401 research outputs found
Turbulence and wind speed proïŹles for simulating the TMT AO performances
The site testing campaign of the Thirty Meter Telescope gathered an extensive amount of turbulence profiles. This data is modeled to describe the statistical characteristics of each site and act as "standard atmospheres" for use in AO simulations
Sky coverage and tip/tilt error analysis for TMT
A Monte Carlo sky coverage model for laser guide star adaptive optics systems is presented. This model provides fast Monte Carlo simulations of the tip/tilt (TT) wavefront error calculated with minimum variance estimators over natural guide star constellations generated from star models. With this simulation code we are able to generate a TT error budget for the Thirty Metre Telescope (TMT) facility Narrow Field Infra-Red Adaptive Optics System (NFIRAOS), and perform several design trade studies. With the current NFIRAOS design, the median TT error at the galactic pole with median seeing is calculated to be 65 nm or 1.8 mas
Deep Near-Infrared Imaging of a Field in the Outer Disk of M82 with the ALTAIR Adaptive Optics System on Gemini North
Deep H and K' images, recorded with the ALTAIR adaptive optics system and
NIRI imager on Gemini North, are used to probe the red stellar content in a
field with a projected distance of 1 kpc above the disk plane of the starburst
galaxy M82. The data have an angular resolution of 0.08 arcsec FWHM, and
individual AGB and RGB stars are resolved. The AGB extends to at least 1.7 mag
in K above the RGB-tip, which occurs at K = 21.7. The relative numbers of
bright AGB stars and RGB stars are consistent with stellar evolution models,
and one of the brightest AGB stars has an H-K color and K brightness that is
consistent with it being a C star. The brightnesses of the AGB stars suggest
that they formed during intermediate epochs, possibily after the last major
interaction with M81. Therefore, star formation in M82 during intermediate
epochs may not have been restricted to the plane of the disk.Comment: 16 pages of text plus 7 postscript figures; to appear in the PAS
The Infrared Imaging Spectrograph (IRIS) for TMT: multi-tiered wavefront measurements and novel mechanical design
The InfraRed Imaging Spectrograph (IRIS) will be the first light adaptive optics instrument on the Thirty Meter Telescope (TMT). IRIS is being built by a collaboration between Caltech, the University of California, NAOJ and NRC Herzberg. In this paper we present novel aspects of the Support Structure, Rotator and On-Instrument Wavefront Sensor systems being developed at NRC Herzberg. IRIS is suspended from the bottom port of the Narrow Field Infrared Adaptive Optics System (NFIRAOS), and provides its own image de-rotation to compensate for sidereal rotation of the focal plane. This arrangement is a challenge because NFIRAOS is designed to host two other science instruments, which imposes strict mass requirements on IRIS. As the mechanical design of all elements has progressed, we have been tasked with keeping the instrument mass under seven tonnes. This requirement has resulted in a mass reduction of 30 percent for the support structure and rotator compared to the most recent IRIS designs. To accomplish this goal, while still being able to withstand earthquakes, we developed a new design with composite materials. As IRIS is a client instrument of NFIRAOS, it benefits from NFIRAOSâs superior AO correction. IRIS plays an important role in providing this correction by sensing low-order aberrations with three On-Instrument Wavefront Sensors (OIWFS). The OIWFS consists of three independently positioned natural guide star wavefront sensor probe arms that patrol a 2-arcminute field of view. We expect tip-tilt measurements from faint stars within the IRIS imager focal plane will further stabilize the delivered image quality. We describe how the use of On-Detector Guide Windows (ODGWs) in the IRIS imaging detector can be incorporated into the AO correction. In this paper, we present our strategies for acquiring and tracking sources with this complex AO system, and for mitigating and measuring the various potential sources of image blur and misalignment due to properties of the mechanical structure and interfaces
Giving Miss Marple a makeover : graduate recruitment, systems failure and the Scottish voluntary sector
The voluntary sector in Scotland, as across the globe, is becoming increasingly business like. Resultantly, there is an increasing demand for graduates to work in business and support functions. In Scotland, however, despite an oversupply of graduates in the labor market, the voluntary sector reports skills shortages for graduate-level positions; a leadership deficit was also reported in countries such as the United States. Through exploratory, mainly qualitative, case study and stakeholder research, this article proposes that one reason for this mismatch between the supply of and demand for graduates is a systems failure within the sector. Many graduates and university students remain unaware of potentially suitable paid job opportunities, in part because of the sector's voluntary label. To rectify this systems failure, thought needs to be given to the sector's nomenclature and the manner in which voluntary sector organizations attract graduate recruits, for example, through levering value congruence in potential recruits
NFIRAOS: TMT facility adaptive optics with conventional DMs
Although many of the instruments planned for the TMT (Thirty Meter Telescope) have their own closely-coupled adaptive optics systems, TMT will also have a facility Adaptive Optics (AO) system feeding three instruments on the Nasmyth platform. For this Narrow-Field Infrared Adaptive Optics System, NFIRAOS (pronounced nefarious), the TMT project considered two architectures. One, described in this paper, employs conventional deformable mirrors with large diameters of about 300 mm and this is the reference design adopted by the TMT project. An alternative design based on MEMS was also studied, and is being presented separately in this conference. The requirements for NFIRAOS include 0.8-5 microns wavelength range, 30 arcsecond diameter output field of view (FOV), excellent sky coverage, and diffraction- limited atmospheric turbulence compensation (specified at 133 nm RMS including residual telescope and science instrument errors.) The reference design for NFIRAOS includes multiple sodium laser guide stars over a 70 arcsecond FOV, and an infrared tip/tilt/focus/astigmatism natural guide star sensor within instruments. Larger telescopes require greater deformable mirror (DM) stroke. Although initially NFIRAOS will correct a 10 arcsecond science field, it uses two deformable mirrors in series, partly to provide sufficient stroke for atmospheric correction over the 30 m telescope aperture, but mainly to partially correct a 2 arcminute diameter "technical" field to sharpen near-IR natural guide stars and improve sky coverage. The planned upgrade to full performance includes replacing the groundconjugated DM with a higher actuator density, and using a deformable telescope secondary mirror as a "woofer." NFIRAOS incorporates an instrument rotator and selection of three live instruments: a near-Infrared integral field Imaging spectrograph, a near-infrared echelle spectrograph, and after upgrading NFIRAOS to full multi-conjugation, a wide field (30 arcsecond) infrared camera
British Lung Foundation/United Kingdom primary immunodeficiency network consensus statement on the definition, diagnosis, and management of granulomatous-lymphocytic interstitial lung disease in common variable immunodeficiency disorders
A proportion of people living with common variable immunodeficiency disorders develop granulomatous-lymphocytic interstitial lung disease (GLILD). We aimed to develop a consensus statement on the definition, diagnosis, and management of GLILD. All UK specialist centers were contacted and relevant physicians were invited to take part in a 3-round online Delphi process. Responses were graded as Strongly Agree, Tend to Agree, Neither Agree nor Disagree, Tend to Disagree, and Strongly Disagree, scored +1, +0.5, 0, â0.5, and â1, respectively. Agreement was defined as greater than or equal to 80% consensus. Scores are reported as mean ± SD. There was 100% agreement (score, 0.92 ± 0.19) for the following definition: âGLILD is a distinct clinico-radio-pathological ILD occurring in patients with [common variable immunodeficiency disorders], associated with a lymphocytic infiltrate and/or granuloma in the lung, and in whom other conditions have been considered and where possible excluded.â There was consensus that the workup of suspected GLILD requires chest computed tomography (CT) (0.98 ± 0.01), lung function tests (eg, gas transfer, 0.94 ± 0.17), bronchoscopy to exclude infection (0.63 ± 0.50), and lung biopsy (0.58 ± 0.40). There was no consensus on whether expectant management following optimization of immunoglobulin therapy was acceptable: 67% agreed, 25% disagreed, score 0.38 ± 0.59; 90% agreed that when treatment was required, first-line treatment should be with corticosteroids alone (score, 0.55 ± 0.51)
Commercial weight loss diets meet nutrient requirements in free living adults over 8 weeks: A randomised controlled weight loss trial
Objective: To investigate the effect of commercial weight loss programmes on macronutrient composition and micronutrient adequacy over a 2 month period
The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview
We present an overview of the design of IRIS, an infrared (0.84 - 2.4 micron)
integral field spectrograph and imaging camera for the Thirty Meter Telescope
(TMT). With extremely low wavefront error (<30 nm) and on-board wavefront
sensors, IRIS will take advantage of the high angular resolution of the narrow
field infrared adaptive optics system (NFIRAOS) to dissect the sky at the
diffraction limit of the 30-meter aperture. With a primary spectral resolution
of 4000 and spatial sampling starting at 4 milliarcseconds, the instrument will
create an unparalleled ability to explore high redshift galaxies, the Galactic
center, star forming regions and virtually any astrophysical object. This paper
summarizes the entire design and basic capabilities. Among the design
innovations is the combination of lenslet and slicer integral field units, new
4Kx4k detectors, extremely precise atmospheric dispersion correction, infrared
wavefront sensors, and a very large vacuum cryogenic system.Comment: Proceedings of the SPIE, 9147-76 (2014
- âŠ