533 research outputs found

    Self-terminating re-entrant cardiac arrhythmias: quantitative characterization

    Get PDF
    Atrial and ventricular tachyarrhythmia are often sustained by re-entrant propagation, and explained by deterministic models. A quantitative, stochastic description of self-termination provides an alternative to the current paradigm for re-entrant tachyarrhythmia - that of triggers and a substrate, modelled by parametrically heterogeneous deterministic partial differential equations. Atrial and ventricular data was from recordings obtained during routine clinical monitoring and treatment, either noninvasively or invasively. Atrial and ventricular tachycardia are characterised by their initiation times and durations, re-presented as instantaneous rates, whose means estimate transition probabilities/s for onset and termination. These estimated probabilities range from 10(-9) to 10(-1)/s

    Highly sensitive contact pressure measurements using FBG patch in endotracheal tube cuff

    Get PDF
    A method for measuring the contact pressure between an endotracheal tube cuff and the trachea was designed and developed by using a fibre Bragg grating (FBG) based optical fibre sensor. The FBG sensor is encased in an epoxy based UV-cured cuboid patch and transduces the transversely loaded pressure into an axial strain that induces wavelength shift of the Bragg reflection. The polymer patch was created by using a PTFE based mould and increases tensile strength and sensitivity of the bare fibre FBG to pressure to 2.10×10-2 nm/kPa. The characteristics of the FBG patch allow for continuous measurement of contact pressure. The measurement of contact pressure was demonstrated by the use of a 3D printed model of a human trachea. The influence of temperature on the measurements is reduced significantly by the use of a second FBG sensor patch that is not in contact with the trachea. Intracuff pressure measurements performed using a commercial manometer agreed well with the FBG contact pressure measurements. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only

    Simultaneous temperature and humidity measurements in a mechanical ventilator using an optical fibre sensor

    Get PDF
    An optical fibre sensor for simultaneous temperature and humidity measurements consisting of one fibre Bragg grating (FBG) to measure temperature and a mesoporous film of bilayers of Poly(allylamine hydrochloride)(PAH) and silica (SiO2) nanoparticles deposited onto the tip of the same fibre to measure humidity is reported. The hygroscopic film was created using the layer-by-layer (LbL) method and the optical reflection spectra were measured up to a maximum of 23 bilayers. The temperature sensitivity of the FBG was 10 pm/°C while the sensitivity to humidity was (-1.4x10-12 W / %RH) using 23 bilayers. The developed sensor was tested in the mechanical ventilator and temperature and humidity of the delivered artificial air was simultaneously measured. Once calibrated, the optical fibre sensor has the potential to control the absolute humidity as an essential part of critical respiratory care. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only

    Motion limitations of non-contact photoplethysmography due to the optical and topological properties of skin

    Get PDF
    Non-contact photoplethysmography (PPG) provides multiple benefits over in-contact methods, but is not as tolerant to motion due to the lack of mechanical coupling between the subject and sensor. One limitation of non-contact photoplethysmography is discussed here, specifically looking at the topology and optical variations of the skin and how this impacts upon the ability to extract a photoplethysmogram when a subject moves horizontally across the field of view of the detector (a panning motion). When this occurs it is shown that whilst the general relationships between the speed of traversal, detection area and resultant signal quality can be found, the quality of signal in each individual case is determined by the properties of the area of skin chosen

    Gender moderates the relationship between empathy and aggressiveness in sport: The mediating role of anger

    Get PDF
    This research investigated whether gender moderates, and anger mediates, the relationship between empathy (i.e., perspective taking and empathic concern) and aggressiveness in sport. In Study 1, perspective taking and empathic concern were negatively associated with aggressiveness, and this effect was stronger in women compared to men. In Study 2, perspective taking was a negative predictor of aggressiveness and antisocial behavior in sport, and anger mediated these relationships in women, but not in men. Our findings suggest that empathy and emotion-based strategies targeted at reducing aggressiveness in sport need to be tailored for males and females

    Interpretation of heart rate variability via detrended fluctuation analysis and alpha-beta filter

    Full text link
    Detrended fluctuation analysis (DFA), suitable for the analysis of nonstationary time series, has confirmed the existence of persistent long-range correlations in healthy heart rate variability data. In this paper, we present the incorporation of the alpha-beta filter to DFA to determine patterns in the power-law behaviour that can be found in these correlations. Well-known simulated scenarios and real data involving normal and pathological circumstances were used to evaluate this process. The results presented here suggest the existence of evolving patterns, not always following a uniform power-law behaviour, that cannot be described by scaling exponents estimated using a linear procedure over two predefined ranges. Instead, the power law is observed to have a continuous variation with segment length. We also show that the study of these patterns, avoiding initial assumptions about the nature of the data, may confer advantages to DFA by revealing more clearly abnormal physiological conditions detected in congestive heart failure patients related to the existence of dominant characteristic scales.Comment: 18 pages, 14 figure

    Forehead reflectance photoplethysmography to monitor heart rate: preliminary results from neonatal patients

    Get PDF
    Around 5%–10% of newborn babies require some form of resuscitation at birth and heart rate (HR) is the best guide of efficacy. We report the development and first trial of a device that continuously monitors neonatal HR, with a view to deployment in the delivery room to guide newborn resuscitation. The device uses forehead reflectance photoplethysmography (PPG) with modulated light and lock-in detection. Forehead fixation has numerous advantages including ease of sensor placement, whilst perfusion at the forehead is better maintained in comparison to the extremities. Green light (525 nm) was used, in preference to the more usual red or infrared wavelengths, to optimize the amplitude of the pulsatile signal. Experimental results are presented showing simultaneous PPG and electrocardiogram (ECG) HRs from babies (n = 77), gestational age 26–42 weeks, on a neonatal intensive care unit. In babies ≄32 weeks gestation, the median reliability was 97.7% at ±10 bpm and the limits of agreement (LOA) between PPG and ECG were +8.39 bpm and −8.39 bpm. In babies <32 weeks gestation, the median reliability was 94.8% at ±10 bpm and the LOA were +11.53 bpm and −12.01 bpm. Clinical evaluation during newborn deliveries is now underway

    U-shape functionalized optical fibre sensors for measurement of anaesthetic propofol

    Get PDF
    Propofol is used widely for intravenous anaesthesia during surgery and sedation in critical care. There is no method currently to assay the concentration of propofol in plasma in real time. The ability to do so would significantly improve patient safety. A novel approach to propofol assay consisting of Beta-Cyclodextrin (ÎČ−CD) assisted propofol-imprinting onto TiO2 films deposited on U-shaped optical fibres was used for the measurement of propofol in aqueous solutions. The sensing mechanism is based on the measurement of the refractive index change induced by the removing and binding of the propofol from and to the ÎČ−CD/propofol complex embedded onto TiO2 films, respectively. Complexation between host (ÎČ−CD) and guest (propofol) was confirmed by nuclear magnetic resonance (NMR) spectroscopy, UV-Vis spectroscopy, and by Attenuated Total Reflectance- Fourier-transform infrared spectroscopy (FTIR). The developed sensors presented Langmuir adsorption in the mM range and the lowest concentration detected was 0.69 ÎŒM= 0.12 ÎŒg/ml. The approach can be replicated for other compounds in other biomedical applications such as vitamins, hormones, or drugs

    An automated quasi-continuous capillary refill timing device

    Get PDF
    Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed CRT is subject to bias from ambient light conditions, a lack of standardisation of both blanching time and manually applied pressure, subjectiveness of return to normal colour, and variability in the manual assessment of time. We present a novel automated system for CRT measurement, incorporating three components: a non-invasive adhesive sensor incorporating a pneumatic actuator, a diffuse multi-wavelength reflectance measurement device, and a temperature sensor; a battery operated datalogger unit containing a self contained pneumatic supply; and PC based data analysis software for the extraction of refill time, patient skin surface temperature, and sensor signal quality. Through standardisation of the test, it is hoped that some of the shortcomings of manual CRT can be overcome. In addition, an automated system will facilitate easier integration of CRT into electronic record keeping and clinical monitoring or scoring systems, as well as reducing demands on clinicians. Summary analysis of volunteer (n = 30) automated CRT datasets are presented, from 15 healthy adults and 15 healthy children (aged from 5 to 15 years), as their arms were cooled from ambient temperature to 5°C. A more detailed analysis of two typical datasets is also presented, demonstrating that the response of automated CRT to cooling matches that of previously published studies
    • 