228 research outputs found
Discovery of Seven Companions To Intermediate-Mass Stars With Extreme Mass Ratios in the Scorpius-Centaurus Association
We report the detection of seven low-mass companions to intermediate-mass stars (SpT B/A/F; M similar to 1.5-4.5M(circle dot)) in the Scorpius-Centaurus (Sco-Cen) Association using nonredundant aperture masking interferometry. Our newly detected objects have contrasts Delta L' approximate to 4-6, corresponding to masses as low as similar to 20 M-Jup and mass ratios of q approximate to 0.01-0.08, depending on the assumed age of the target stars. With projected separations rho approximate to 10-30 AU, our aperture masking detections sample an orbital region previously unprobed by conventional adaptive optics imaging of intermediate-mass Sco-Cen stars covering much larger orbital radii (similar to 30-3000 AU). At such orbital separations, these objects resemble higher-mass versions of the directly imaged planetary mass companions to the 10-30 Myr, intermediate-mass stars HR 8799, beta Pictoris, and HD 95086. These newly discovered companions span the brown dwarf desert, and their masses and orbital radii provide a new constraint on models of the Formation of low-mass stellar and substellar companions to intermediate-mass stars.NASA through the Sagan Fellowship ProgramNSF Astronomy and Astrophysics Postdoctoral Fellowship AST-1203023Clay FellowshipNASA through Hubble Fellowship 51257.01AURA, Inc., for NASA NAS 5-26555W. M. Keck FoundationAstronom
Duration of tooth alignment with fixed appliances: A systematic review and meta-analysis
INTRODUCTION
A key goal of orthodontic treatment with fixed appliances is alignment of the dentition, and this remains a commonly selected outcome in clinical studies investigating orthodontic tooth movement. This systematic review has evaluated treatment duration to achieve alignment of the mandibular dentition using fixed appliances.
METHODS
Systematic literature searches without restrictions were undertaken in 9 databases for randomized clinical trials (RCTs) assessing duration and rate of tooth alignment using fixed appliances with or without treatment adjuncts published up to January 2021. After duplicate study selection, data extraction, and risk of bias assessment according to Cochrane, random-effects meta-analyses of aggregate data, and individual patient data were conducted.
RESULTS
Thirty-five trials were included with 2258 participants (39% male; mean age 17.8 years), giving a pooled duration to achieve whole-arch alignment of the mandibular dentition of 263.0 days (4 trials; 95% confidence interval [CI], 186.7-339.4 days) and incisor alignment in the mandibular arch of 100.7 days (9 trials; 95% CI, 84.1-117.4 days). Surgical-assisted orthodontics was associated with reduced duration of incisor alignment: mean difference of 44.3 days less (4 trials; 95% CI, 20.0-68.9 days; P <0.001; high quality of evidence), whereas subgroup and meta-regression analyses indicated significant effects of baseline crowding and premolar extractions. Individual patient data analysis from 3 RCTs indicated that for each additional participant age year, whole-arch alignment of the mandibular dentition took 13.7 days longer (3 trials; 95% CI, 7.7-17.7 days; P <0.001) and for each additional mm of irregularity, 17.5 days more were needed (2 trials; 95% CI, 9.8-25.2 days; P <0.001).
CONCLUSIONS
Patient and treatment-related characteristics can significantly affect the duration of tooth alignment and should be taken into account both clinically and when designing trial outcomes. Future research studies investigating rates of orthodontic tooth alignment would benefit from adequate sample sizes and a more consistent methodology in outcome assessment. Data in this systematic review provides a basis for appropriate trial design for future RCTs investigating the rate of orthodontic tooth alignment with fixed appliances
Microbiological assessment of aerosol generated during debond of fixed orthodontic appliances
Introduction The aims of this study were to describe bacterial load and diversity of the aerosol created during enamel cleanup after the removal of fixed orthodontic appliances and to assess the effect of a preprocedural mouth rinse. Methods The study involved the sampling of ambient air adjacent to the patient's mouth during adhesive removal using a slow-speed handpiece and a spiral fluted tungsten carbide bur without water irrigation. Sampling was carried out during enamel cleanup with or without a preprocedural mouth rinse of either sterile water or chlorhexidine. Airborne particles were collected using a viable inertial impactor simulating the human respiratory tree. The bacteria collected were analyzed using both culture and molecular techniques. Results Bacteria produced during debond and enamel cleanup can reach all levels of the respiratory tree. The use of a preprocedural mouth rinse, either sterile water or chlorhexidine, increased the numbers and diversity of the bacteria in the air. Conclusions When using a slow-speed handpiece and a spiral fluted tungsten carbide bur for enamel cleanup after orthodontic treatment, the bacterial load and diversity of the aerosol produced are lower when a preprocedural mouth rinse is not used.</p
- …