25 research outputs found
All-sky search for long-duration gravitational wave transients with initial LIGO
We present the results of a search for long-duration gravitational wave transients in two sets of data collected by the LIGO Hanford and LIGO Livingston detectors between November 5, 2005 and September 30, 2007, and July 7, 2009 and October 20, 2010, with a total observational time of 283.0 days and 132.9 days, respectively. The search targets gravitational wave transients of duration 10-500 s in a frequency band of 40-1000 Hz, with minimal assumptions about the signal waveform, polarization, source direction, or time of occurrence. All candidate triggers were consistent with the expected background; as a result we set 90% confidence upper limits on the rate of long-duration gravitational wave transients for different types of gravitational wave signals. For signals from black hole accretion disk instabilities, we set upper limits on the source rate density between 3.4×10-5 and 9.4×10-4 Mpc-3 yr-1 at 90% confidence. These are the first results from an all-sky search for unmodeled long-duration transient gravitational waves. © 2016 American Physical Society
All-sky search for long-duration gravitational wave transients with initial LIGO
We present the results of a search for long-duration gravitational wave transients in two sets of data collected by the LIGO Hanford and LIGO Livingston detectors between November 5, 2005 and September 30, 2007, and July 7, 2009 and October 20, 2010, with a total observational time of 283.0 days and 132.9 days, respectively. The search targets gravitational wave transients of duration 10-500 s in a frequency band of 40-1000 Hz, with minimal assumptions about the signal waveform, polarization, source direction, or time of occurrence. All candidate triggers were consistent with the expected background; as a result we set 90% confidence upper limits on the rate of long-duration gravitational wave transients for different types of gravitational wave signals. For signals from black hole accretion disk instabilities, we set upper limits on the source rate density between 3.4×10-5 and 9.4×10-4 Mpc-3 yr-1 at 90% confidence. These are the first results from an all-sky search for unmodeled long-duration transient gravitational waves. © 2016 American Physical Society
Recommended from our members
Impact of 24 hour continuous hypothermic perfusion on heart preservation by assessment of DNA damage and repair
Tepotinib in Non-Small-Cell Lung Cancer with MET Exon 14 Skipping Mutations
BACKGROUNDA splice-site mutation that results in a loss of transcription of exon 14 in the oncogenic driverMEToccurs in 3 to 4% of patients with non-small-cell lung cancer (NSCLC). We evaluated the efficacy and safety of tepotinib, a highly selective MET inhibitor, in this patient population.METHODSIn this open-label, phase 2 study, we administered tepotinib (at a dose of 500 mg) once daily in patients with advanced or metastatic NSCLC with a confirmedMETexon 14 skipping mutation. The primary end point was the objective response by independent review among patients who had undergone at least 9 months of follow-up. The response was also analyzed according to whether the presence of aMETexon 14 skipping mutation was detected on liquid biopsy or tissue biopsy.RESULTSAs of January 1, 2020, a total of 152 patients had received tepotinib, and 99 patients had been followed for at least 9 months. The response rate by independent review was 46% (95% confidence interval [CI], 36 to 57), with a median duration of response of 11.1 months (95% CI, 7.2 to could not be estimated) in the combined-biopsy group. The response rate was 48% (95% CI, 36 to 61) among 66 patients in the liquid-biopsy group and 50% (95% CI, 37 to 63) among 60 patients in the tissue-biopsy group; 27 patients had positive results according to both methods. The investigator-assessed response rate was 56% (95% CI, 45 to 66) and was similar regardless of the previous therapy received for advanced or metastatic disease. Adverse events of grade 3 or higher that were considered by investigators to be related to tepotinib therapy were reported in 28% of the patients, including peripheral edema in 7%. Adverse events led to permanent discontinuation of tepotinib in 11% of the patients. A molecular response, as measured in circulating free DNA, was observed in 67% of the patients with matched liquid-biopsy samples at baseline and during treatment.CONCLUSIONSAmong patients with advanced NSCLC with a confirmedMETexon 14 skipping mutation, the use of tepotinib was associated with a partial response in approximately half the patients.Peripheral edema was the main toxic effect of grade 3 or higher.Pathogenesis and treatment of chronic pulmonary disease