11 research outputs found

    Four-strand hamstring graft is stiffer than a tripled semitendinosus graft in anterior cruciate ligament reconstruction: a cadaveric study

    Get PDF
    Purpose: The aim of this study was to compare the biomechanics of a four-strand hamstring graft with a tripled semitendinosus graft, with and without adjustable extra-cortical button fixation, in a cadaveric model. Methods: Four groups of 10 cadaveric hamstrings were tested: In group A, a tripled semitendinosus graft fixated with two adjustable extra-cortical buttons; in Group B, a four-strand semitendinosus and gracilis graft fixated with an adjustable extra-cortical button and a clamp; in group C, a tripled semitendinosus graft fixated to a steel hook and a clamp; in group D, a four-strand semitendinosus and gracilis graft fixated to a steel hook and a cla

    Anterolateral Ligament Expert Group consensus paper on the management of internal rotation and instability of the anterior cruciate ligament - deficient knee

    Get PDF
    Purpose of this paper is to provide an overview of the latest research on the anterolateral ligament (ALL) and present the consensus of the ALL Expert Group on the anatomy, radiographic landmarks, biomechanics, clinical and radiographic diagnosis, lesion classification, surgical technique and clinical outcomes. A consensus on controversial subjects surrounding the ALL and anterolateral knee instability has been established based on the opinion of experts, the latest publications on the subject and an exchange of experiences during the ALL Experts Meeting (November 2015, Lyon, France). The ALL is found deep to the iliotibial band. The femoral origin is just posterior and proximal to the lateral epicondyle; the tibial attachment is 21.6 mm posterior to Gerdy's tubercle and 4-10 mm below the tibial joint line. On a lateral radiographic view the femoral origin is located in the postero-inferior quadrant and the tibial attachment is close to the centre of the proximal tibial plateau. Favourable isometry of an ALL reconstruction is seen when the femoral position is proximal and posterior to the lateral epicondyle, with the ALL being tight upon extension and lax upon flexion. The ALL can be visualised on ultrasound, or on T2-weighted coronal MRI scans with proton density fat-suppressed evaluation. The ALL injury is associated with a Segond fracture, and often occurs in conjunction with acute anterior cruciate ligament (ACL) injury. Recognition and repair of the ALL lesions should be considered to improve the control of rotational stability provided by ACL reconstruction. For high-risk patients, a combined ACL and ALL reconstruction improves rotational control and reduces the rate of re-rupture, without increased postoperative complication rates compared to ACL-only reconstruction. In conclusion this paper provides a contemporary consensus on all studied features of the ALL. The findings warrant future research in order to further test these early observations, with the ultimate goal of improving the long-term outcomes of ACL-injured patients. Level of evidence Level V-Expert opinion

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Rater agreement reliability of the dial test in the ACL-deficient knee

    No full text
    Abstract Background Posterolateral rotatory instability (PLRI) of the knee can easily be missed, because attention is paid to injury of the cruciate ligaments. If left untreated this clinical instability may persist after reconstruction of the cruciate ligaments and may put the graft at risk of failure. Even though the dial test is widely used to diagnose PLRI, no validity and reliability studies of the manual dial test are yet performed in patients. This study focuses on the reliability of the manual dial test by determining the rater agreement. Methods Two independent examiners performed the dial test in knees of 52 patients after knee distorsion with a suspicion on ACL rupture. The dial test was performed in prone position in 30°, 60° and 90° of flexion of the knees. ≥10° side-to-side difference was considered a positive dial test. For quantification of the amount of rotation in degrees, a measuring device was used with a standardized 6 Nm force, using a digital torque adapter on a booth. The intra-rater, inter-rater and rater-device agreement were determined by calculating kappa (κ) for the dial test. Results A positive dial test was found in 21.2% and 18.0% of the patients as assessed by a blinded examiner and orthopaedic surgeon respectively. Fair inter-rater agreement was found in 30° of flexion, κF = 0.29 (95% CI: 0.01 to 0.56), p = 0.044 and 90° of flexion, κF = 0.38 (95% CI: 0.10 to 0.66), p = 0.007. Almost perfect rater-device agreement was found in 30° of flexion, κC = 0.84 (95% CI: 0.52 to 1.15), p < 0.001. Moderate rater-device agreement was found in 30° and 90° combined, κC = 0.50 (95% CI: 0.13 to 0.86), p = 0.008. No significant intra-rater agreement was found. Conclusions Rater agreement reliability of the manual dial test is questionable. It has a fair inter-rater agreement in 30° and 90° of flexion

    A novel test for assessment of anterolateral rotatory instability of the knee: the tibial internal rotation test (TIR test)

    No full text
    Abstract Background Rotational instability of the knee may persist after anterior cruciate ligament (ACL) reconstruction, which may be due to insufficiency of anterolateral stabilizing structures. However, no reliable diagnostic tool or physical examination test is available for identifying patients with anterolateral rotatory instability (ALRI). As shown in cadaveric studies, static internal rotation of the knee is increased in higher flexion angles of the knee after severing the anterolateral structures. This might also be the case in patients with an ACL-deficient knee and concomitant damage to the anterolateral structures. The objective of this study is to assess anterolateral rotatory instability of the knee during physical examination with a tibial internal rotation test. Methods ACL-injured knees of 52 patients were examined by two examiners and side-to-side differences were compared. Both lower legs were internally rotated by applying manual internal rotation torque to both feet in prone position with the knees in 30°, 60° and 90° of flexion. For quantification of the amount of rotation in degrees, a torque adapter on a booth was used. Intra-rater, inter-rater and rater-device agreement were determined by calculating kappa (κ) for the tibial internal rotation test. Results Tibial internal rotation is increased in 19.2% of the patients with ACL injury according to the tibial internal rotation test. Good intra-rater agreement was found for the tibial internal rotation test, κC = 0.63 (95%CI -0.02-1.28), p = 0.015. Fair inter-rater agreement was found, κF = 0.29 (95%CI 0.02–0.57), p = 0.038. Good rater-device agreement was found, κC = 0.62 (95%CI 0.15–1.10), p = 0.001. Conclusion The tibial internal rotation test shows increased tibial internal rotation in a small amount of patients with ACL injury. Even though no gold standard for assessment of increased tibial internal rotation of the knee is available yet, the test can be of additional value. It can be used for assessment of internal rotatory laxity of the knee as part of ALRI in addition to the pivot shift test. No clinical implications should yet be based on this test alone

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between Mar

    Femoral Neck Shortening After Hip Fracture Fixation Is Associated With Inferior Hip Function : Results From the FAITH Trial

    No full text

    Nutzenbewertung von Trainingsinterventionen für die Sturzprophylaxe bei älteren Menschen - eine systematische Übersicht auf der Grundlage systematischer Übersichten

    No full text

    Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures

    No full text
    corecore