198 research outputs found

    3D motion tracking of pulmonary lesions using CT fluoroscopy images for robotically assisted lung biopsy

    Get PDF
    ABSTRACT We are developing a prototype system for robotically assisted lung biopsy. For directing the robot in biopsy needle placement, we propose a non-invasive algorithm to track the 3D position of the target lesion using 2D CT fluoroscopy image sequences. A small region of the CT fluoroscopy image is registered to a corresponding region in a pre-operative CT volume to infer the position of the target lesion with respect to the imaging plane. The registration is implemented in a coarse to fine fashion. The local deformation between the two regions is modeled by an affine transformation. The sum-of-squared-differences (SSD) between the two regions is minimized using the Levenberg-Marquardt method. Multiresolution and multi-start strategies are used to avoid local minima. As a result, multiple candidate transformations between the two regions are obtained, from which the true transformation is selected by similarity voting. The true transformation of each frame of the CT fluoroscopy image is then incorporated into a Kalman filter to predict the lesion's position for the next frame. Tests were completed to evaluate the performance of the algorithm using a respiratory motion simulator and a swine animal study

    First results from the CRESST-III low-mass dark matter program

    Full text link
    The CRESST experiment is a direct dark matter search which aims to measure interactions of potential dark matter particles in an earth-bound detector. With the current stage, CRESST-III, we focus on a low energy threshold for increased sensitivity towards light dark matter particles. In this manuscript we describe the analysis of one detector operated in the first run of CRESST-III (05/2016-02/2018) achieving a nuclear recoil threshold of 30.1eV. This result was obtained with a 23.6g CaWO4_4 crystal operated as a cryogenic scintillating calorimeter in the CRESST setup at the Laboratori Nazionali del Gran Sasso (LNGS). Both the primary phonon/heat signal and the simultaneously emitted scintillation light, which is absorbed in a separate silicon-on-sapphire light absorber, are measured with highly sensitive transition edge sensors operated at ~15mK. The unique combination of these sensors with the light element oxygen present in our target yields sensitivity to dark matter particle masses as low as 160MeV/c2^2.Comment: 9 pages, 9 figure

    Cisplatin-DNA adduct formation in patients treated with cisplatin-based chemoradiation: lack of correlation between normal tissues and primary tumor

    Get PDF
    Contains fulltext : 69595.pdf (publisher's version ) (Closed access)PURPOSE: In this study, the formation of cisplatin-DNA adducts after concurrent cisplatin-radiation and the relationship between adduct-formation in primary tumor tissue and normal tissue were investigated. METHODS: Three intravenous cisplatin-regimens, given concurrently with radiation, were studied: daily low-dose (6 mg/m(2)) cisplatin, weekly 40 mg/m(2), three-weekly 100 mg/m(2). A (32)P-postlabeling technique was used to quantify adducts in normal tissue [white blood cells (WBC) and buccal cells] and tumor. RESULTS: Normal tissue samples for adduct determination were obtained from 63 patients and tumor biopsies from 23 of these patients. Linear relationships and high correlations were observed between the levels of two guanosine- and adenosine-guanosine-adducts in normal and tumor tissue. Adduct levels in tumors were two to five times higher than those in WBC (P<0.001). No significant correlations were found between adduct levels in normal tissues and primary tumor biopsies, nor between WBC and buccal cells. CONCLUSIONS: In concurrent chemoradiotherapy schedules, cisplatin adduct levels in tumors were significantly higher than in normal tissues (WBC). No evidence of a correlation was found between adduct levels in normal tissues and primary tumor biopsies. This lack of correlation may, to some extent, explain the inconsistencies in the literature regarding whether or not cisplatin-DNA adducts can be used as a predictive test in anticancer platinum therapy

    Environmental impact of warehousing: a scenario analysis for the United States

    Get PDF
    In recent years, there has been observed a continued growth of global carbon dioxide emissions, which are considered as a crucial factor for the greenhouse effect and associated with substantial environmental damages. Amongst others, logistic activities in global supply chains have become a major cause of industrial emissions and the progressing environmental pollution. Although a significant amount of logistic-related carbon dioxide emissions is caused by storage and material handling processes in warehouses, prior research mostly focused on the transport elements. The environmental impact of warehousing has received only little attention by research so far. Operating large and highly technological warehouses, however, causes a significant amount of energy consumption due to lighting, heating, cooling and air condition as well as fixed and mobile material handling equipment which induces considerable carbon dioxide emissions. The aim of this paper is to summarise preliminary studies of warehouse-related emissions and to discuss an integrated classification scheme enabling researchers and practitioners to systematically assess the carbon footprint of warehouse operations. Based on the systematic assessment approach containing emissions determinants and aggregates, overall warehouse emissions as well as several strategies for reducing the carbon footprint will be studied at the country level using empirical data of the United States. In addition, a factorial analysis of the warehouse-related carbon dioxide emissions in the United States enables the estimation of future developments and facilitates valuable insights for identifying effective mitigation strategies

    Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions

    Optimal Operation of Cryogenic Calorimeters Through Deep Reinforcement Learning

    Get PDF
    Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to sub-GeV/c2 dark matter interactions with nuclei in current direct detection experiments. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an expert. In our work, we automated the procedure with reinforcement learning in two settings. First, we trained on a simulation of the response of three Cryogenic Rare Event Search with Superconducting Thermometers (CRESST) detectors used as a virtual reinforcement learning environment. Second, we trained live on the same detectors operated in the CRESST underground setup. In both cases, we were able to optimize a standard detector as fast and with comparable results as human experts. Our method enables the tuning of large-scale cryogenic detector setups with minimal manual interventions

    Detector Development for the CRESST Experiment

    Get PDF
    Recently low-mass dark matter direct searches have been hindered by a low-energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of the observations. Within the CRESST collaboration, three new different detector layouts have been developed, and they are presented in this contribution

    Light dark matter search using a diamond cryogenic detector

    Get PDF
    Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. We measured two 0.175 g CVD (Chemical Vapor Deposition) diamond samples, each instrumented with a Transition Edge Sensor made of Tungsten (W-TES). Thanks to the energy threshold of just 16.8 eV of one of the two detectors, we set exclusion limits on the elastic spin-independent interaction of dark matter particles with carbon nuclei down to dark matter masses as low as 0.122 GeV/c2. This work shows the scientific potential of cryogenic detectors made from diamond and lays the foundation for the use of this material as target for direct detection dark matter experiments
    • …
    corecore