59 research outputs found

    Long-term in-vitro precision of direct digital X-ray radiogrammetry

    Get PDF
    Digital X-ray radiogrammetry (DXR) calculates peripheral bone mineral density (BMD) from hand radiographs. The short-term precision for direct DXR has been reported to be highly satisfactory. However, long-term precision for this method has not been examined. Thus, the aim of this study was to examine the long-term in-vitro precision for the new direct digital version of DXR. The in-vitro precision for direct DXR was tested with cadaver phantoms on four different X-ray systems at baseline, 3 months, 6 months, and in one machine also at 12 months. At each time point, 31 measurements were performed. The in-vitro longitudinal precision for the four radiographic systems ranged from 0.22 to 0.43% expressed as coefficient of variation (CV%). The smallest detectable difference (SDD) ranged from 0.0034 to 0.0054 g/cm(2). The in vitro long-term precision for direct DXR was comparable to the previous reported short-term in-vitro precision for all tested X-ray systems. These data show that DXR is a stable method for detecting small changes in bone density during 6-12 months of follow-up

    Energy expenditure of rugby players during a 14-day in-season period, measured using doubly labelled water.

    Get PDF
    Criterion data for total energy expenditure (TEE) in elite rugby are lacking, which prediction equations may not reflect accurately. This study quantified TEE of 27 elite male rugby league (RL) and rugby union (RU) players (U16, U20, U24 age groups) during a 14-day in-season period using doubly labelled water (DLW). Measured TEE was also compared to estimated, using prediction equations. Resting metabolic rate (RMR) was measured using indirect calorimetry, and physical activity level (PAL) estimated (TEE:RMR). Differences in measured TEE were unclear by code and age (RL, 4369 ± 979; RU, 4365 ± 1122; U16, 4010 ± 744; U20, 4414 ± 688; U24, 4761 ± 1523 Kcal.day-1). Differences in PAL (overall mean 2.0 ± 0.4) were unclear. Very likely differences were observed in RMR by code (RL, 2366 ± 296; RU, 2123 ± 269 Kcal.day-1). Differences in relative RMR between U20 and U24 were very likely (U16, 27 ± 4; U20, 23 ± 3; U24, 26 ± 5 Kcal.kg-1.day-1). Differences were observed between measured and estimated TEE, using Schofield, Cunningham and Harris-Benedict equations for U16 (187 ± 614, unclear; -489 ± 564, likely and -90 ± 579, unclear Kcal.day-1), U20 (-449 ± 698, likely; -785 ± 650, very likely and -452 ± 684, likely Kcal.day-1) and U24 players (-428 ± 1292; -605 ± 1493 and -461 ± 1314 Kcal.day-1, all unclear). Rugby players have high TEE, which should be acknowledged. Large inter-player variability in TEE was observed demonstrating heterogeneity within groups, thus published equations may not appropriately estimate TEE

    Impact of Segmentation in Quantitative Computed Tomography

    No full text

    A comparison of the thresholding strategies of micro-CT for periodontal bone loss: A pilot study

    No full text
    10.1259/dmfr/66925194Dentomaxillofacial Radiology422-DREA

    Automatic and accurate reconstruction of distal humerus contours through B-Spline fitting based on control polygon deformation

    No full text
    © IMechE 2014. The strong advent of computer-assisted technologies experienced by the modern orthopedic surgery prompts for the expansion of computationally efficient techniques to be built on the broad base of computer-aided engineering tools that are readily available. However, one of the common challenges faced during the current developmental phase continues to remain the lack of reliable frameworks to allow a fast and precise conversion of the anatomical information acquired through computer tomography to a format that is acceptable to computer-aided engineering software. To address this, this study proposes an integrated and automatic framework capable to extract and then postprocess the original imaging data to a common planar and closed B-Spline representation. The core of the developed platform relies on the approximation of the discrete computer tomography data by means of an original two-step B-Spline fitting technique based on successive deformations of the control polygon. In addition to its rapidity and robustness, the developed fitting technique was validated to produce accurate representations that do not deviate by more than 0.2-mm with respect to alternate representations of the bone geometry that were obtained through different - contact-based - data acquisition or data processing methods
    corecore