468 research outputs found
Recommended from our members
Dislocation imaging of an InAlGaAs opto-electronic modulator using IBICC
This paper presents ion beam induced charge collection (IBICC) contrast images showing regions of differing charge collection efficiency within optoelectronic modulator devices. The experiments were carried out at the Sandia nuclear microprobe using 18 MeV carbon and 2 MeV helium ions. Lines of varying densities are observed to run along the different {l_brace}110{r_brace} directions which correlate with misfit dislocations within the 392nm thick strained layer superlattice quantum well of the modulator structure. Independent cross-sectional TEM studies and the electrical properties of the devices under investigation suggest the presence of threading dislocations in the active device region at a density of {approximately} 10{sup 6} cm{sup {minus}2}. However, no clear evidence of threading dislocations was observed in the IBICC images as they are possibly masked by the strong contrast of the misfit dislocations. Charge carrier transport within the modulator is used to explain the observed contrast. The different signal to noise levels and rates of damage of the incident ions are assessed
Experimental Realization of an Optical One-Way Barrier for Neutral Atoms
We demonstrate an asymmetric optical potential barrier for ultracold 87 Rb
atoms using laser light tuned near the D_2 optical transition. Such a one-way
barrier, where atoms impinging on one side are transmitted but reflected from
the other, is a realization of Maxwell's demon and has important implications
for cooling atoms and molecules not amenable to standard laser-cooling
techniques. In our experiment, atoms are confined to a far-detuned dipole trap
consisting of a single focused Gaussian beam, which is divided near the focus
by the barrier. The one-way barrier consists of two focused laser beams
oriented almost normal to the dipole-trap axis. The first beam is tuned to have
a red (blue) detuning from the F=1 -> F' (F=2 -> F') hyperfine transitions, and
thus presents a barrier only for atoms in the F=2 ground state, while letting
F=1 atoms pass. The second beam pumps the atoms to F=2 on the reflecting side
of the barrier, thus producing the asymmetry.Comment: 5 pages, 4 figures; includes changes to address referee comment
Recommended from our members
HRTEM of extended defects in Tl-2212 thin films
Many applications of high temperature superconductors, HTS, require the presence of lattice defects in the material structure to suppress the motion of magnetic vortices and enhance the critical current density, J{sub c}. The microstructure of Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8{minus}{delta}} (Tl-2212) thin films which have extended defects induced by high energy Au and Cu ion irradiation is studied using high resolution transmission electron microscopy, HRTEM, with slow scan digital imaging. In order to optimize the HTS properties and better analyze the consequent microstructural modification, the fluence is varied. At moderate fluences, resulting in {approximately}4% reduction of the superconducting transition, large enhancements of J{sub c} and vortex pinning potential are observed. The density and microstructure of isolated defects and surrounding structure will be discussed and compared to damage profiles calculated using the TRIM code. Correlation will be made between the HRTEM results and the changes in HTS properties
Effect of Exercise Training on Bone Mineral Density in Post-menopausal Women : A Systematic Review and Meta-Analysis of Intervention Studies
Osteoporosis is a major health problem in post-menopausal women (PMW). Exercise training is considered a cost-effective strategy to prevent osteoporosis in middle aged-older people. The purpose of this study is to summarize the effect of exercise on BMD among PMW. A comprehensive search of electronic databases was conducted through PubMed, Scopus, Web of Science, Cochrane, Science Direct, Eric, ProQuest, and Primo. BMD changes (standardized mean differences: SMD) of the lumbar spine (LS) femoral neck (FN) and/or total hip were considered as outcome measures. After subgroup categorization, statistical methods were used to combine data and compare subgroups. Seventy-five studies were included. The pooled number of participants was 5,300 (intervention group:n= 2,901, control group:n= 2,399). The pooled estimate of random effect analysis was SMD = 0.37, 95%-CI: 0.25-0.50, SMD = 0.33, 95%-CI: 0.23-0.43, and SMD = 0.40, 95%-CI: 0.28-0.51 for LS, FN, and total Hip-BMD, respectively. In the present meta-analysis, there was a significant (p<0.001), but rather low effect (SMD = 0.33-0.40) of exercise on BMD at LS and proximal femur. A large variation among the single study findings was observed, with highly effective studies but also studies that trigger significant negative results. These findings can be largely attributed to differences among the exercise protocols of the studies. Findings suggest that the true effect of exercise on BMD is diluted by a considerable amount of studies with inadequate exercise protocols.Peer reviewe
Hamstring stretch reflex:could it be a reproducible objective measure of functional knee stability?"
Background: The anterior cruciate ligament (ACL) plays an important role in anterior knee stability by preventing anterior translation of the tibia on the femur. Rapid translation of the tibia with respect to the femur produces an ACL-hamstring stretch reflex which may provide an object measure of neuromuscular function following ACL injury or reconstruction. The aim of this study was to determine if the ACL-hamstring stretch reflex could be reliably and consistently obtained using the KT-2000 arthrometer. Methods: A KT-2000 arthrometer was used to translate the tibia on the femur while recording the electromyography over the biceps femoris muscle in 20 participants, all with intact ACLs. In addition, a sub-group comprising 4 patients undergoing a knee arthroscopy for meniscal pathology, were tested before and after anaesthetic and with direct traction on the ACL during arthroscopy. The remaining 16 participants underwent testing to elicit the reflex using the KT-2000 only. Results: A total number of 182 trials were performed from which 70 trials elicited stretch reflex (38.5 %). The mean onset latency of the hamstring stretch reflexes was 58.9 ± 17.9 ms. The average pull force was 195 ± 47 N, stretch velocity 48 ± 35 mm/s and rate of force 19.7 ± 6.4 N/s. Conclusions Based on these results, we concluded that the response rate of the anterior cruciate ligament-hamstring reflex is too low for it to be reliably used in a clinical setting, and thus would have limited value in assessing the return of neuromuscular function following ACL injuries
Physical activity to improve cognition in older adults: can physical activity programs enriched with cognitive challenges enhance the effects? A systematic review and meta-analysis
: EPHPP quality rating scores (DOCX 38 kb
- …