288 research outputs found

    Exploring individual user differences in the 2D/3D interaction with medical image data

    Get PDF
    User-centered design is often performed without regard to individual user differences. In this paper, we report results of an empirical study aimed to evaluate whether computer experience and demographic user characteristics would have an effect on the way people interact with the visualized medical data in a 3D virtual environment using 2D and 3D input devices. We analyzed the interaction through performance data, questionnaires and observations. The results suggest that differences in gender, age and game experience have an effect on people’s behavior and task performance, as well as on subjective\ud user preferences

    Influence of inspiration level on bronchial lumen measurements with computed tomography

    Get PDF
    SummaryBackgroundBronchial dimensions measured in CT images generally do not take inspiration level into consideration. However, some studies showed that the bronchial membrane is distensible with airway inflation. Therefore, re-examination of the elasticity of bronchi is needed.PurposeTo assess the influence of respiration on bronchial lumen area (defined as distensibility) in different segmental bronchi and to explore the correlations between distensibility and both lung function and emphysema severity.Material and methodsIn 44 subjects with COPD related to alpha-1-antitrypsin deficiency (AATD), bronchial lumen area was measured in CT images, acquired at different inspiration levels. Measurements were done at matched locations in one apical and two basal segmental airways (RB1, RB10 and LB10). Airway distensibility was calculated as lumen area difference divided by lung volume difference.ResultsBronchial lumen area in the lower lobes (RB10 and LB10) correlated positively with FEV1%predicted (p=0.027 for RB10; and p=0.037 for LB10, respectively). Lumen area is influenced by respiration (p=0.006, p=0.045, and, p=0.005 for RB1, RB10 and LB10, respectively). Airway distensibility was different between upper and lower bronchi (p<0.001), but it was not correlated with lung function.ConclusionLumen area of third generation bronchi is dependent on inspiration level and this distensibility is different between bronchi in the upper and lower lobes. Therefore, changes in lumen area over time should be studied whilst accounting for the lung volume changes, in order to estimate the progression of bronchial disease while excluding the effects of hyperinflation

    Normalization of coronary flow reserve by percutaneous transluminal coronary angioplasty

    Get PDF
    Fifteen patients undergoing routine follow-up angiography 5 months after successful percutaneous transluminal coronary angioplasty (PTCA) without angina and with normal exercise thallium scintigraphy were selected for analysis. The coronary flow reserves of these patients were compared with those of 24 patients with angiographically normal coronary arteries to establish whether PTCA can restore to normal the coronary flow reserve of patients with chronic coronary artery disease. The quantitative cineangiographic changes and the concomitant alterations in coronary flow reserve as an immediate result of the PTCA and the subsequent changes 5 months later are described. Coronary flow reserve was measured with digital subtraction cineangiography. PTCA resulted in an increase in minimal obstruction area (mean +/- standard deviation) from 0.8 +/- 0.3 to 3.4 +/- 0.7 mm2 and in coronary flow reserve from 1.0 +/- 0.3 to 2.5 +/- 0.6. Five months later a further substantial and significant (p less than 0.05) late increase in obstruction area (3.8 +/- 0.9 mm2) and flow reserve (3.6 +/- 0.5) had occurred. In 11 of 15 patients coronary flow reserve was restored to normal. Changes in stenosis geometry are likely to be 1 of the major determinants of this late normalization of coronary flow reserve

    Dedicated bifurcation analysis: basic principles

    Get PDF
    Over the last several years significant interest has arisen in bifurcation stenting, in particular stimulated by the European Bifurcation Club. Traditional straight vessel analysis by QCA does not satisfy the requirements for such complex morphologies anymore. To come up with practical solutions, we have developed two models, a Y-shape and a T-shape model, suitable for bifurcation QCA analysis depending on the specific anatomy of the coronary bifurcation. The principles of these models are described in this paper, as well as the results of validation studies carried out on clinical materials. It can be concluded that the accuracy, precision and applicability of these new bifurcation analyses are conform the general guidelines that have been set many years ago for conventional QCA-analyses

    Fusion of 3D QCA and IVUS/OCT

    Get PDF
    The combination/fusion of quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS)/optical coherence tomography (OCT) depends to a great extend on the co-registration of X-ray angiography (XA) and IVUS/OCT. In this work a new and robust three-dimensional (3D) segmentation and registration approach is presented and validated. The approach starts with standard QCA of the vessel of interest in the two angiographic views (either biplane or two monoplane views). Next, the vessel of interest is reconstructed in 3D and registered with the corresponding IVUS/OCT pullback series by a distance mapping algorithm. The accuracy of the registration was retrospectively evaluated on 12 silicone phantoms with coronary stents implanted, and on 24 patients who underwent both coronary angiography and IVUS examinations of the left anterior descending artery. Stent borders or sidebranches were used as markers for the validation. While the most proximal marker was set as the baseline position for the distance mapping algorithm, the subsequent markers were used to evaluate the registration error. The correlation between the registration error and the distance from the evaluated marker to the baseline position was analyzed. The XA-IVUS registration error for the 12 phantoms was 0.03 ± 0.32 mm (P = 0.75). One OCT pullback series was excluded from the phantom study, since it did not cover the distal stent border. The XA-OCT registration error for the remaining 11 phantoms was 0.05 ± 0.25 mm (P = 0.49). For the in vivo validation, two patients were excluded due to insufficient image quality for the analysis. In total 78 sidebranches were identified from the remaining 22 patients and the registration error was evaluated on 56 markers. The registration error was 0.03 ± 0.45 mm (P = 0.67). The error was not correlated to the distance between the evaluated marker and the baseline position (P = 0.73). In conclusion, the new XA-IVUS/OCT co-registration approach is a straightforward and reliable solution to combine X-ray angiography and IVUS/OCT imaging for the assessment of the extent of coronary artery disease. It provides the interventional cardiologist with detailed information about vessel size and plaque size at every position along the vessel of interest, making this a suitable tool during the actual intervention

    New approaches for the assessment of vessel sizes in quantitative (cardio-)vascular X-ray analysis

    Get PDF
    This paper presents new approaches for the assessment of the arterial and reference diameters in (cardio-)vascular X-ray images, designed to overcome the problems experienced in conventional quantitative coronary and vascular angiography approaches. In single or “straight” vessel segments, the arterial and reference diameter directions were made independent of each other in order to be able to measure the minimal lumen diameter (MLD) more accurately, especially in curved vessel segments. For ostial segments, an extension of this approach was used, to allow measurement of ostial lesions in sidebranches more proximal than using conventional methods. Furthermore, two new bifurcation approaches were developed. The validation study shows that the straight segment approach results in significant smaller MLDs (on average 0.032 mm) and the ostial approach achieves on average an increase in %DS of 3.8% and an increase in lesion length of 0.59 mm due to loosening the directional constraint. The validation of our new bifurcation approaches in phantom data as well as clinical data shows only small differences between pre- and post-intervention measurements of the reference diameters outside the bifurcation core (errors smaller than 0.06 mm) and the bifurcation core area (errors smaller than 1.4% for phantom data). In summary, these new approaches have led to further improvements in the quantitative analyses of (cardio-)vascular X-ray angiographies
    corecore