13,488 research outputs found
Mixing and transient interface condensation of a liquid hydrogen tank
Experiments were conducted to investigate the effect of axial jet-induced mixing on the pressure reduction of a thermally stratified liquid hydrogen tank. The tank was nearly cylindrical, having a volume of about 0.144 cu m with 0.559 m in diameter and 0.711 m long. A mixer/pump unit, which had a jet nozzle outlet of 0.0221 m in diameter was located 0.178 m from the tank bottom and was installed inside the tank to generate the axial jet mixing and tank fluid circulation. The liquid fill and jet flow rate ranged from 42 to 85 percent (by volume) and 0.409 to 2.43 cu m/hr, respectively. Mixing tests began with the tank pressure ranging from 187.5 to 238.5 kPa at which the thermal stratification results in 4.9 to 6.2 K liquid sub cooling. The mixing time and transient vapor condensation rate at the liquid-vapor interface are determined. Two mixing time correlations, based on the thermal equilibrium and pressure equilibrium, are developed. Both mixing time correlations are expressed as functions of system and buoyancy parameters and compared well with other experimental data. The steady state condensation rate correlation of Sonin et al. based on steam-water data is modified and expressed as a function of jet subcooling. The limited liquid hydrogen data of the present study shows that the modified steady state condensation rate correlation may be used to predict the transient condensation rate in a mixing process if the instantaneous values of jet sub cooling and turbulence intensity at the interface are employed
Human-centric light sensing and estimation from RGBD images: the invisible light switch
Lighting design in indoor environments is of primary importance for at least two reasons: 1) people should perceive an adequate light; 2) an effective lighting design means consistent energy saving. We present the Invisible Light Switch (ILS) to address both aspects. ILS dynamically adjusts the room illumination level to save energy while maintaining constant the light level perception of the users. So the energy saving is invisible to them. Our proposed ILS leverages a radiosity model to estimate the light level which is perceived by a person within an indoor environment, taking into account the person position and her/his viewing frustum (head pose). ILS may therefore dim those luminaires, which are not seen by the user, resulting in an effective energy saving, especially in large open offices (where light may otherwise be ON everywhere for a single person). To quantify the system performance, we have collected a new dataset where people wear luxmeter devices while working in office rooms. The luxmeters measure the amount of light (in Lux) reaching the people gaze, which we consider a proxy to their illumination level perception. Our initial results are promising: in a room with 8 LED luminaires, the energy consumption in a day may be reduced from 18585 to 6206 watts with ILS (currently needing 1560 watts for operations). While doing so, the drop in perceived lighting decreases by just 200 lux, a value considered negligible when the original illumination level is above 1200 lux, as is normally the case in offices
ANALISIS FAKTOR KEAMANAN DAN PENANGANAN LERENG PADA RUAS JALAN BLANG KEUJEREN - PEURELAK KABUPATEN GAYO LUWES MENGGUNAKAN SOFTWARE PLAXIS
Towards the Formal Reliability Analysis of Oil and Gas Pipelines
It is customary to assess the reliability of underground oil and gas
pipelines in the presence of excessive loading and corrosion effects to ensure
a leak-free transport of hazardous materials. The main idea behind this
reliability analysis is to model the given pipeline system as a Reliability
Block Diagram (RBD) of segments such that the reliability of an individual
pipeline segment can be represented by a random variable. Traditionally,
computer simulation is used to perform this reliability analysis but it
provides approximate results and requires an enormous amount of CPU time for
attaining reasonable estimates. Due to its approximate nature, simulation is
not very suitable for analyzing safety-critical systems like oil and gas
pipelines, where even minor analysis flaws may result in catastrophic
consequences. As an accurate alternative, we propose to use a
higher-order-logic theorem prover (HOL) for the reliability analysis of
pipelines. As a first step towards this idea, this paper provides a
higher-order-logic formalization of reliability and the series RBD using the
HOL theorem prover. For illustration, we present the formal analysis of a
simple pipeline that can be modeled as a series RBD of segments with
exponentially distributed failure times.Comment: 15 page
Self-pressurization of a flightweight liquid hydrogen storage tank subjected to low heat flux
Results are presented for an experimental investigation of self-pressurization and thermal stratification of a 4.89 cu m liquid hydrogen (LH2) storage tank subjected to low heat flux (0.35, 2.0, and 3.5 W/sq m) under normal gravity conditions. Tests were performed at fill levels of 83 to 84 percent (by volume). The LH2 tank was representative of future spacecraft tankage, having a low mass-to-volume ratio and high performance multilayer thermal insulation. Results show that the pressure rise rate and thermal stratification increase with increasing heat flux. At the lowest heat flux, the pressure rise rate is comparable to the homogenous rate, while at the highest heat flux, the rate is more than three times the homogeneous rate. It was found that initial conditions have a significant impact on the initial pressure rise rate. The quasi-steady pressure rise rates are nearly independent of the initial condition after an initial transient period has passed
A pressure control analysis of cryogenic storage systems
Self-pressurization of cryogenic storage tanks due to heat leak through the thermal protection system is examined along with the performance of various pressure control technologies for application in microgravity environments. Methods of pressure control such as fluid mixing, passive thermodynamic venting, and active thermodynamic venting are analyzed using the homogeneous thermodynamic model. Simplified equations suggested may be used to characterize the performance of various pressure control systems and to design space experiments
Self-pressurization of a flightweight liquid hydrogen tank: Effects of fill level at low wall heat flux
Experimental results are presented for the self pressurization and thermal stratification of a 4.89 cu m liquid hydrogen storage tank subjected to low heat flux (2.0 and 3.5 W/sq m) in normal gravity. The test tank was representative of future spacecraft tankage, having a low mass to volume ratio and high performance multilayer thermal insulation. Tests were performed at fill levels of 29 and 49 pcts. (by volume) and complement previous tests at 83 pct. fill. As the heat flux increases, the pressure rise rate at each fill level exceeds the homogeneous rate by an increasing ratio. Herein, this ratio did not exceed a value of 2. The slowest pressure rise rate was observed for the 49 pct. fill level at both heat fluxes. This result is attributed to the oblate spheroidal tank geometry which introduces the variables of wetted wall area, liquid-vapor interfacial area, and ratio of side wall to bottom heating as a function of fill level or liquid depth. Initial tank thermal conditions were found to affect the initial pressure rise rate. Quasi steady pressure rise rates are independent of starting conditions
TeV Gamma Rays from Geminga and the Origin of the GeV Positron Excess
The Geminga pulsar has long been one of the most intriguing MeV-GeV gamma-ray
point sources. We examine the implications of the recent Milagro detection of
extended, multi-TeV gamma-ray emission from Geminga, finding that this reveals
the existence of an ancient, powerful cosmic-ray accelerator that can plausibly
account for the multi-GeV positron excess that has evaded explanation. We
explore a number of testable predictions for gamma-ray and electron/positron
experiments (up to ~100 TeV) that can confirm the first "direct" detection of a
cosmic-ray source.Comment: 4 pages and 3 figures; Minor revisions, accepted for publication in
Physical Review Letter
Surface electronic structure of a topological Kondo insulator candidate SmB6: insights from high-resolution ARPES
The Kondo insulator SmB6 has long been known to exhibit low temperature (T <
10K) transport anomaly and has recently attracted attention as a new
topological insulator candidate. By combining low-temperature and high
energy-momentum resolution of the laser-based ARPES technique, for the first
time, we probe the surface electronic structure of the anomalous conductivity
regime. We observe that the bulk bands exhibit a Kondo gap of 14 meV and
identify in-gap low-lying states within a 4 meV window of the Fermi level on
the (001)-surface of this material. The low-lying states are found to form
electron-like Fermi surface pockets that enclose the X and the Gamma points of
the surface Brillouin zone. These states disappear as temperature is raised
above 15K in correspondence with the complete disappearance of the 2D
conductivity channels in SmB6. While the topological nature of the in-gap
metallic states cannot be ascertained without spin (spin-texture) measurements
our bulk and surface measurements carried out in the
transport-anomaly-temperature regime (T < 10K) are consistent with the
first-principle predicted Fermi surface behavior of a topological Kondo
insulator phase in this material.Comment: 4 Figures, 6 Page
- …
