101 research outputs found

    Содержание и состав органических соединений в отделяющихся озерах в Антарктике и Арктике

    Get PDF
    The results of long-term studies of organic compounds in separated water bodies in two regions: Lake Stepped, Prydz Bay, Commonwealth Sea, (Antarctica) and lakes of the periphery of the Kandalaksha Gulf of the White Sea (the Arctic) are presented. It is established that the eutrophication of these reservoirs largely depends on the connection of these lakes with the sea. Coastal anthropogenic activity affects to a lesser extent. The restoration of the ecosystem of these lakes occurs at the launch of sea waters. The greatest differences between organic compounds in the Arctic and Antarctic waters are established in hydrocarbons. In Antarctica, due to the lack of vegetation, alkanes are dominated by autochthonous compounds, and in the Arctic along with autochthonous, allochthonous.Представлены результаты многолетних исследований органических соединений в отделяющихся водоемах в двух районах: в озере Степпед, залив Прюдс, море Содружества (Антарктика) и в озерах периферии Кандалакшского залива Белого моря (Арктика). Установлено, что эвтрофирование водоемов в значительной степени зависит от связи этих озер с морем. Восстановление экосистемы озер происходит при поступлении морских вод. Прибрежная антропогенная деятельность влияет в меньшей степени. Наибольшие различия между органическими соединениями в арктических и антарктических озерах установлены в составе углеводородов. В Антарктике, из-за отсутствия растительности, в составе алканов преобладают автохтонные соединения, а в Арктике, наряду с автохтонными, аллохтонные

    Evaluation of the applicability of immunochromatography to the identification of live plague vaccines and the tularaemia allergen (Tularin)

    Get PDF
    The regulatory standards require that the identification of live plague vaccines and the liquid tularaemia allergen (Tularin) should be performed by immunofluorescence. A major drawback of the recommended method is its labour intensive nature. However, immunochromatography represents an alternative method that offers a number of advantages, including rapid testing and easy result interpretation. The aim of the study was to assess the applicability of immunochromatography to the identification of live plague vaccines and the liquid tularaemia allergen (Tularin).Materials and methods. The authors performed identification tests using samples of the pharmacopoeia standard for live plague vaccines, three commercial batches of a live plague vaccine, and two batches of the liquid tularaemia allergen (Tularin). These samples were tested using immunochromatographic assay (ICA) reagent kits for rapid detection and identification of Yersinia pestis (ICA System for Y. pestis) and Francisella tularensis (ICA System for F. tularensis) manufactured by the State Scientific Center for Applied Microbiology and Biotechnology.Results. The findings show that immunochromatography is an effective, rapid, and species-specific method to confirm the presence of Y. pestis in a sample of a live plague vaccine or F. tularensis in a sample of the liquid tularaemia allergen (Tularin). To perform identification tests by immunochromatography, the authors recommend diluting live plague vaccine samples to a concentration of 109 bacterial cells/mL and using undiluted samples of the liquid tularaemia allergen (Tularin).Conclusions. The study results may support the inclusion of ICA into the regulatory standards for live plague vaccines and the liquid tularaemia allergen (Tularin) as an alternative identification method

    Using Shewhart charts to monitor quality characteristics of preventive vaccines for tuberculosis

    Get PDF
    Scientific relevance. The quality of medicinal products, particularly vaccines, is contingent on the stability of the manufacturing process at all stages, which can be evaluated using Shewhart charts for data obtained by monitoring the quality attributes of interest.Aim. This study evaluated the stability of the quality and manufacturing processes of the BCG and BCG-M tuberculosis vaccines using Shewhart charts.Materials and methods. This study focused on samples of the BCG tuberculosis vaccine and the BCG-M tuberculosis vaccine, a less reactogenic alternative for primary immunisation. Both vaccines were released to the market in 2019–2022. The quality of samples was assessed for stability based on their potency and total bacterial count, which are the key parameters for immunogenicity evaluation. These quality parameters were compared using test results submitted by the manufacturer and obtained at the testing centre. The authors plotted individuals charts (X-charts) and moving range charts (R-charts) in accordance with national standards GOST R 50779.42-99 and GOST R ISO 7870-2-2015.Results. The quality of the BCG and BCG-M vaccines remained stable during the entire follow-up period (2019–2022). For some periods, the retrospective analysis of R- and X-charts revealed characteristic trends meeting special cause criteria. The Pearson correlation coefficient (r) between the data submitted by the manufacturer and the data obtained at the testing centre ranged from 0.2 to 0.8.Conclusions. The Shewhart charts demonstrated that the quality parameters of the BCG and BCG-M tuberculosis vaccines tested in 2019–2022 were stable. These vaccines had stable manufacturing processes, as shown by the R- and X-charts. However, the warning signs indicated that additional measures should be taken to standardise the manufacturing processes. The findings suggest that Shewhart charts may be recommended for monitoring the production and quality of tuberculosis vaccines

    Certification of a New Batch of the Industry Reference Standard for the Control of Specific Activity and Thermal Stability of Live Plague Vaccine

    Get PDF
    In accordance with the State Pharmacopoeia (SPh) requirements for live plague vaccine, a reference standard has to be used when testing the specific activity and thermal stability of plague vaccine commercial batches in order to assess the consistency and acceptability of the test results. Since there is no international reference standard for plague vaccine, the certification of a new batch of the industry reference standard (IRS) of live plague vaccine in terms of the above-mentioned quality parameters is an urgent challenge. Therefore, a certification programme for the industry reference standard was developed that establishes the design and scope of testing required to obtain statistically significant results. A candidate IRS was represented by a commercial batch of the product meeting the specification requirements for live plague vaccine. The certification parameters were: «Specific activity: microbial cell concentration», «Specific activity: live microbial cell percentage» and «Thermal stability». The article presents the results of the certification of a new batch of the live plague vaccine IRS, detailed evaluation of the candidate IRS in terms of: «Average weight and uniformity of weight», «Loss on drying», and statistical interpretation of the test results. It also summarises the results of the product testing in terms of «Specific activity: immunogenicity». The results of application of the previous batch of the live plague vaccine IRS (OSO 42-28-392-2013) and the results of monitoring the stability of its certification parameters demonstrated that the IRS shelf life could be extended by 6 months relative to the established period (from 2 to 2.5 years). All the certified and additional characteristics are reflected in the official documents for the scientific/technological product — live plague vaccine IRS, OSO 42-28-392-2017: passport, labelling and patient information leaflet

    Перспективы совершенствования экспертизы качества вакцины бруцеллезной живой по показателю «Специфическая активность»

    Get PDF
    Prophylactic immunisation against brucellosis is part of the National Immunisation Schedule for Epidemic Settings. The immunisation is performed with a live vaccine—a lyophilized suspension of the Brucella abortus strain 19 BА in a stabilizing medium. The paper presents the results of quality evaluation of 9 batches of live brucellosis vaccine that were submitted to the Testing Centre for Evaluation of Medicinal Immunobiological Products’ Quality of the Federal State Budgetary Institution “Scientific Centre for Expert Evaluation of Medicinal Products” of the Ministry of Health of the Russian Federation for assessment of the product’s compliance with the established specifications. The paper also presents the results of evaluation of the passport information provided by the manufacturer for these batches. There is no doubt about the need for objective quality evaluation of brucellosis vaccines as well as about the significance of its improvement.The aim of study was to assess the prospects for improving quality evaluation of live brucellosis vaccines in terms of Specific activity (concentration of microbial cells, number of living microbial cells, number of cutaneous doses).Materials and methods: specific activity (concentration of microbial cells and number of living microbial cells) was determined by visual and microbiological methods using the industrial reference standard of brucellosis vaccine OSO 42-28-396-2018, batch 6 and the bacterial suspension of the Brucella abortus strain 19 BА acquired from the joint stock company Scientific and Production Association “Microgen” in 2016. The number of cutaneous doses in the brusellosis vaccine was determined by the calculation method. Statistical processing of the results was performed using Microsoft Excel.Results: there was a mismatch between the brucella concentration coefficient of 1.7×109 microbial cells/mL determined by comparison with the industrial reference standard of bacterial suspension turbidity, 10 IU and the actual concentration of microbial cells obtained in the study. According to preliminary results, the brucella concentration coefficient corresponding to the industrial reference standard of bacterial suspension turbidity, 10 IU can reach 3.0×109 microbial cells/mL.Conclusions: the obtained results can serve as a basis for amending the data on the brucella concentration coefficient in the Passport and the Instructions for use of the industrial reference standard of bacterial suspension turbidity, 10 IU, as well as the Specific activity section (concentration of microbial cells, number of living microbial cells, number of cutaneous doses) of the established specifications for the brucellosis vaccine. Before amending the information on the brucella concentration corresponding to 10 IU in the Passport and the Instructions for use of the reference standard of bacterial suspension turbidity (OSO 42-28-85P), additional studies should be performed with other types of brucella.Профилактическая иммунизация против бруцеллеза входит в Национальный календарь прививок по эпидемическим показаниям. Для иммунизации людей применяется живая вакцина, представляющая собой лиофилизированную взвесь вакцинного штамма Brucella abortus 19 BА в стабилизирующей среде. В статье представлены результаты анализа качества 9 серий вакцины бруцеллезной живой, поступивших в Испытательный центр экспертизы качества МИБП ФГБУ «НЦЭСМП» Минздрава России для оценки соответствия препарата нормативным требованиям, а также анализ паспортных данных предприятия-производителя на эти серии. Необходимость проведения объективной экспертизы качества вакцины бруцеллезной, а также актуальность ее совершенствования не вызывают сомнений.Цель работы: оценка перспективы совершенствования экспертизы качества вакцины бруцеллезной живой по показателю «Специфическая активность» (концентрация микробных клеток, количество живых микробных клеток, количество накожных доз).Материалы и методы: специфическую активность (концентрацию микробных клеток, количество живых микробных клеток) определяли визуальным и микробиологическим методами на образцах ОСО 42-28-396-2018 вакцины бруцеллезной серии 6 и на бактериальной взвеси вакцинного штамма Brucella abortus 19 BА, полученного из АО «НПО «Микроген» в 2016 г. Количество накожных доз в вакцине бруцеллезной определяли расчетным методом. Статистическая обработка результатов была выполнена с помощью программы Microsoft Excel.Результаты: установлено несоответствие коэффициента концентрации бруцелл 1,7×109 м.к./мл по ОСО мутности бактериальных взвесей 10 МЕ фактическим данным, полученным в результате проведенных исследований. Предварительный коэффициент концентрации бруцеллезного микроба по ОСО мутности бактериальных взвесей 10 МЕ может достигать 3,0×109 м.к./мл.Выводы: полученные результаты могут послужить основанием для внесения изменения в паспорт и инструкцию по применению ОСО мутности бактериальных взвесей 10 МЕ по коэффициенту концентрации бруцеллезного микроба и в требования нормативной документации на вакцину бруцеллезную по показателю качества «Специфическая активность» (концентрация микробных клеток, количество живых микробных клеток, количество накожных доз). Для внесения соответствующих изменений по концентрации бруцелл, эквивалентной 10 МЕ, в паспорт и инструкцию по применению на ОСО мутности бактериальных взвесей (ОСО 42-28-85П) необходимо провести дополнительные испытания на других видах бруцелл

    Теоретическое и экспериментальное обоснование перспективных методов экспертизы качества вакцины сибиреязвенной живой

    Get PDF
    Preventive immunisation against anthrax is carried out in accordance with the national Immunisation Schedule for Epidemic Settings. The vaccination is performed using a live vaccine—a freeze-dried suspension of Bacillus anthracis STI-1 vaccine strain spores in a stabilizing media. Improvement of the quality control of immunobiological medicines is a pressing issue and an integral part of the quality management system. The aim of study was to streamline quality control of live anthrax vaccine in terms of the following test parameters: identification and specific activity (total spore concentration). Materials and methods: identification and specific activity (total spore concentration) tests were performed for samples of live anthrax vaccine, batch 266, produced by the 48 Central Scientific Research Institute. The identification test was performed using the B. anthracis immunochromatography test kit for express detection and identification of anthrax pathogen spores produced by the State Research Center for Applied Microbiology and Biotechnology (Obolensk). The specific activity (total spore concentration) was assessed by the visual method and calculated in the Goryaev chamber using the industry reference standard of bacterial suspension turbidity equivalent to 10 IU—OSO 42-28-85 (by the Scientific Centre for Expert Evaluation of Medicinal Products). The number of live spores in live anthrax vaccine was determined by the microbiological method (by inoculating media). The statistical processing of the results was performed using Excel and Statistica 10.0. Results: the authors provided theoretical and experimental substantiation to support the feasibility of using immunochromatography as an alternative identification test method for live anthrax vaccine. Test samples dilutions of 108 microbial cells per millilitre and 109 microbial cells per millilitre are used in the test. The authors developed a test procedure for determination of the total spore concentration (specific activity) in live anthrax vaccine using an industry reference standard of turbidity equivalent to 10 IU, and proposed a formula for calculation of the total spore concentration. Conclusions: the developed test procedures could be recommended for inclusion in the live anthrax vaccine specification files as alternative methods of quality control. Вакцинация против сибирской язвы проводится в соответствии с национальным Календарем профилактических прививок по эпидемическим показаниям. Для иммунизации людей применяется живая вакцина, представляющая собой лиофилизированную взвесь спор вакцинного штамма Вacillus anthracis СТИ-1 в стабилизирующей среде. Усовершенствование контроля качества иммунобиологических лекарственных препаратов посредством внедрения современных стандартных методов контроля является актуальной и неотъемлемой частью системы менеджмента качества. Цель работы: совершенствование экспертизы качества вакцины сибиреязвенной живой по показателю «Подлинность» и «Специфическая активность» (общая концентрация спор). Материалы и методы: испытание по показателям качества «Подлинность» и «Специфическая активность» (общая концентрация спор) проводили на образцах вакцины сибиреязвенной живой серии 266 производства ФГБУ «48 ЦНИИ» Минобороны России. Исследование иммунохроматографическим методом показателя качества вакцины «Подлинность» проводили с помощью набора реагентов иммунохроматографическая тест-система для экспресс-выявления и идентификации спор возбудителя сибирской язвы «ИХ тест-система B. anthracis» производства ФГБУ «ГНЦ ПМБ» Роспотребнадзора (г. Оболенск); контроль показателя качества вакцины «Специфическая активность» (общая концентрация спор) проводили визуальным и расчетным методами с применением камеры Горяева и отраслевого стандартного образца (ОСО) мутности бактериальных взвесей 10 МЕ — ОСО 42-28-85 (ФГБУ «НЦЭСМП» Минздрава России); испытание по показателю качества «Специфическая активность» (количество живых спор) сибиреязвенной вакцины проводили микробиологическим методом (посевом на питательные среды). Статистическая обработка результатов была выполнена с помощью программы Microsoft Excel и Statistica 10.0. Результаты: теоретически обоснована и экспериментально доказана возможность применения иммунохроматографического метода как альтернативного для оценки показателя «Подлинность» вакцины сибиреязвенной живой. При проведении данного испытания препарат следует разводить до концентраций 108 и 109 м.к./мл. Разработана методика определения общей концентрации спор (показатель «Специфическая активность») вакцины сибиреязвенной живой с применением ОСО мутности бактериальных взвесей 10 МЕ. Предложена формула расчета общей концентрации спор в вакцине. Вывод: предложенные методики экспертизы качества вакцины сибиреязвенной живой могут быть рекомендованы для включения в нормативную документацию в качестве альтернативных

    Оценка возможности применения иммунохроматографического метода для экспертизы качества вакцины чумной живой и аллергена туляремийного (Тулярина) по показателю «Подлинность»

    Get PDF
    The regulatory standards require that the identification of live plague vaccines and the liquid tularaemia allergen (Tularin) should be performed by immunofluorescence. A major drawback of the recommended method is its labour intensive nature. However, immunochromatography represents an alternative method that offers a number of advantages, including rapid testing and easy result interpretation. The aim of the study was to assess the applicability of immunochromatography to the identification of live plague vaccines and the liquid tularaemia allergen (Tularin).Materials and methods. The authors performed identification tests using samples of the pharmacopoeia standard for live plague vaccines, three commercial batches of a live plague vaccine, and two batches of the liquid tularaemia allergen (Tularin). These samples were tested using immunochromatographic assay (ICA) reagent kits for rapid detection and identification of Yersinia pestis (ICA System for Y. pestis) and Francisella tularensis (ICA System for F. tularensis) manufactured by the State Scientific Center for Applied Microbiology and Biotechnology.Results. The findings show that immunochromatography is an effective, rapid, and species-specific method to confirm the presence of Y. pestis in a sample of a live plague vaccine or F. tularensis in a sample of the liquid tularaemia allergen (Tularin). To perform identification tests by immunochromatography, the authors recommend diluting live plague vaccine samples to a concentration of 109 bacterial cells/mL and using undiluted samples of the liquid tularaemia allergen (Tularin).Conclusions. The study results may support the inclusion of ICA into the regulatory standards for live plague vaccines and the liquid tularaemia allergen (Tularin) as an alternative identification method.Определение показателя качества «Подлинность», согласно требованиям нормативной документации на вакцину чумную живую и аллерген туляремийный жидкий (Тулярин), проводится иммунофлуоресцентным методом, однако серьезным недостатком метода является его трудоемкость. Альтернативным методом испытания данных препаратов является иммунохроматографический (ИХ) метод, обладающий рядом преимуществ, в том числе высокой скоростью проведения испытания и простотой учета результатов.Цель работы: оценка возможности применения иммунохроматографического метода для экспертизы качества вакцины чумной живой и аллергена туляремийного (Тулярина) по показателю «Подлинность».Материалы и методы: испытание показателя качества «Подлинность» проводили на образцах фармакопейного стандартного образца вакцины чумной живой и трех коммерческих серий вакцины; аллергена туляремийного жидкого (Тулярин) двух серий. Исследование показателя качества «Подлинность» препаратов ИХ методом проводили с помощью следующих наборов реагентов: ИХ тест-система для экспресс-выявления и идентификации микробных клеток Yersinia pestis «ИХ тест-система Y. pestis» и ИХ тест-система для экспресс-выявления и идентификации Francisella tularensis «ИХ тест-система F. tularensis» производства ФБУН «Государственный научный центр прикладной микробиологии и биотехнологии».Результаты: показано, что ИХ метод является эффективным экспресс-методом для видоспецифического подтверждения наличия Y. pestis в вакцине чумной живой и F. tularensis в аллергене туляремийном жидком (Тулярин). Установлена рекомендуемая концентрация вакцины чумной живой для проведения испытания по показателю «Подлинность» ИХ методом — 109 м.к./мл. Испытание аллергена туляремийного жидкого (Тулярина) по показателю «Подлинность» ИХ методом рекомендовано проводить с использованием цельного препарата.Выводы: полученные результаты могут служить основанием для внесения ИХ метода с использованием указанных наборов реагентов в нормативную документацию на вакцину чумную живую и на аллерген туляремийный жидкий (Тулярин) в качестве альтернативного метода определения показателя «Подлинность»

    Hydrocarbons in the Suspended Matter and the Bottom Sediments in Different Regions of the Black Sea Russian Sector

    Get PDF
    Clément Pierre. Description d'un nouvel Aphodius [Col. Scarabaeidae] du Maroc. In: Bulletin de la Société entomologique de France, volume 33 (6),1928. pp. 100-101

    Трансформация углеводородов в зоне река – море в Арктике

    Get PDF
    Hydrocarbons (aliphatic and aromatic polyciclic) in water and bottom sediments were investigated on geochemical barrier river (the Northern Dvina, Ob, Yenisei and Lena) to the sea. It is established that there is a sharp decrease in concentration and deposition of anthropogenic hydrocarbons as well as particulates, and other organic compounds, mixing of river water with the sea. Relatively clean water flows to pelagic marine areas. Despite the low Arctic temperature the transformation of anthropogenic hydrocarbons is fast. Therefore, natural compounds predominant in the water and sediments.Проведено изучение углеводородов (алифатических и полициклических ароматических) в воде и донных осадках на геохимическом барьере река (Северная Двина, Обь, Енисей и Лена) – море. Установлено, что при смешении речных вод с морскими происходит резкое снижение концентраций и выпадение антропогенных углеводородов, а также взвеси и других органических соединений. В пелагические морские районы поступают сравнительно чистые воды. Несмотря на низкие арктические температуры, трансформация антропогенных углеводородов происходит настолько быстро, что в основном в воде и донных осадках доминируют природные соединения

    Мониторинг показателей качества вакцин для профилактики туберкулеза методом контрольных карт Шухарта

    Get PDF
    Scientific relevance. The quality of medicinal products, particularly vaccines, is contingent on the stability of the manufacturing process at all stages, which can be evaluated using Shewhart charts for data obtained by monitoring the quality attributes of interest.Aim. This study evaluated the stability of the quality and manufacturing processes of the BCG and BCG-M tuberculosis vaccines using Shewhart charts.Materials and methods. This study focused on samples of the BCG tuberculosis vaccine and the BCG-M tuberculosis vaccine, a less reactogenic alternative for primary immunisation. Both vaccines were released to the market in 2019–2022. The quality of samples was assessed for stability based on their potency and total bacterial count, which are the key parameters for immunogenicity evaluation. These quality parameters were compared using test results submitted by the manufacturer and obtained at the testing centre. The authors plotted individuals charts (X-charts) and moving range charts (R-charts) in accordance with national standards GOST R 50779.42-99 and GOST R ISO 7870-2-2015.Results. The quality of the BCG and BCG-M vaccines remained stable during the entire follow-up period (2019–2022). For some periods, the retrospective analysis of R- and X-charts revealed characteristic trends meeting special cause criteria. The Pearson correlation coefficient (r) between the data submitted by the manufacturer and the data obtained at the testing centre ranged from 0.2 to 0.8.Conclusions. The Shewhart charts demonstrated that the quality parameters of the BCG and BCG-M tuberculosis vaccines tested in 2019–2022 were stable. These vaccines had stable manufacturing processes, as shown by the R- and X-charts. However, the warning signs indicated that additional measures should be taken to standardise the manufacturing processes. The findings suggest that Shewhart charts may be recommended for monitoring the production and quality of tuberculosis vaccines.Актуальность. Производство качественных лекарственных препаратов, в том числе вакцин, возможно только в условиях сохранения стабильности всех стадий технологического процесса производства. Подходом для оценки стабильности процесса производства является использование контрольных карт Шухарта, построенных по данным анализируемых показателей качества.Цель. Оценка стабильности качества туберкулезных вакцин БЦЖ и БЦЖ-М и стабильности процесса их производства с помощью контрольных карт Шухарта.Материалы и методы. Образцы вакцины туберкулезной (БЦЖ) и вакцины туберкулезной для щадящей первичной иммунизации (БЦЖ-М) серий, выпущенных в гражданский оборот в 2019–2022 гг. Стабильность качества вакцин оценивали по показателям качества «Специфическая активность» и «Общее содержание бактерий», которые являются ключевыми при оценке иммуногенности. Сравнительную оценку показателей качества вакцин проводили согласно результатам анализа, предоставленным предприятием-производителем, а также результатам, полученным при контроле качества в испытательном центре. Проводили построение контрольных карт Шухарта индивидуальных значений (Х-карта) и карт скользящих размахов (R-карта) в соответствии с ГОСТ Р 50779.42-99 и ГОСТ Р ИСО 7870-2-2015.Результаты. Показано, что качество вакцин БЦЖ и БЦЖ-М оставалось стабильным в течение всего периода наблюдения (2019–2022 гг.). Ретроспективный анализ R- и X-карт выявил наличие характерных трендов, присущих критериям для особых причин в отдельные временные промежутки исследования. Значение коэффициента корреляции Пирсона (r) между данными производителя и данными, полученными при контроле качества в испытательном центре, составило от 0,2 до 0,8.Выводы. С помощью контрольных карт Шухарта подтверждена стабильность качества туберкулезных вакцин БЦЖ и БЦЖ-М, выпущенных в 2019–2022 гг. Проведенный анализ R- и X-карт свидетельствует о стабильности процесса производства вакцин, однако наличие предупреждающих сигналов указывает на необходимость проведения дополнительных мероприятий, направленных на стандартизацию технологического процесса. Полученные результаты могут служить основанием для рекомендации применения карт Шухарта при производстве и контроле качества туберкулезных вакцин
    corecore