8 research outputs found
The Inhalation Characteristics of Patients When They Use Different Dry Powder Inhalers
Background: The characteristics of each inhalation maneuver when patients use dry powder inhalers (DPIs) are important, because they control the quality of the emitted dose.
Methods: We have measured the inhalation profiles of asthmatic children [CHILD; n=16, mean forced expiratory volume in 1 sec (FEV1) 79% predicted], asthmatic adults (ADULT; n=53, mean predicted FEV1 72%), and chronic obstructive pulmonary disease (COPD; n=29, mean predicted FEV1 42%) patients when they inhaled through an Aerolizer, Diskus, Turbuhaler, and Easyhaler using their “real-life” DPI inhalation technique. These are low-, medium-, medium/high-, and high-resistance DPIs, respectively. The inhalation flow against time was recorded to provide the peak inhalation flow (PIF; in L/min), the maximum pressure change (ΔP; in kPa), acceleration rates (ACCEL; in kPa/sec), time to maximum inhalation, the length of each inhalation (in sec), and the inhalation volume (IV; in liters) of each inhalation maneuver.
Results: PIF, ΔP, and ACCEL values were consistent with the order of the inhaler's resistance. For each device, the inhalation characteristics were in the order ADULT>COPD>CHILD for PIF, ΔP, and ACCEL (p4 L and ΔP >4 kPa.
Conclusion: The large variability of these inhalation characteristics and their range highlights that if inhalation profiles were used with compendial in vitro dose emission measurements, then the results would provide useful information about the dose patients inhale during routine use. The inhalation characteristics highlight that adults with asthma have greater inspiratory capacity than patients with COPD, whereas children with asthma have the lowest. The significance of the inhaled volume to empty doses from each device requires investigation
Variability in the organisation and management of hospital care for COPD exacerbations in the UK
SummaryPrevious smaller UK audits have demonstrated wide variation in organisation, resources, and process of care for acute chronic obstructive pulmonary disease (COPD) admissions. Smallest units appeared to do less well.UK acute hospitals supplied information on (1) resources and organisation of care, (2) clinical data on process of care and outcomes for up to 40 consecutive COPD admissions. Comparisons were made against national recommendations.Eight thousand and thirteen admissions involved 7529 patients from 233 units (93% of UK acute Trusts). Twenty-six percent of units had at most one whole-time equivalent respiratory consultant while 12% had at least four. Thirty percent patients were admitted under a respiratory specialist and 48% discharged under their care whilst 28% had no specialist input at all. Variation in care provision was wide across all hospitals but patients in smaller hospitals had less access to specialist respiratory or admission wards, pulmonary rehabilitation programs, speciality triage or an early discharge scheme. Six percent of units did not have access to NIV and 18% to invasive ventilatory support.There remains wide variation in all aspects of acute hospital COPD care in the UK, with smaller hospitals offering fewest services. Those receiving specialist input are more likely to be offered interventions of proven effect. Management guidelines alone are insufficient to address inequalities of care and a clear statement of minimum national standards for resource provision and organisation of COPD care are required. This study provides a unique insight into the current state of care for patients admitted with COPD exacerbations in the UK
Introducing the national COPD resources and outcomes project
<p>Abstract</p> <p>Background</p> <p>We report baseline data on the organisation of COPD care in UK NHS hospitals participating in the National COPD Resources and Outcomes Project (NCROP).</p> <p>Methods</p> <p>We undertook an initial survey of participating hospitals in 2007, looking at organisation and performance indicators in relation to general aspects of care, provision of non-invasive ventilation (NIV), pulmonary rehabilitation, early discharge schemes, and oxygen. We compare, where possible, against the national 2003 audit.</p> <p>Results</p> <p>100 hospitals participated. These were typically larger sized Units. Many aspects of COPD care had improved since 2003. Areas for further improvement include organisation of acute care, staff training, end-of-life care, organisation of oxygen services and continuation of pulmonary rehabilitation.</p> <p>Conclusion</p> <p>Key Points: positive change occurs over time and repeated audit seems to deliver some improvement in services. It is necessary to assess interventions such as the Peer Review used in the NCROP to achieve more comprehensive and rapid change.</p
Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study.
BACKGROUND: Spiromax® is a novel dry-powder inhaler containing formulations of budesonide plus formoterol (BF). The device is intended to provide dose equivalence with enhanced user-friendliness compared to BF Turbuhaler® in asthma and chronic obstructive pulmonary disease (COPD). The present study was performed to compare inhalation parameters with empty versions of the two devices, and to investigate the effects of enhanced training designed to encourage faster inhalation. METHODS: This randomised, open-label, cross-over study included children with asthma (n = 23), adolescents with asthma (n = 27), adults with asthma (n = 50), adults with COPD (n = 50) and healthy adult volunteers (n = 50). Inhalation manoeuvres were recorded with each device after training with the patient information leaflet (PIL) and after enhanced training using an In-Check Dial device. RESULTS: After PIL training, peak inspiratory flow (PIF), maximum change in pressure (∆P) and the inhalation volume (IV) were significantly higher with Spiromax than with the Turbuhaler device (p values were at least <0.05 in all patient groups). After enhanced training, numerically or significantly higher values for PIF, ∆P, IV and acceleration remained with Spiromax versus Turbuhaler, except for ∆P in COPD patients. After PIL training, one adult asthma patient and one COPD patient inhaled <30 L/min through the Spiromax compared to one adult asthma patient and five COPD patients with the Turbuhaler. All patients achieved PIF values of at least 30 L/min after enhanced training. CONCLUSIONS: The two inhalers have similar resistance so inhalation flows and pressure changes would be expected to be similar. The higher flow-related values noted for Spiromax versus Turbuhaler after PIL training suggest that Spiromax might have human factor advantages in real-world use. After enhanced training, the flow-related differences between devices persisted; increased flow rates were achieved with both devices, and all patients achieved the minimal flow required for adequate drug delivery. Enhanced training could be useful, especially in COPD patients
Determination of the Relative Bioavailability of salbutamol to the lungs following inhalation from dry powder inhaler formulations containing drug substance Manufactured by supercritical fluids and micronization
NoPurpose The relative lung bioavailability of salbutamol sulfate particles produced using supercritical fluids (SEDS¿) and delivered by dry powder inhaler (DPI) was compared with the performance of a conventional micronized drug DPI using the same device design (Clickhaler¿, Innovata Biomed).
Materials and Methods Twelve healthy volunteers and 11 mild asthmatic patients completed separate four-way randomised cross-over studies, assessing the relative bioavailability of salbutamol sulfate (urinary excretion method), formulated as SEDS¿ particles (three batches) and micronized particles (Asmasal¿ inhaler, UCB Pharma Ltd). Post-treatment improvements in patient lung function were assessed by measuring FEV1. Physicochemical evaluation of the three SEDS¿ batches revealed inter-batch differences in particle size and shape.
Results There was no significant difference in the relative lung bioavailability of salbutamol and its bronchodilator response between the best performing SEDS¿ formulation and the Asmasal¿ inhaler in volunteers and patients, respectively. SEDS¿ salbutamol sulfate showing wafer like morphology gave greater fine particle dose, relative lung bioavailability and enhanced bronchodilation compared to other SEDS¿ batches containing elongated particles.
Conclusions Active Pharmaceutical Ingredient (API) manufactured using supercritical fluids and delivered by DPI can provide similar lung bioavailability and clinical effect to the conventional micronized commercial product. Product performance is however notably influenced by inter-batch differences in particle characteristics