47 research outputs found

    Dandy—Walker malformation associated with syringomyelia

    No full text

    Mechanisms underlying the formation and enlargement of noncommunicating syringomyelia: experimental studies

    No full text
    The pathogenesis of noncommunicating syringomyelia is unknown, and none of the existing theories adequately explains the production of cysts that occur in association with conditions other than Chiari malformation. The authors' hypothesis is that an arterial pulsation-driven perivascular flow of cerebrospinal fluid (CSF) is responsible for syrinx formation and enlargement. They investigated normal CSF flow patterns in 20 rats and five sheep by using the tracer horseradish peroxidase; the effect of reducing arterial pulse pressure was examined in four sheep by partially ligating the brachiocephalic trunk; CSF flow was examined in 78 rats with the intraparenchymal kaolin model of noncommunicating syringomyelia; and extracanalicular cysts were examined using the excitotoxic model in 38 rats. In the normal animals there was a rapid flow of CSF from the spinal subarachnoid space into the spinal cord perivascular spaces and then into the central canal. This flow ceased when arterial pulsations were diminished. In animals with noncommunicating syringomyelia, there was rapid CSF flow into isolated and enlarged segments of central canal, even when these cysts were causing pressure damage to the surrounding spinal cord. Exitotoxic injury of the spinal cord caused the formation of extracanalicular cysts, and larger cysts were produced when this injury was combined with arachnoiditis, which impaired subarachnoid CSF flow. The results of these experiments support the hypothesis that arterial pulsation-driven perivascular fluid flow is responsible for syrinx formation and enlargement

    A novel Variable Refrigerant Flow (VRF) heat recovery system model: Development and validation

    No full text
    As one of the latest emerging HVAC technologies, the Variable Refrigerant Flow (VRF) system with heat recovery (HR) configurations has obtained extensive attention from both the academia and industry. Compared with the conventional VRF systems with heat pump (HP) configurations, VRF-HR is capable of recovering heat from cooling zones to heating zones and providing simultaneous cooling and heating operations. This can further lead to substantial energy saving potential and more flexible zonal control. In this paper, a novel model is developed to simulate the energy performance of VRF-HR systems. It adheres to a more physics-based development with the ability to simulate the refrigerant loop performance and consider the dynamics of more operational parameters, which is essential for representing more advanced control logics. Another key feature of the model is the introduction of component-level curves for indoor units and outdoor units instead of overall performance curves for the entire system, and thus it requires much fewer user-specified performance curves as model inputs. The validation study shows good agreements between the simulated energy use from the new VRF-HR model and the laboratory measurement data across all operational modes at sub-hourly time steps. The model has been adopted in the official release of the EnergyPlus simulation program since Version 8.6, which enables more accurate and robust assessments of VRF-HR systems to support their applications in energy retrofit of existing buildings or design of zero-net-energy buildings

    Classification of syringomyelia

    No full text
    corecore