140 research outputs found
Reliability of limb alignment measurement for high tibial osteotomy with a navigation system
<p>Abstract</p> <p>Objective</p> <p>High tibial osteotomy (HTO) is one treatment option for young and active patients with unicompartmental osteoarthritis. The success of this procedure substantially depends on the degree of correction of the mechanical axis. Computer-assisted navigation systems are believed to improve the precision of axis correction through intraoperative real-time monitoring. This study investigates the accuracy of limb alignment measurements with a navigation system on a cadaver specimen.</p> <p>Materials and methods</p> <p>The measurements were performed on a well-preserved cadaver specimen with a mechanical leg axis of 4° varus. Data was collected during the HTO workflow. Repeated serial measurements were undertaken by four different surgeons. After these measurements, different landmarks were deliberately set at the wrong place to examine the influence of mistakes during registration.</p> <p>Results</p> <p>There was a high intra-and interobserver reliability with a mean mechanical leg axis of 3.9° ± 0.7° and a mean error of 0.6°. The grossly incorrect placement of landmarks for knee and ankle center resulted in an incorrect mechanical leg axis of 1° valgus up to 10° varus.</p> <p>Conclusion</p> <p>The computer-assisted navigation system provided precise information about the mechanical leg axis, irrespective of the observer's experience.</p
Functional outcome after open and arthroscopic Bankart repair for traumatic shoulder instability
<p>Abstract</p> <p>Purpose</p> <p>Both open and arthroscopic Bankart repair are established procedures in the treatment of anterior shoulder instability. While the open procedure is still considered as the "golden standard" functional outcome is supposed to be better in the arthroscopic procedure. The aim of this retrospective study was to compare the functional outcome between open and arthroscopic Bankart repair.</p> <p>Materials and methods</p> <p>In 199 patients a Bankart procedure with suture anchors was performed, either arthroscopically in presence of an detached, but not elongated capsulolabral complex (40) or open (159). After a median time of 31 months (12 to 67 months) 174 patients were contacted and agreed to follow-up, 135 after open and 39 after arthroscopic Bankart procedure.</p> <p>Results</p> <p>Re-dislocations occurred in 8% after open and 15% after arthroscopic Bankart procedure. After open surgery 4 of the 11 re-dislocations occurred after a new adequate trauma and 1 of the 6 re-dislocations after arthroscopic surgery. Re-dislocations after arthroscopic procedure occured earlier than after open Bankart repair. An external rotation lag of 20° or more was observed more often (16%) after open than after arthroscopic surgery (3%). The Rowe score demonstrated "good" or "excellent" functional results in 87% after open and in 80% patients after arthroscopic treatment.</p> <p>Conclusion</p> <p>In this retrospective investigation the open Bankart procedure demonstrated good functional results. The arthroscopic treatment without capsular shift resulted in a better range of motion, but showed a tendency towards more frequently and earlier recurrence of instability. Sensitive patient selection for arthroscopic Bankart repair is recommended especially in patients with more than five dislocations.</p
European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing.
Summary Introduction There is an ongoing debate about the optimal use of metal-on-metal (MoM) bearings in total hip replacement, since there are uncertainties about local and systemic adverse effects due to wear and corrosion of these bearings. Despite various national recommendations, efforts to achieve international harmonization of specific evidence-based recommendations for best practice are still lacking. Hypothesis An international consensus study group should be able to develop recommendations on the use and monitoring of MoM bearings, preferably at the European level, through a multidisciplinary approach, by integrating the perspectives of various stakeholders. Materials and methods Twenty-one experts representing three stakeholder groups and eight countries participated in this European consensus study, which consisted of a consensus meeting, subsequent structured discussion, and consensus voting. Results The current statement defines first of all benefits, local and systemic risks, as well as uncertain issues related to MoM bearings. Safety assessment after implantation of MoM comprises all patients. A closer follow-up is recommended for large head MoM (≥ 36 mm) and resurfacing. In these implants basic follow-up should consist of x-rays and metal ion measurement of cobalt in whole blood, performed with GF-AAS or ICP-MS. Clinical and/or radiographic abnormality as well as elevated ion levels needs additional imaging (ultrasound, CT-scan and/or MARS-MRI). Cobalt values less than 2 μg/L are probably devoid of clinical concern, the threshold value for clinical concern is expected to be within the range of 2–7 μg/L. Discussion This is the first multinational, interdisciplinary, and multiprofessional approach for developing a recommendation for the use and monitoring of MoM bearings in total hip replacement. The current recommendations are in partial agreement with previous statements regarding the extent of follow-up and imaging techniques. They however differ from previous communications regarding measurement of metal ions and especially the investigated medium, technique, and eventual threshold levels. Level of evidence Level V, expert opinion/agreement conference
Gene Expression of the Tumour Suppressor LKB1 Is Mediated by Sp1, NF-Y and FOXO Transcription Factors
The serine/threonine kinase LKB1 is a tumour suppressor that regulates multiple biological pathways, including cell cycle control, cell polarity and energy metabolism by direct phosphorylation of 14 different AMP-activated protein kinase (AMPK) family members. Although many downstream targets have been described, the regulation of LKB1 gene expression is still poorly understood. In this study, we performed a functional analysis of the human LKB1 upstream regulatory region. We used 200 base pair deletion constructs of the 5′-flanking region fused to a luciferase reporter to identify the core promoter. It encompasses nucleotides −345 to +52 relative to the transcription start site and coincides with a DNase I hypersensitive site. Based on extensive deletion and substitution mutant analysis of the LKB1 promoter, we identified four cis-acting elements which are critical for transcriptional activation. Using electrophoretic mobility shift assays as well as chromatin immunoprecipitations, we demonstrate that the transcription factors Sp1, NF-Y and two forkhead box O (FOXO) family members FOXO3 and FOXO4 bind to these elements. Overexpression of these factors significantly increased the LKB1 promoter activity. Conversely, small interfering RNAs directed against NF-Y alpha and the two FOXO proteins greatly reduced endogenous LKB1 expression and phosphorylation of LKB1's main substrate AMPK in three different cell lines. Taken together, these results demonstrate that Sp1, NF-Y and FOXO transcription factors are involved in the regulation of LKB1 transcription
- …