10,607 research outputs found

    Artifact Rejection Methodology Enables Continuous, Noninvasive Measurement of Gastric Myoelectric Activity in Ambulatory Subjects.

    Get PDF
    The increasing prevalence of functional and motility gastrointestinal (GI) disorders is at odds with bottlenecks in their diagnosis, treatment, and follow-up. Lack of noninvasive approaches means that only specialized centers can perform objective assessment procedures. Abnormal GI muscular activity, which is coordinated by electrical slow-waves, may play a key role in symptoms. As such, the electrogastrogram (EGG), a noninvasive means to continuously monitor gastric electrical activity, can be used to inform diagnoses over broader populations. However, it is seldom used due to technical issues: inconsistent results from single-channel measurements and signal artifacts that make interpretation difficult and limit prolonged monitoring. Here, we overcome these limitations with a wearable multi-channel system and artifact removal signal processing methods. Our approach yields an increase of 0.56 in the mean correlation coefficient between EGG and the clinical "gold standard", gastric manometry, across 11 subjects (p < 0.001). We also demonstrate this system's usage for ambulatory monitoring, which reveals myoelectric dynamics in response to meals akin to gastric emptying patterns and circadian-related oscillations. Our approach is noninvasive, easy to administer, and has promise to widen the scope of populations with GI disorders for which clinicians can screen patients, diagnose disorders, and refine treatments objectively

    Not All Children with Cystic Fibrosis Have Abnormal Esophageal Neutralization during Chemical Clearance of Acid Reflux.

    Get PDF
    PurposeAcid neutralization during chemical clearance is significantly prolonged in children with cystic fibrosis, compared to symptomatic children without cystic fibrosis. The absence of available reference values impeded identification of abnormal findings within individual patients with and without cystic fibrosis. The present study aimed to test the hypothesis that significantly more children with cystic fibrosis have acid neutralization durations during chemical clearance that fall outside the physiological range.MethodsPublished reference value for acid neutralization duration during chemical clearance (determined using combined impedance/pH monitoring) was used to assess esophageal acid neutralization efficiency during chemical clearance in 16 children with cystic fibrosis (3 to <18 years) and 16 age-matched children without cystic fibrosis.ResultsDuration of acid neutralization during chemical clearance exceeded the upper end of the physiological range in 9 of 16 (56.3%) children with and in 3 of 16 (18.8%) children without cystic fibrosis (p=0.0412). The likelihood ratio for duration indicated that children with cystic fibrosis are 2.1-times more likely to have abnormal acid neutralization during chemical clearance, and children with abnormal acid neutralization during chemical clearance are 1.5-times more likely to have cystic fibrosis.ConclusionSignificantly more (but not all) children with cystic fibrosis have abnormally prolonged esophageal clearance of acid. Children with cystic fibrosis are more likely to have abnormal acid neutralization during chemical clearance. Additional studies involving larger sample sizes are needed to address the importance of genotype, esophageal motility, composition and volume of saliva, and gastric acidity on acid neutralization efficiency in cystic fibrosis children

    Multiple exciton generation in nano-crystals revisited: Consistent calculation of the yield based on pump-probe spectroscopy

    Get PDF
    Multiple exciton generation (MEG) is a process in which more than one exciton is generated upon the absorption of a high energy photon, typically higher than two times the band gap, in semiconductor nanocrystals. It can be observed experimentally using time resolved spectroscopy such as the transient absorption measurements. Quantification of the MEG yield is usu- ally done by assuming that the bi-exciton signal is twice the signal from a single exciton. Herein we show that this assumption is not always justified and may lead to significant errors in the estimated MEG yields. We develop a methodology to determine proper scaling factors to the signals from the transient absorption experiments. Using the methodology we find modest MEG yields in lead chalcogenide nanocrystals including the nanorods

    Electron impact excitation cross sections for allowed transitions in atoms

    Full text link
    We present a semiempirical Gaunt factor for widely used Van Regemorter formula [Astrophys. J. 136, 906 (1962)] for the case of allowed transitions in atoms with the LS coupling scheme. Cross sections calculated using this Gaunt factor agree with measured cross sections to within the experimental error.Comment: RevTeX, 3 pages, 10 PS figures, 2 PS tables, submitted to Phys. Rev.

    Deep sub-threshold Ξ\Xi^- production in Ar+KCl reactions at 1.76A GeV

    Full text link
    We report first results on a deep sub-threshold production of the doubly strange hyperon Ξ\Xi^- in a heavy-ion reaction. At a beam energy of 1.76A GeV the reaction Ar+KCl was studied with the High Acceptance Di-Electron Spectrometer (HADES) at SIS18/GSI. A high-statistics and high-purity Λ\Lambda sample was collected, allowing for the investigation of the decay channel ΞΛπ\Xi^- \to \Lambda \pi^-. The deduced Ξ/(Λ+Σ0)\Xi^-/(\Lambda+\Sigma^0) production ratio of (5.6±1.21.7+1.8)103(5.6 \pm 1.2 ^{+1.8}_{-1.7})\cdot 10^{-3} is significantly larger than available model predictions.Comment: 4 pages, including 4 figure

    In-Medium Effects on K0 Mesons in Relativistic Heavy-Ion Collisions

    Full text link
    We present the transverse momentum spectra and rapidity distributions of π\pi^{-} and KS0^0_S in Ar+KCl reactions at a beam kinetic energy of 1.756 A GeV measured with the spectrometer HADES. The reconstructed KS0^0_S sample is characterized by good event statistics for a wide range in momentum and rapidity. We compare the experimental π\pi^{-} and KS0^0_S distributions to predictions by the IQMD model. The model calculations show that KS0^0_S at low tranverse momenta constitute a particularly well suited tool to investigate the kaon in-medium potential. Our KS0^0_S data suggest a strong repulsive in-medium K0^0 potential of about 40 MeV strength.Comment: 10 pages, 10 figures, accepted by Phys. Rev.

    Utility of repeat cytological assessment of thyroid nodules initially classified as benign: clinical insights from multidisciplinary care in an Irish tertiary referral centre.

    Get PDF
    BACKGROUND: Fine needle aspiration biopsy (FNAB) is the tool of choice for evaluating thyroid nodules with the majority classified as benign following initial assessment. However, concern remains about false negative results and some guidelines have recommended routine repeat aspirates. We aimed to assess the utility of routine repeat FNAB for nodules classified as benign on initial biopsy and to examine the impact of establishing a multidisciplinary team for the care of these patients. METHODS: We performed a retrospective review of 400 consecutive patients (413 nodules) who underwent FNAB of a thyroid nodule at our hospital between July 2008 and July 2011. Data recorded included demographic, clinical, histological and radiological variables. RESULTS: Three hundred and fifty seven patients (89 %) were female. Median follow-up was 5.5 years. Two hundred and fifty eight (63 %) nodules were diagnosed as benign. The rate of routine repeat biopsy increased significantly over the time course of the study (p for trend = 0.012). Nine Thy 2 nodules were classified differently on the basis of routine repeat biopsy; one patient was classified as malignant on repeat biopsy and was diagnosed with papillary thyroid carcinoma. Eight were classified as a follicular lesions on repeat biopsy-six diagnosed as benign following lobectomy; two declined lobectomy and were followed radiologically with no nodule size increase. CONCLUSIONS: The false negative rate of an initial benign cytology result, from a thyroid nodule aspirate, is low. In the setting of an experienced multidisciplinary thyroid team, routine repeat aspiration is not justified

    An upper limit on hypertriton production in collisions of Ar(1.76 AGeV)+KCl

    Full text link
    A high-statistic data sample of Ar(1.76 AGeV)+KCl events recorded with HADES is used to search for a hypertriton signal. An upper production limit per centrality-triggered event of 1.041.04 x 10310^{-3} on the 3σ3\sigma level is derived. Comparing this value with the number of successfully reconstructed Λ\Lambda hyperons allows to determine an upper limit on the ratio NΛ3H/NΛN_{_{\Lambda}^3H}/N_{\Lambda}, which is confronted with statistical and coalescence-type model calculations
    corecore