallel plate flow chamber for bacterial adhesion after each time interval. RESULTS. Water contact angles on lenses changed from 45degrees on unused lenses to 61degrees +/- 25degrees after 10 days of wear and changed significantly (P <0.05) to 27degrees +/- 14degrees after 50 days of wear. Surface roughness increased significantly (P <0.05) from 4 +/- 2 nm (unused) to 10 +/- 7 nm after 50 days of wear. These changes were accompanied by adsorption of proteinaceous material, as evidenced by XPS and SDS-PAGE, demonstrating adsorption of lysozyme, tear lipocalin, and a 30-kDa protein. Initial bacterial adhesion to worn CLs was lower than to unworn CLs. Furthermore, detachment of adhering bacteria from worn lenses was easier than from unworn lenses. The changes observed in the physicochemical surface properties of the lenses after the CLs were worn for 50 days were accompanied by reports of discomfort by 6 of the 10 new CL wearers. Multiple regression analysis revealed that the most predictive variables for an effect on initial deposition after 10 days of wear were hydrophobicity, roughness, the presence of nitrogen-rich material, including the presence of a 30-kDa protein, and the presence of oxygen-rich material-that is, the type of oxygen adsorbed (O==C or O-C). After 50 days of wear, roughness and the presence of tear lipocalin were most predictive. CONCLUSIONS. This study demonstrates that the physicochemical surface properties changed after wear and overwear, whereas overwear of the lenses decreased initial adhesion of P. aeruginosa #3 under the present experimental conditions

    Influence of wear and overwear on surface properties of Etafilcon A lenses and adhesion of Pseudomonas aeruginosa. Invest Ophthalmol Vis Sci 43

    No full text
    PURPOSE. To determine changes in physicochemical surface properties of contact lenses (CLs) during daily wear and effects of lens wear on adhesion of a Pseudomonas aeruginosa strain from a patient with CL-related keratitis. METHODS. Ten new CL wearers used ionic, etafilcon A lenses with 58% water on both eyes for approximately 10 hours each day during 10 and 50 days. All lenses were treated daily with an appropriate lens care solution. After the CLs were worn for 10 days (first pair of lenses) and 50 days (second pair, representing overwear), hydrophobicity by water contact angles, surface roughness by atomic force microscope, elemental surface composition by x-ray photoelectron spectroscopy (XPS), and adsorbed proteins by SDS-PAGE were determined on one lens. The lens from the contralateral eye was placed in a parallel plate flow chamber for bacterial adhesion after each time interval. RESULTS. Water contact angles on lenses changed from 45°on unused lenses to 61°Ϯ 25°after 10 days of wear and changed significantly (P Ͻ 0.05) to 27°Ϯ 14°after 50 days of wear. Surface roughness increased significantly (P Ͻ 0.05) from 4 Ϯ 2 nm (unused) to 10 Ϯ 7 nm after 50 days of wear. These changes were accompanied by adsorption of proteinaceous material, as evidenced by XPS and SDS-PAGE, demonstrating adsorption of lysozyme, tear lipocalin, and a 30-kDa protein. Initial bacterial adhesion to worn CLs was lower than to unworn CLs. Furthermore, detachment of adhering bacteria from worn lenses was easier than from unworn lenses. The changes observed in the physicochemical surface properties of the lenses after the CLs were worn for 50 days were accompanied by reports of discomfort by 6 of the 10 new CL wearers. Multiple regression analysis revealed that the most predictive variables for an effect on initial deposition after 10 days of wear were hydrophobicity, roughness, the presence of nitrogen-rich material, including the presence of a 30-kDa protein, and the presence of oxygen-rich material-that is, the type of oxygen adsorbed (OAC or OOC). After 50 days of wear, roughness and the presence of tear lipocalin were most predictive. CONCLUSIONS. This study demonstrates that the physicochemical surface properties changed after wear and overwear, whereas overwear of the lenses decreased initial adhesion of P. aeruginosa #3 under the present experimental conditions. (Invest Ophthalmol Vis Sci. 2002;43:3646 -3653

    Influence of day and night wear on surface properties of silicone hydrogel contact lenses and bacterial adhesion

    No full text
    Purpose: The aim of this study was to determine the effect of continuous wear on physicochemical surface properties of silicone hydrogel (S-H) lenses and their susceptibility to bacterial adhesion. Methods: In this study, volunteers wore 2 pairs of either "lotrafilcon A" or "balafilcon A" S-H contact lenses. The first pair was worn continuously for a week and the second pair for 4 weeks. One lens of each pair was used for surface characterization and the other one for bacterial adhesion experiments. Lens surfaces were characterized by examination of their wettability, roughness, elemental composition, and proteins attached to their surfaces. Adhesion of Stapk,lococcus aureus 835 and Pseudomonas aeruginosa #3 to a lens was studied using a parallel plate flow chamber. Results: Before use, the lotrafilcon A lens was rougher than the balafilcon A lens and had a lower water contact angle and a higher affinity for S. aureus 835. After wear, both lens types had similar water contact angles, whereas the differences in elemental surface composition decreased as well. S. aureus 835 adhered in higher numbers to worn balafilcon A lenses, whereas the opposite was seen for P.. aeruginosa #3. The initial deposition rates of both bacterial strains to lotrafilcon A lenses decreased by wearing and were found to correlate significantly (P <0.001) with the surface roughness of worn lenses. Conclusions: In this study, the differences in surface properties between 2 types of S-H lenses were found to change after 1 week of continuous wear. Generally, bacteria adhered in lower numbers and less tenaciously to worn lenses, except S. aureus 835, adhering in higher numbers to worn balafilcon A lenses
    corecore