11 research outputs found

    Migration of contaminants from printed masks for children to saliva simulant using liquid chromatography coupled to ion mobility-time of flight-mass spectrometry and gas chromatography-mass spectrometry

    Get PDF
    The COVID-19 pandemic has led to children using polymeric FFP2 and polymeric surgical masks on a daily basis. Children often bite and suck on such masks as they wear them closed to their mouths. In this work, the migration of contaminants from printed and unprinted children`s masks to a saliva simulant has been studied. Liquid chromatography coupled to ion-mobility quadrupole time-of-flight mass spectrometry has been used for the detection and identification of non-volatile migrants. An orthogonal projection to latent structures – discriminant analysis (OPLS-DA) was applied to compare the data from the printed masks against the data from the unprinted ones. Headspace solid phase microextraction coupled to gas chromatography mass spectrometry was used to assess the migration of volatile compounds. Thirteen compounds were found in the masks with concentrations ranging from 5 ng/g to 254 ng/g. Toluene, chlorobenzene, irganox 1076 and 2-(2-butoxyethoxy)ethyl acetate were all found to migrate from the masks studied. Moreover, differences between the migrants from printed and unprinted FFP2 masks were found. Octocrylene, 4-(dimethylamine)benzoate, methyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate and tris(3-methylphenyl)phosphate were found to migrate only from printed masks. Toluene that migrated from all the masks studied and tris(3-methylphenyl)phosphate, that migrated only from printed masks, have been listed as hazardous priority substances

    The migration of NIAS from ethylene-vinyl acetate corks and their identification using gas chromatography mass spectrometry and liquid chromatography ion mobility quadrupole time-of-flight mass spectrometry

    Get PDF
    An exhaustive migration study of eight corks, made of ethylene–vinyl acetate, was carried out to identify any non-volatile and volatile compounds using an untargeted approach. The challenge associated with the structural elucidation of unknowns was undertaken using both ultra-high-performance liquid chromatography coupled to an ion-mobility separation quadrupole-time of flight mass spectrometer and gas chromatography mass spectrometry. A total of fifty compounds were observed to migrate from the corks, and among these additives such as antioxidants (Butyl 4-hydroxybenzoate, Irganox 1010, Irganox 1075, Irgafos 168 and BHT) or lubricants (EBO and octadecanamide, N,N'-1,2-ethanediylbis-) were identified. A high proportion (84%) of the detected compounds was non-intentionally added substances (NIAS), and included several cyclic oligomers with different chain sequences. NIAS, such as 2,6-bis(1,1-dimethylethyl)-4-ethyl and 7,9-ditert-butyl-1-oxaspiro[4.5]deca-6,9-diene-2,8-dione, break-down products, including hexa-, hepta- and nonadecanamide, N,N'-1,2-ethanediylbis-, and oxidation products were also identified. One cork was found to be unsuitable for use as a food contact material

    A collision cross section database for extractables and leachables from food contact materials

    Get PDF
    The chemicals in food contact materials (FCMs) can migrate into food and endanger human health. In this study, we developed a database of traveling wave collision cross section in nitrogen ((CCSN2)-C-TW) values for extractables and leachables from FCMs. The database contains a total of 1038 (CCSN2)-C-TW values from 675 standards including those commonly used additives and nonintentionally added substances in FCMs. The (CCSN2)-C-TW values in the database were compared to previously published values, and 85.7, 87.7, and 64.9% M + H](+), M + Na](+), and M - H](-) adducts showed deviations <2%, with the presence of protomers, post-ion mobility spectrometry dissociation of noncovalent clusters and inconsistent calibration are possible sources of CCS deviations. Our experimental (CCSN2)-C-TW values were also compared to CCS values from three prediction tools. Of the three, CCSondemand gave the most accurate predictions. The (CCSN2)-C-TW database developed will aid the identification and differentiation of chemicals from FCMs in targeted and untargeted analysis

    Prediction of Collision Cross-Section Values for Extractables and Leachables from Plastic Products

    Get PDF
    The use of ion mobility separation (IMS) in conjunction with high-resolution mass spectrometry has proved to be a reliable and useful technique for the characterization of small molecules from plastic products. Collision cross-section (CCS) values derived from IMS can be used as a structural descriptor to aid compound identification. One limitation of the application of IMS to the identification of chemicals from plastics is the lack of published empirical CCS values. As such, machine learning techniques can provide an alternative approach by generating predicted CCS values. Herein, experimental CCS values for over a thousand chemicals associated with plastics were collected from the literature and used to develop an accurate CCS prediction model for extractables and leachables from plastic products. The effect of different molecular descriptors and machine learning algorithms on the model performance were assessed. A support vector machine (SVM) model, based on Chemistry Development Kit (CDK) descriptors, provided the most accurate prediction with 93.3% of CCS values for M + H](+) adducts and 95.0% of CCS values for M + Na](+) adducts in testing sets predicted with <5% error. Median relative errors for the CCS values of the M + H](+) and M + Na](+) adducts were 1.42 and 1.76%, respectively. Subsequently, CCS values for the compounds in the Chemicals associated with Plastic Packaging Database and the Food Contact Chemicals Database were predicted using the SVM model developed herein. These values were integrated in our structural elucidation workflow and applied to the identification of plastic-related chemicals in river water. False positives were reduced, and the identification confidence level was improved by the incorporation of predicted CCS values in the suspect screening workflow

    Ultra-high performance liquid chromatography coupled to ion mobility quadrupole time-of-flight mass spectrometry for the identification of non-volatile compounds migrating from ´natural´ dishes

    Get PDF
    Although most new biomaterials for food industry applications are labelled ‘100% natural fabrication’ and ‘chemical-free’, certain compounds may migrate from those materials to the food, compromis- ing the organoleptic characteristics and safety of the product. In this work, the degree of compound migration from dishes made with four different biomaterials: bamboo, palm leaf, wood and wheat pulp was investigated. Migration tests were carried out using three food simulants, 10% ethanol (sim- ulant A), 3% acetic acid (simulant B), and 95% ethanol (simulant D2). Unequivocal identification of non-intentionally added substances (NIAS) is challenging even when using high-resolution mass spectrometry techniques however, a total of 25 different non-volatile compounds from the migration tests were identified and quantified using Ultra-high performance liquid chromatography coupled to ion mobility quadrupole time-of-flight mass spectrometry (UPLC-IMS-MS). In the bamboo samples three oligomers, cyclic diethylene glycol adipate, 3,6,9,16,19,22-hexaoxabicyclo[22.3.1]-octacosa-1(28),24,26- triene-2,10,15,23-tetrone and 1,4,7,14,17,20-hexaoxacyclohexacosane-8,13,21,26-tetrone exceeded the specified limits of migration

    Improving Target and Suspect Screening High-Resolution Mass Spectrometry Workflows in Environmental Analysis by Ion Mobility Separation

    Get PDF
    Currently, the most powerful approach to monitor organic micropollutants (OMPs) in environmental samples is the combination of target, suspect, and nontarget screening strategies using high-resolution mass spectrometry (HRMS). However, the high complexity of sample matrices and the huge number of OMPs potentially present in samples at low concentrations pose an analytical challenge. Ion mobility separation (IMS) combined with HRMS instruments (IMS−HRMS) introduces an additional analytical dimension, providing extra information, which facilitates the identification of OMPs. The collision cross-section (CCS) value provided by IMS is unaffected by the matrix or chromatographic separation. Consequently, the creation of CCS databases and the inclusion of ion mobility within identification criteria are of high interest for an enhanced and robust screening strategy. In this work, a CCS library for IMS−HRMS, which is online and freely available, was developed for 556 OMPs in both positive and negative ionization modes using electrospray ionization. The inclusion of ion mobility data in widely adopted confidence levels for identification in environmental reporting is discussed. Illustrative examples of OMPs found in environmental samples are presented to highlight the potential of IMS−HRMS and to demonstrate the additional value of CCS data in various screening strategies

    The analysis of the migration of per and poly fluoroalkyl substances (PFAS) from food contact materials using ultrahigh performance liquid chromatography coupled to ion-mobility quadrupole time-of-flight mass spectrometry (UPLC- IMS-QTOF)

    Get PDF
    Per-poly fluoroalkyl substances (PFASs) are a group of synthetic fluorine compounds used in food packaging materials to repel water and fats. This study assessed the chemical migration of PFAS from different food contact materials, including cardboard, recycled cardboard, biopolymer, paper and Teflon trays, from various markets. Migration assays were conducted using Tenax® as a food simulant, which was optimized by subjecting it to three consecutive extractions with 3 mL of ethanol within an hour. The resulting extractions were combined and concentrated to 0.5 mL using a nitrogen stream. The analysis was performed using ultrahigh performance liquid chromatography (UPLC) coupled with ion-mobility (IMS) quadrupole-time-of-flight (QTOF) mass spectrometry, which provided a powerful and novel tool for identifying a library of targets containing collision cross section values (CCS) and increasing confidence in subsequent identifications. Eleven PFAS compounds belonging to the family of perfluorocarboxylic acid, perfluorosulfonic acid and perfluorooctanesulfonamidoacetic acid substances (PFCAs, PFSAs and FOSAAs) were found in packaging samples obtained from China, with migrant concentrations ranging 3.2 and 22.3 μg/kg. In contrast, no detectable levels of PFAS were observed in packaging samples obtained in Spain. All trays tested were deemed to be suitable for use as food contact materials due to the fact that their migrant values were lower than 0.025 mg/kg for PFOA and its salts, and lower than a maximum concentration of 1 mg/kg for PFOA-related compounds

    Exploring soda contamination coming from paper straws through ultra-high-pressure liquid chromatography coupled with an ion mobility-quadrupole time-of-flight analyzer and advanced statistical analysis

    Get PDF
    This study deals with the migration of compounds from printed straws into a carbonated drink (soda), employing an innovative approach that combines Ultra-High-Pressure Liquid Chromatography with Ion Mobility Quadrupole Time of Flight Mass Spectrometry technology. Nineteen compounds were found to migrate to the soda from the nine samples analyzed with concentrations ranging values from 0.015 to 3.6 mg migrant/kg of soda. Variations in the compounds across obtained from three different manufacturers were found. These differences strongly suggest the use of different additives in the production of straws from the different manufacturers. Additionally, discrepancies in the compounds that migrated from the printed straws produced by one manufacturer were identified. Two photoinitiators, 2,2-dimethoxy-2-phenylacetophenone and diphenyl (2,4,6-trimethylbenzoyl)- phosphine oxide and a dye, rhodamine B were found to migrate from the soda to the straws. Particularly interesting was the migration of bis(2-ethylbutyl)phthalate and dioctyl phthalate, both recognized as endocrine disruptors, and 4,4'-methylenedianiline, a primary aromatic amine and suspected carcinogen, which had a migration concentration into the soda surpassing the specific migration limit set by Regulation (EU) No 10/2011. The study underscores that, despite straws not being made of plastic, several concerning compounds that migrated from them were additives commonly found in plastic products. This may suggest that paper straws may not be the safest alternative to plastic straws in terms of food safety

    Application of Ion mobility Spectrometry and the derived collision Cross Section in the Analysis of Environmental Organic Micropollutants

    Get PDF
    Ion mobility spectrometry (IMS) is a rapid gas-phase separation technique, which can distinguish ions on the basis of their size, shape, and charge. The IMS-derived collision cross section (CCS) can serve as additional identification evidence for the screening of environmental organic micropollutants (OMPs). In this work, we summarize the published experimental CCS values of environmental OMPs, introduce the current CCS prediction tools, summarize the use of IMS and CCS in the analysis of environmental OMPs, and finally discussed the benefits of IMS and CCS in environmental analysis. An up-to-date CCS compendium for environmental contaminants was produced by combining CCS databases and data sets of particular types of environmental OMPs, including pesticides, drugs, mycotoxins, steroids, plastic additives, per- and polyfluoroalkyl substances (PFAS), polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and polybrominated diphenyl ethers (PBDEs), as well as their well-known transformation products. A total of 9407 experimental CCS values from 4170 OMPs were retrieved from 23 publications, which contain both drift tube CCS in nitrogen (DTCCSN2) and traveling wave CCS in nitrogen (TWCCSN2). A selection of publicly accessible and in-house CCS prediction tools were also investigated; the chemical space covered by the training set and the quality of CCS measurements seem to be vital factors affecting the CCS prediction accuracy. Then, the applications of IMS and the derived CCS in the screening of various OMPs were summarized, and the benefits of IMS and CCS, including increased peak capacity, the elimination of interfering ions, the separation of isomers, and the reduction of false positives and false negatives, were discussed in detail. With the improvement of the resolving power of IMS and enhancements of experimental CCS databases, the practicability of IMS in the analysis of environmental OMPs will continue to improve
    corecore