6,462 research outputs found
Evaluation of a Tetracycline-Inducible Promoter in Staphylococcus aureus In Vitro and In Vivo and Its Application in Demonstrating the Role of sigB in Microcolony Formation
An inducible promoter system provides a powerful tool for studying the genetic basis for virulence. A variety of inducible systems have been used in other organisms, including pXyl-xylR-inducible promoter, the pSpac-lacI system, and the arabinose-inducible PBAD promoter, but each of these systems has limitations in its application to Staphylococcus aureus. In this study, we demonstrated the efficacy of a tetracycline-inducible promoter system in inducing gene expression in S. aureus in vitro and inside epithelial cells as well as in an animal model of infection. Using the xyl/tetO promoter::gfpuvr fusion carried on a shuttle plasmid, we demonstrated that dose-dependant tetracycline induction, as measured by bacterial fluorescence, occurred in each of the above environments while basal activation under noninduced conditions remained low. To ascertain how the system can be used to elucidate the genetic basis of a pathogenic phenotype, we cloned the sigB gene downstream of the inducible promoter. Induction of SigB expression led to dose-dependent attachment of the tested strain to polystyrene microtiter wells. Additionally, bacterial microcolony formation, an event preceding mature biofilm formation, also increased with tetracycline induction of SigB
Spin dependence of the masses of heavy baryons
It is argued from the systematics of spin-depen\-dent forces between quarks
that two proposed baryon states, named and ,
do not exist.Comment: 6 pages, plainte
Fast Monte Carlo Simulation for Patient-specific CT/CBCT Imaging Dose Calculation
Recently, X-ray imaging dose from computed tomography (CT) or cone beam CT
(CBCT) scans has become a serious concern. Patient-specific imaging dose
calculation has been proposed for the purpose of dose management. While Monte
Carlo (MC) dose calculation can be quite accurate for this purpose, it suffers
from low computational efficiency. In response to this problem, we have
successfully developed a MC dose calculation package, gCTD, on GPU architecture
under the NVIDIA CUDA platform for fast and accurate estimation of the x-ray
imaging dose received by a patient during a CT or CBCT scan. Techniques have
been developed particularly for the GPU architecture to achieve high
computational efficiency. Dose calculations using CBCT scanning geometry in a
homogeneous water phantom and a heterogeneous Zubal head phantom have shown
good agreement between gCTD and EGSnrc, indicating the accuracy of our code. In
terms of improved efficiency, it is found that gCTD attains a speed-up of ~400
times in the homogeneous water phantom and ~76.6 times in the Zubal phantom
compared to EGSnrc. As for absolute computation time, imaging dose calculation
for the Zubal phantom can be accomplished in ~17 sec with the average relative
standard deviation of 0.4%. Though our gCTD code has been developed and tested
in the context of CBCT scans, with simple modification of geometry it can be
used for assessing imaging dose in CT scans as well.Comment: 18 pages, 7 figures, and 1 tabl
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPEnsuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered
Mass sum rules for singly and doubly heavy-flavored hadrons
Regularities in the hadron interaction energies are used to obtain formulas
relating the masses of ground-state hadrons, most of which contain heavy
quarks. Inputs are the constituent quark model, the Feynman-Hellmann theorem,
and the structure of the colormagnetic interaction of QCD. Some of the formulas
can also be obtained from heavy quark effective theory or from
diquark-antiquark supersymmetry. It is argued that the sum rules are more
general than the model from which they are obtained. Where data exist, the
formulas agree quite well with experiment, but most of the sum rules proposed
provide predictions of heavy baryon masses that will be useful for future
measurements.Comment: 13 pages, Plain TeX, no figure
Determination of the b quark mass at the M_Z scale with the DELPHI detector at LEP
An experimental study of the normalized three-jet rate of b quark events with
respect to light quarks events (light= \ell \equiv u,d,s) has been performed
using the CAMBRIDGE and DURHAM jet algorithms. The data used were collected by
the DELPHI experiment at LEP on the Z peak from 1994 to 2000. The results are
found to agree with theoretical predictions treating mass corrections at
next-to-leading order. Measurements of the b quark mass have also been
performed for both the b pole mass: M_b and the b running mass: m_b(M_Z). Data
are found to be better described when using the running mass. The measurement
yields: m_b(M_Z) = 2.85 +/- 0.18 (stat) +/- 0.13 (exp) +/- 0.19 (had) +/- 0.12
(theo) GeV/c^2 for the CAMBRIDGE algorithm. This result is the most precise
measurement of the b mass derived from a high energy process. When compared to
other b mass determinations by experiments at lower energy scales, this value
agrees with the prediction of Quantum Chromodynamics for the energy evolution
of the running mass. The mass measurement is equivalent to a test of the
flavour independence of the strong coupling constant with an accuracy of 7
permil.Comment: 24 pages, 10 figures, Accepted by Eur. Phys. J.
A Determination of the Centre-of-Mass Energy at LEP2 using Radiative 2-fermion Events
Using e+e- -> mu+mu-(gamma) and e+e- -> qqbar(gamma) events radiative to the
Z pole, DELPHI has determined the centre-of-mass energy, sqrt{s}, using energy
and momentum constraint methods. The results are expressed as deviations from
the nominal LEP centre-of-mass energy, measured using other techniques. The
results are found to be compatible with the LEP Energy Working Group estimates
for a combination of the 1997 to 2000 data sets.Comment: 20 pages, 6 figures, Accepted by Eur. Phys. J.
Study of Inclusive J/psi Production in Two-Photon Collisions at LEP II with the DELPHI Detector
Inclusive J/psi production in photon-photon collisions has been observed at
LEP II beam energies. A clear signal from the reaction gamma gamma -> J/psi+X
is seen. The number of observed N(J/psi -> mu+mu-) events is 36 +/- 7 for an
integrated luminosity of 617 pb^{-1}, yielding a cross-section of
sigma(J/psi+X) = 45 +/- 9 (stat) +/- 17 (syst) pb. Based on a study of the
event shapes of different types of gamma gamma processes in the PYTHIA program,
we conclude that (74 +/- 22)% of the observed J/psi events are due to
`resolved' photons, the dominant contribution of which is most probably due to
the gluon content of the photon.Comment: 13 pages, 8 figures, Accepted by Phys. Lett.
The H5 guide system - the latest innovative guide system at the ILL
The H5 program with the complete rebuild of the guide system and the upgrade or renovation of all instruments leads to a tremendous increase of the instrument performances. The improvement was obtained both in terms of more useful flux and upgrade of the different instruments (e.g. higher field density for IN15). In addition, the industrial application instrument D50 offers an addition to the ILL instrument suite (see p. 27 in this issue). With the commissioning of the new spin echo spectrometer WASP in 2016, the H5 program will be completed and a considerable improvement for the ILL instrument park will be finalized
- …