A calibration method for broad-bandwidth cavity enhanced absorption spectroscopy performed with supercontinuum radiation
An efficient calibration method has been developed for broad-bandwidth cavity enhanced absorption spectroscopy. The calibration is performed using phase shift cavity ring-down spectroscopy, which is conveniently implemented through use of an acousto-optic tunable filter (AOTF). The AOTF permits a narrowband portion of the SC spectrum to be scanned over the full high-reflectivity bandwidth of the cavity mirrors. After calibration the AOTF is switched off and broad-bandwidth CEAS can be performed with the same light source without any loss of alignment to the set-up. We demonstrate the merits of the method by probing transitions of oxygen molecules O-2 and collisional pairs of oxygen molecules (O-2)(2) in the visible spectral range
CONSORT Harms 2022 statement, explanation, and elaboration: updated guideline for the reporting of harms in randomized trials.
Randomized controlled trials remain the reference standard for healthcare research on effects of interventions, and the need to report both benefits and harms is essential. The Consolidated Standards of Reporting Trials (the main CONSORT) statement includes one item on reporting harms (i.e., all important harms or unintended effects in each group). In 2004, the CONSORT group developed the CONSORT Harms extension; however, it has not been consistently applied and needs to be updated. Here, we describe CONSORT Harms 2022, which replaces the CONSORT Harms 2004 checklist, and shows how CONSORT Harms 2022 items could be incorporated into the main CONSORT checklist. Thirteen items from the main CONSORT were modified to improve harms reporting. Three new items were added. In this article, we describe CONSORT Harms 2022 and how it was integrated into the main CONSORT checklist and elaborate on each item relevant to complete reporting of harms in randomized controlled trials. Until future work from the CONSORT group produces an updated checklist, authors, journal reviewers, and editors of randomized controlled trials should use the integrated checklist presented in this paper
GEANT4 : a simulation toolkit
Abstract Geant4 is a toolkit for simulating the passage of particles through matter. It includes a complete range of functionality including tracking, geometry, physics models and hits. The physics processes offered cover a comprehensive range, including electromagnetic, hadronic and optical processes, a large set of long-lived particles, materials and elements, over a wide energy range starting, in some cases, from 250 eV and extending in others to the TeV energy range. It has been designed and constructed to expose the physics models utilised, to handle complex geometries, and to enable its easy adaptation for optimal use in different sets of applications. The toolkit is the result of a worldwide collaboration of physicists and software engineers. It has been created exploiting software engineering and object-oriented technology and implemented in the C++ programming language. It has been used in applications in particle physics, nuclear physics, accelerator design, space engineering and medical physics. PACS: 07.05.Tp; 13; 2
Extent of non-publication in cohorts of studies approved by research ethics committees or included in trial registries
Background: The synthesis of published research in systematic reviews is essential when providing evidence to inform clinical and health policy decisionmaking. However, the validity of systematic reviews is threatened if journal publications represent a biased selection of all studies that have been conducted (dissemination bias). To investigate the extent of dissemination bias we conducted a systematic review that determined the proportion of studies published as peerreviewed journal articles and investigated factors associated with full publication in cohorts of studies (i) approved by research ethics committees (RECs) or (ii) included in trial registries. Copyright:Methods and Findings: Four bibliographic databases were searched for methodological research projects (MRPs) without limitations for publication year, language or study location. The searches were supplemented by handsearching the references of included MRPs. We estimated the proportion of studies published using prediction intervals (PI) and a random effects meta-analysis. Pooled odds ratios (OR) were used to express associations between study characteristics and journal publication. Seventeen MRPs (23 publications) evaluated cohorts of studies approved by RECs; the proportion of published studies had a PI between 22% and 72% and the weighted pooled proportion when combining estimates would be 46.2% (95% CI 40.2%-52.4%, I2594.4%). Twenty-two MRPs (22 publications) evaluated cohorts of studies included in trial registries; the PI of the proportion published ranged from 13% to 90% and the weighted pooled proportion would be 54.2% (95% CI 42.0%-65.9%, I2598.9%). REC-approved studies with statistically significant results (compared with those without statistically significant results) were more likely to be published (pooled OR 2.8; 95% CI 2.2-3.5). Phase-III trials were also more likely to be published than phase II trials (pooled OR 2.0; 95% CI 1.6- 2.5). The probability of publication within two years after study completion ranged from 7% to 30%.Conclusions: A substantial part of the studies approved by RECs or included in trial registries remains unpublished. Due to the large heterogeneity a prediction of the publication probability for a future study is very uncertain. Non-publication of research is not a random process, e.g., it is associated with the direction of study findings. Our findings suggest that the dissemination of research findings is biased
Cavity-enhanced direct frequency comb spectroscopy
Cavity-enhanced direct frequency comb spectroscopy combines broad spectral
bandwidth, high spectral resolution, precise frequency calibration, and
ultrahigh detection sensitivity, all in one experimental platform based on an
optical frequency comb interacting with a high-finesse optical cavity. Precise
control of the optical frequency comb allows highly efficient, coherent
coupling of individual comb components with corresponding resonant modes of the
high-finesse cavity. The long cavity lifetime dramatically enhances the
effective interaction between the light field and intracavity matter,
increasing the sensitivity for measurement of optical losses by a factor that
is on the order of the cavity finesse. The use of low-dispersion mirrors
permits almost the entire spectral bandwidth of the frequency comb to be
employed for detection, covering a range of ~10% of the actual optical
frequency. The light transmitted from the cavity is spectrally resolved to
provide a multitude of detection channels with spectral resolutions ranging
from a several gigahertz to hundreds of kilohertz. In this review we will
discuss the principle of cavity-enhanced direct frequency comb spectroscopy and
the various implementations of such systems. In particular, we discuss several
types of UV, optical, and IR frequency comb sources and optical cavity designs
that can be used for specific spectroscopic applications. We present several
cavity-comb coupling methods to take advantage of the broad spectral bandwidth
and narrow spectral components of a frequency comb. Finally, we present a
series of experimental measurements on trace gas detections, human breath
analysis, and characterization of cold molecular beams.Comment: 36 pages, 27 figure
CONSORT Harms 2022 statement, explanation, and elaboration: updated guideline for the reporting of harms in randomised trials
Randomised controlled trials remain the reference standard for healthcare research on effects of interventions, and the need to report both benefits and harms is essential. The Consolidated Standards of Reporting Trials (the main CONSORT) statement includes one item on reporting harms (ie, all important harms or unintended effects in each group). In 2004, the CONSORT group developed the CONSORT Harms extension; however, it has not been consistently applied and needs to be updated. Here, we describe CONSORT Harms 2022, which replaces the CONSORT Harms 2004 checklist, and shows how CONSORT Harms 2022 items could be incorporated into the main CONSORT checklist. Thirteen items from the main CONSORT were modified to improve harms reporting. Three new items were added. In this article, we describe CONSORT Harms 2022 and how it was integrated into the main CONSORT checklist, and elaborate on each item relevant to complete reporting of harms in randomised controlled trials. Until future work from the CONSORT group produces an updated checklist, authors, journal reviewers, and editors of randomised controlled trials should use the integrated checklist presented in this paper
CONSORT Harms 2022 statement, explanation, and elaboration: updated guideline for the reporting of harms in randomised trials
Randomised controlled trials remain the reference standard for healthcare research on effects of interventions, and the need to report both benefits and harms is essential. The Consolidated Standards of Reporting Trials (the main CONSORT) statement includes one item on reporting harms (ie, all important harms or unintended effects in each group). In 2004, the CONSORT group developed the CONSORT Harms extension; however, it has not been consistently applied and needs to be updated. Here, we describe CONSORT Harms 2022, which replaces the CONSORT Harms 2004 checklist, and shows how CONSORT Harms 2022 items could be incorporated into the main CONSORT checklist. Thirteen items from the main CONSORT were modified to improve harms reporting. Three new items were added. In this article, we describe CONSORT Harms 2022 and how it was integrated into the main CONSORT checklist, and elaborate on each item relevant to complete reporting of harms in randomised controlled trials. Until future work from the CONSORT group produces an updated checklist, authors, journal reviewers, and editors of randomised controlled trials should use the integrated checklist presented in this paper
The role of emotions on consumers’ satisfaction within the fitness context
Previous studies have suggested that consumption-related emotions are important to understand post-purchase
reactions. This study examines the relationship between fitness consumers’ emotions and overall satisfaction. After an
initial step of free-thought listing and content validity, followed by a pre-test, a survey was conducted among consumers
of five different fitness centers (n=786). The questionnaire included measures to assess positive and negative emotions,
as well as overall satisfaction with the fitness center. The results gathered through a structural equation model provide
evidence that negative emotion experienced by consumers impacts negatively overall satisfaction, while positive emotion
have a positive effect on overall satisfaction. These findings suggest managerial implications, such as the need to collect
consumers’ perceptions of both tangible and intangible aspects of the services, listen costumers’ opinions in a regular
basis, and provide regular training to staff members, in order to identify the triggers of positive emotions and contribute
to increased levels of overall satisfaction. Guidelines for future research within the fitness context are also suggested.Estudos precedentes sugerem
que as emoções relacionadas com o consumo são importantes para compreender as reações dos consumidores após a
compra. Este estudo analisa a relação entre as emoções dos consumidores de fitness e satisfação global. Depois de uma
etapa inicial de listagem de pensamento-livre e validade de conteúdo, seguido de um pré-teste, foi realizada uma pesquisa
entre os consumidores de cinco centros de fitness diferentes (n = 786). O questionário incluiu medidas para avaliar as
emoções positivas e negativas, bem como a satisfação global com o centro de fitness. Os resultados obtidos através de
um modelo de equações estruturais forneceram evidências de que as emoções negativas vivenciadas pelos consumidores
impactam negativamente a satisfação global, enquanto as emoções positivas têm um efeito positivo sobre a satisfação
global. Estes resultados sugerem implicações para os gestores, tais como a necessidade de recolher informação sobre a
perceção dos consumidores dos aspetos tangíveis e intangíveis dos serviços, ouvir regularmente as opiniões dos consumidores
e facultar formação regular aos colaboradores. Isto permitirá identificar os aspetos que desencadeiam emoções
positivas e contribuir para o aumento dos níveis de satisfação global. Orientações para futuras pesquisas no contexto de
fitness também são sugeridas.Sin financiación0.185 SJR (2015) Q3, 1090/1779 Medicine (miscellaneous); Q4, 177/229 Health (social science), 112/128 Sports scienceUE
Wholesale pricing in a small open economy
This paper addresses the empirical analysis of wholesale profit margins using data of the Dutch wholesale sector, 1986. At the heart of the analysis is the typical nature of wholesale production: wholesalers do not produce a tangible product, but offer a service capacity. This has an immediate impact on the identification, interprelation and measurement of determinants of profit variations. A model is set up to explain variations in wholesale profit margins, which is inspired by two widely applied approaches to industry pricing: the behavioural mark-up model and the marginalist price-cost model
- …