3,718 research outputs found

    Development of colon cancer after liver transplantation for primary sclerosing cholangitis associated with ulcerative colitis

    Get PDF
    Between February 26, 1981, and July 30, 1987, 36 patients underwent orthotopic liver transplantation for primary sclerosing cholangitis associated with ulcerative colitis. Three of the 36 recipients died within 3 mo because of graft nonfunction or surgical complications. The other 33 (92%) lived for at least 1 yr. Two of the 33 died after 12 and 14 mo, respectively, of recurrent cholangiocarcinoma that was not diagnosed before transplantation. Four other patients died of recurrent liver failure (three cases) or immunoblastic sarcoma (one case) after 14, 21, 36 and 44 mo. Twenty‐seven (75%) of the patients are still alive 23 to 81 mo after transplantation. Two patients have been diagnosed as having colorectal cancer 11 and 21 mo respectively, after transplantation, for an overall incidence of 5.6% (2 of 36) and a corrected incidence of 6.5% (2 of 31) if the three early deaths and two later deaths caused by cholangiocarcinomas are excluded. It is not known whether colorectal malignancies were present but undetected at the time of transplantation or whether they developed afterward. It is clear that patients who undergo liver transplantation for primary sclerosing cholangitis associated with ulcerative colitis should have careful follow‐up of the colon, including colonoscopy and multiple biopsies of the colorectal mucosa. Whether proctocolectomy should be considered prophylactically after liver transplantation is an unresolved issue.(HEPATOLOGY 1990;11:477–480.) Copyright © 1990 American Association for the Study of Liver Disease

    Correlation of high energy muons with primary composition in extensive air shower

    Get PDF
    An experimental investigation of high energy muons above 200 GeV in extensive air showers has been made for studying high energy interaction and primary composition of cosmic rays of energies in the range 10 to the 14th power approx. 10 to the 15th power eV. The muon energies are estimated from the burst sizes initiated by the muons in the rock, which are measured by four layers of proportional counters, each of area 5 x 2.6 sq m, placed at 30 m.w.e. deep, Funasaka tunnel vertically below the air shower array. These results are compared with Monte Carlo simulations based on the scaling model and the fireball model for two primary compositions, all proton and mixed

    Proportional drift tubes for large area muon detectors

    Get PDF
    A proportional drift chamber which consists of eight rectangular drift tubes with cross section of 10 cm x 5 cm, a sense wire of 100 micron phi gold-plated tungsten wire and the length of 6 m, was tested using cosmic ray muons. Spatial resolution (rms) is between 0.5 and 1 mm over drift space of 50 mm, depending on incident angle and distance from sense wire

    Cost-Effectiveness of Total Hip and Knee Replacements for the Australian Population with Osteoarthritis: Discrete-Event Simulation Model

    Get PDF
    Background: Osteoarthritis constitutes a major musculoskeletal burden for the aged Australians. Hip and knee replacement surgeries are effective interventions once all conservative therapies to manage the symptoms have been exhausted. This study aims to evaluate the cost-effectiveness of hip and knee replacements in Australia. To our best knowledge, the study is the first attempt to account for the dual nature of hip and knee osteoarthritis in modelling the severities of right and left joints separately
    corecore