101 research outputs found

    Effect of a thin AlO_x layer on transition-edge sensor properties

    Full text link
    We have studied the physics of transition-edge sensor (TES) devices with an insulating AlOx layer on top of the device to allow implementation of more complex detector geometries. By comparing devices with and without the insulating film, we have observed significant additional noise apparently caused by the insulator layer. In addition, AlOx was found to be a relatively good thermal conductor. This adds an unforeseen internal thermal feature to the system.Comment: 6 pages, 5 figures, Low Temperature Detectors 14 conferenc

    IXO/XMS Detector Trade-Off Study

    Get PDF
    This document presents the outcome of the detector trade-off for the XMS instrument on IXO. This trade-off is part of the Cryogenic instrument Phase-A study as proposed to ESA in the Declaration of Interest SRONXMS-PL-2009-003 dated June 6, 2009. The detector consists of two components: a core array for the highest spectral resolution and an outer array to increase the field of view substantially with modest increase in the number of read-out channels. Degraded resolution of the outer array in comparison with the core array is accepted in order to make this scheme possible. The two detector components may be a single unit or separate units. These arrays comprise pixels and the components that allow them to be arrayed. Each pixel comprises a thermometer, an absorber, and the thermal links between them and to the rest of the array. These links may be interfaces or distinct components. The array infrastructure comprises the mechanical structure of the array, the arrangement of the leads, and features added to improve the integrated thermal properties of the array in the focal-plane assembly

    Fluctuation superconductivity limited noise in a transition-edge sensor

    Get PDF
    In order to investigate the origin of the until now unaccounted excess noise and to minimize the uncontrollable phenomena at the transition in X-ray microcalorimeters we have developed superconducting transition-edge sensors into an edgeless geometry, the so-called Corbino disk (CorTES), with superconducting contacts in the centre and at the outer perimeter. The measured rms current noise and its spectral density can be modeled as resistance noise resulting from fluctuations near the equilibrium superconductor-normal metal boundaryComment: 9 pages, 4 figures.; Corrections to text and equations; replaced the affected figures. Added reference [12

    Ultrasensitive TES Bolometers for Space Based FIR Astronomy

    Get PDF
    We present results from the development of a background limited transition edge sensor (TES) bolometer for the wavelength band 30–60 μm. The bolometer consists of a Ti/Au superconducting thermometer and a Ta radiation absorber deposited on a 200μm×300μm200μm×300μm membrane of SixNySixNy suspended on long, narrow legs. This device is voltage biased and the current through the device is measured by a SQUID amplifier. The thermometer has transition temperature Tc = 108 mKTc = 108 mK and the device is operated from a 70 mK base plate. FIR radiation is coupled into a multimodc horn with entrance aperture of 450 μm, length 4.5 mm and exit aperture of 45 μm, which feeds a metal integrating cavity containing the detector. The radiation band is defined by a pair of lowpass and highpass mesh filters in front of the horn. Here we present measurements of optical noise equivalent power (NEP), optical efficiency, dynamic range and time constant. The results show that measured TES detectors are close to meeting the requirement of the “Band 3” of SAFARI FTS imaging instrument [1] on the SPICA mission [2]

    Study of the Dependency on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter

    Get PDF
    At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in an AC bias configuration. For x-ray photons at 6 keV the pixel shows an x-ray energy resolution Delta E(sub FWHM) = 3.7 eV, which is about a factor 2 worse than the energy resolution observed in an identical DC-biased pixel. In order to better understand the reasons for this discrepancy we characterized the detector as a function of temperature, bias working point and applied perpendicular magnetic field. A strong periodic dependency of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recently observed weak-link behaviour of a TES microcalorimeter

    Principles of the Field Theory of High Temperature Superconductivity in Underdoped Copper-Oxides

    Full text link
    Here I extend my last work about the origin of the pseudo-gaps in underdoped cuprates (arXiv: cond-mat. 1011.3206), to include the mechanism of superconductivity. This is done by adapting the formalism of the double correlations in systems with nested Fermi surfaces to the semi one dimensional system of strings of holes. It is proposed that magnetic interaction is crucial for the establishment of the pseudogap and the high temperature superconductivity. It is shown that superconductivity disturbs the completeness of the strings of holes, and creates fluctuations in their shapes. This, in turn, reduces the magnetic interaction and the pseudogap order.Comment: This paper has been withdrawn by the author. 27 page

    EURECA: European-Japanese microcalorimeter array

    Get PDF
    The EURECA project aims to demonstrate technological readiness of a micro-calorimeter array for application in future X-ray astronomy missions, like Constellation-X, EDGE, and XEUS. The prototype instrument consists of a 5 Ă— 5 pixel array of TES-based micro-calorimeters read out by two SQUID-amplifier channels using frequency-domain-multiplexing (FDM) with digital base-band feedback. The detector array is cooled by a cryogen-free cryostat consisting of a pulse tube cooler and a two stage ADR. Initial tests of the system at the PTB beam line of the BESSY synchrotron showed stable performance and an X-ray energy resolution of 1.5 eV at 250 eV for read-out of one TES-pixel only. Next step is deployment of FDM to read-out the full array. Full performance demonstration is expected end 2008.This work was financially supported by the Dutch Organization for Scientific Research (NWO).Peer Reviewe

    Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

    Get PDF
    In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field
    • …