2,706 research outputs found
Studies in predictor display technique Final report
Predictor display technique for manual altitude control, and automatic pitch axis performanc
Collaborative research and the co-production of knowledge for practice: an illustrative case study.
This is the final version of the article. Available from BioMed Central via the DOI in this record.BACKGROUND: In 2008, the National Institute for Health Research (NIHR) began funding a major 5-year pilot research programme of translational research in England, establishing nine 'Collaborations for Leadership in Applied Health Research and Care' (CLAHRCs). A number of evaluations were carried out to examine whether or not the various collaborations worked as intended and why. In this paper, we examine what the theory of co-production adds to understanding of processes of knowledge creation and translation we observed in one of the CLAHRCs. METHODS: A case study of a successful knowledge translation project was identified from our wider realist evaluation of the mechanisms of closer collaboration at play in the CLAHRC. In the project, a computer simulation model of an emergency pathway for acute ischaemic stroke was built to explore if and how the time between the onset and treatment of the condition could be minimised by redesigning the pathway. The aim of the case study was to improve our understanding of the nature and workings of the mechanisms of closer collaboration that were associated with the more successful projects by examining the relevance of the theory of co-production. Qualitative methods of analysis were used to explore the fit between the mechanisms of closer collaboration we observed in the realist evaluation and the principles of co-production we identified from the literature. RESULTS: We found a close fit between the nine mechanisms of closer collaboration at work in the project and the principles of co-production (active agents; equality of partners; reciprocity and mutuality; transformative; and facilitated). The successful style of collaborative working exemplified by the project was consistent with a strong form of co-production. CONCLUSIONS: In our view, the theory of co-production provides useful insights into what it is about the qualities of collaborative working that inspire the requisite mechanisms for generating knowledge that is translated into practice. The theory provides a potentially useful basis for future knowledge translation programmes and projects in applied health research in a range of contexts.We would like to thank the participants for taking part in this research and
giving their time so generously and the reviewers for their helpful
comments on an earlier version of the paper.
This research was supported by the National Institute for Health Research
(NIHR) Collaboration for Leadership in Applied Health Research and Care
South-West Peninsula. The views expressed are those of the authors and not
necessarily those of the NHS, the NIHR or the Department of Health
Validation of electron density profiles derived from oblique ionograms over the United Kingdom
Inversion algorithms are available to derive the vertical electron density profile at the midpoint of an oblique sounder path. The techniques open up the possibility of monitoring the ionosphere at otherwise inaccessible locations, such as over sea or inhospitable terrain. A new method of monitoring the ionosphere based on radio tomography can be used to create two-dimensional images of electron density. The results in this paper compare midpoint profiles derived from oblique ionograms with corresponding profiles obtained from tomographic images of electron density and from a vertical ionospheric sounder. The comparisons illustrate the oblique sounder inversion technique and its inherent limitations. The results provide useful information on the complementary nature of the separate ionospheric measurement techniques and have implications for the use of these measurements as inputs to real-time ionospheric models
Reply to Comment by J. Zhang and N. Makris on “Estimates of the Ground Accelerations at Point Reyes Station during the 1906 San Francisco Earthquake” by A. Anooshehpoor, T. H. Heaton, B. Shi, and J. N. Brune
Contrary to the comments by Zhang and Makris (hereafter, ZM), our equations of motion governing the rocking response of a rectangular block subjected to a full-sine acceleration pulse are correct. Therefore, the first part of ZM's discussion, which is based primarily upon the assumption that the equations of motion in our article were incorrect, is inappropriate. In the second part of the discussion, ZM present new results for mode 2, toppling without impact. We did not consider this mode because it was not relevant to the Point Reyes train, which by eyewitness accounts, had overturned after experiencing one impact. However, as explained in this reply, toppling with no impact is never the minimum condition for overturning, and would in general involve very large horizontal accelerations, especially at frequencies where mode 2 is the only overturning mode
Application of radio tomographic imaging to HF oblique incidence ray tracing
Radio tomography is a technique for generating images of the spatial structure of ionospheric electron density over a wide area. This paper assesses the potential use of radio tomography in HF oblique propagation and ray tracing applications. Synthetic ionograms produced by ray tracing through tomographic images and ionospheric models have been compared with experimental oblique ionograms from six paths lying close to the image plane in the United Kingdom. In particular, study has been made of the effects of various types of input information used to constrain the vertical electron density structure in the tomographic reconstructions. It was found that use of a fine height resolution (5 km) and incorporation of information from one vertical ionosonde in the reconstruction process makes significant improvements to the overall reliability of the tomographic image. As expected, E layer propagation is better defined using a climatological model than by tomography. However, in comparison with three ionospheric models, use of tomographic images can significantly reduce the RMS error in the determination of the F2 layer maximum usable frequency
- …