23 research outputs found

    Cryo-balloon reconstruction from two views

    Full text link
    Atrial fibrillation is a major cause of stroke. Its treatment is performed under fluoroscopic image guidance. Augmented fluoroscopy has become a useful tool during the ablation pro-cedure for navigation under X-ray. Unfortunately, current navigation systems do not provide tools to localize and visu-alize a cryo-balloon catheters in 3-D. This is why we present a new approach to reconstruct the cryo-ballon catheter, mod-eled as a sphere, from two views. The reconstruction result can then be overlayed onto live fluoroscopic images during the procedure. In simulation studies, we compared our tech-nique to a reference method. While both methods worked equally well on noise-free data, we found our method more reliable if the input data was affected by noise. For example, in the presence of noise with a standard deviation of 4 mm, our maximum 3-D reconstruction error was less than 1 mm

    The Localization Transition of the Two-Dimensional Lorentz Model

    Full text link
    We investigate the dynamics of a single tracer particle performing Brownian motion in a two-dimensional course of randomly distributed hard obstacles. At a certain critical obstacle density, the motion of the tracer becomes anomalous over many decades in time, which is rationalized in terms of an underlying percolation transition of the void space. In the vicinity of this critical density the dynamics follows the anomalous one up to a crossover time scale where the motion becomes either diffusive or localized. We analyze the scaling behavior of the time-dependent diffusion coefficient D(t) including corrections to scaling. Away from the critical density, D(t) exhibits universal hydrodynamic long-time tails both in the diffusive as well as in the localized phase.Comment: 13 pages, 7 figures

    Echo-driven V-V optimization determines clinical improvement in non responders to cardiac resynchronization treatment

    Get PDF
    Echocardiography plays an integral role in the detection of mechanical dyssynchrony in patients with congestive heart failure and in predicting beneficial response to cardiac resynchronization treatment. In patients who derive sup-optimal benefit from biventricular pacing, optimization of atrioventricular delay post cardiac resynchronization treatment has been shown to improve cardiac output. Some recent reports suggest that sequential ventricular pacing may further improve cardiac output. The mechanism whereby sequential ventricular pacing improves cardiac output is likely improved inter and possibly intraventricular synchrony, however these speculations have not been confirmed. In this report we describe the beneficial effect of sequential V-V pacing on inter and intraventricular synchrony, cardiac output and mitral regurgitation severity as the mechanisms whereby sequential biventricular pacing improves cardiac output and functional class in 8 patients who had derived no benefit or had deteriorated after CRT. Online tissue Doppler imaging including tissue velocity imaging, tissue synchronization imaging and strain and strain rate imaging were used in addition to conventional pulsed wave and color Doppler during sequential biventricular pacemaker programming

    Effects of porous confinement on the structural properties of the Gaussian core model

    No full text
    We have investigated the structural properties of a fluid in which particles, interacting via soft potentials, are imbibed into a disordered porous structure built up by soft particles. Using a Gaussian potential for all interactions involved, we determine via Monte Carlo simulations and integral-equation theory the fluid-fluid, fluid-matrix, connected, and blocked structure factors. Within the explored range of state parameters, the fluid-fluid structure factors display a distinct pre-peak, which we identify as a fingerprint of the structure of the matrix. We show that this feature at low wave-vectors arises from contributions of blocked correlations to the fluid-fluid structure factor. We argue that a similar feature may be found also in systems in which particles interact via harshly repulsive potentials. On the other hand, the variation of the main peak of the fluid-fluid structure factor resembles the behaviour of the equilibrium Gaussian core model fluid. In particular, the height of the main peak changes non-monotonically with increasing fluid density at fixed matrix density. Finally, we analyse the effect of a mismatch between the temperature of the fluid and the temperature of the matrix on the structural properties of the system
    corecore