The Artelon CMC spacer compared with tendon interposition arthroplasty: A randomized, controlled, multicenter study of 109 patients with osteoarthritis followed for 1 year
Background and purpose The Artelon CMC spacer is designed for surgical treatment of osteoarthritis (OA) in the carpometacarpal joint of the thumb (CMC-I). Good results using this degradable device were previously presented in a pilot study. We now present results from a larger randomized, controlled, multicenter study
Added value of double reading in diagnostic radiology,a systematic review
Abstract Objectives Double reading in diagnostic radiology can find discrepancies in the original report, but a systematic program of double reading is resource consuming. There are conflicting opinions on the value of double reading. The purpose of the current study was to perform a systematic review on the value of double reading. Methods A systematic review was performed to find studies calculating the rate of misses and overcalls with the aim of establishing the added value of double reading by human observers. Results The literature search resulted in 1610 hits. After abstract and full-text reading, 46 articles were selected for analysis. The rate of discrepancy varied from 0.4 to 22% depending on study setting. Double reading by a sub-specialist, in general, led to high rates of changed reports. Conclusions The systematic review found rather low discrepancy rates. The benefit of double reading must be balanced by the considerable number of working hours a systematic double-reading scheme requires. A more profitable scheme might be to use systematic double reading for selected, high-risk examination types. A second conclusion is that there seems to be a value of sub-specialisation for increased report quality. A consequent implementation of this would have far-reaching organisational effects. Key Points • In double reading, two or more radiologists read the same images. • A systematic literature review was performed. • The discrepancy rates varied from 0.4 to 22% in various studies. • Double reading by sub-specialists found high discrepancy rates
99mTc-MIBI Embolus in the Late Phase of a Parathyroid Scan
We report a case of a transient focal MIBI uptake in the late, 90 minutes postinjection phase of a parathyroid scintigraphy in which SPECT/CT imaging proved valuable in delineating the nature of this incidental finding.</p
Somatostatin receptor PET/CT in neuroendocrine tumours: update on systematic review and meta-analysis
Purpose Neuroendocrine tumours (NET) are uncommon and may be localized in many different places in the body. Traditional imaging has mainly been performed with CT and somatostatin receptor scintigraphy (SRS). Recently, it has become possible to use somatostatin receptor PET/CT (SMSR PET) instead, which might improve diagnostic quality. To evaluate the diagnostic quality of SMSR PET we performed a meta-analysis as an update of a previous study published in 2012. A literature search was performed searching MEDLINE, Embase and five other databases with a combination of the expressions "PET", "positron emission tomography", "neuroendocrine" and "NET". The search was updated to 31 December 2012. Studies were selected which evaluated the sensitivity and specificity of SMSR PET for NET in the thorax or abdomen with a study size of at least eight patients. The methodological quality of the included studies was evaluated with QUADAS-2. Eight studies fulfilled the inclusion criteria and were selected for final analysis, and 14 articles from a previous meta-analysis were added for a total of 22 articles. A total of 2,105 patients were included in the studies, an increase from 567 in the previous meta-analysis. The pooled sensitivity was 93 % (95 % CI 91 - 94 %) and specificity 96 % (95 % CI 95 - 98 %). The area under the summary ROC curve was 0.98 (95 % CI 0.95 - 1.0). In the previous meta-analysis the pooled sensitivity was 93 % (95 % CI 91 - 95 %) and specificity 91 % (95 % CI 82 - 97 %). SMSR PET has good diagnostic performance for evaluation of NET in the thorax and abdomen, better than SRS which has been the previous standard method. This meta-analysis gives further support for switching to SMSR PET.</p
Low-dose computed tomography of the lumbar spine: a phantom study on imaging parameters and image quality
Tomosynthesis of the thoracic spine : added value in diagnosing vertebral fractures in the elderly
Objectives: Thoracic spine radiography becomes more difficult with age. Tomosynthesis is a low-dose tomographic extension of radiography which may facilitate thoracic spine evaluation. This study assessed the added value of tomosynthesis in imaging of the thoracic spine in the elderly. Methods: Four observers compared the image quality of 50 consecutive thoracic spine radiography and tomosynthesis data sets from 48 patients (median age 67 years, range 55–92 years) on a number of image quality criteria. Observer variation was determined by free-marginal multirater kappa. The conversion factor and effective dose were determined from the dose–area product values. Results: For all observers significantly more vertebrae were seen with tomosynthesis than with radiography (mean 12.4/9.3, P <0.001) as well as significantly more fractures (mean 0.9/0.7, P = 0.017). The image quality score for tomosynthesis was significantly higher than for radiography, for all evaluated structures. Tomosynthesis took longer to evaluate than radiography. Despite this, all observers scored a clear preference for tomosynthesis. Observer agreement was substantial (mean κ = 0.73, range 0.51–0.94). The calibration or conversion factor was 0.11 mSv/(Gy cm2) for the combined examination. The resulting effective dose was 0.87 mSv. Conclusion: Tomosynthesis can increase the detection rate of thoracic vertebral fractures in the elderly, at low added radiation dose. Key Points: • Tomosynthesis helps evaluate the thoracic spine in the elderly.• Observer agreement for thoracic spine tomosynthesis was substantial (mean κ = 0.73).• Significantly more vertebrae and significantly more fractures were seen with tomosynthesis.• Tomosynthesis took longer to evaluate than radiography.• There was a clear preference among all observers for tomosynthesis over radiography
Making renal stones change size—impact of CT image post processing and reader variability
Objectives The objectives of this study were to quantify the impact of image post-processing parameters on the apparent renal stone size, and to quantify the intra- and inter-reader variability in renal stone size estimation. Methods Fifty CT datasets including a renal or ureteral stone were included retrospectively during a prospective inclusion period. Each of the CT datasets was post-processed in different ways regarding slice thickness, slice increment and window setting. In the first part of the study a single reader repeated size estimations for the renal stones using different post-processing parameters. In the intra-reader variability experiment one reader reported size estimations for the same images with a one-week interval. The inter-reader variability data were obtained from 11 readers reporting size estimations for the same renal stones. Results The apparent stone size differed according to image post-processing parameters with the largest mean differences seen with regard to the window settings experiment (1.5 mm, p < 0.001) and slice thickness (0.8 mm, p < 0.001). Changes in parameters introduced a bias and a pseudo-random variability. The inter-reader variability was considerably larger than the intra-reader variability. Conclusion Our results indicate a need for the standardisation of making measurements on CT images.</p
Low-dose computed tomography of the abdomen and lumbar spine [Elektronisk resurs]
Radiography is a common radiologic investigation despite abundant evidence of its limited diagnostic value. On the other hand, computed tomography (CT) has a high diagnostic value and is widely considered to be among the most important advances in medicine. However, CT exposes patients to a higher radiation dose and it might therefore not be acceptable simply to replace radiography with CT, despite the powerful diagnostic value of this technique. At the expense of reduced CT image quality, which could be adjusted to the diagnostic needs, low-dose CT of abdomen and lumbar spine can be performed at similar dose to radiography. The aim of the current thesis project was to evaluate low-dose CT of the abdomen and lumbar spine and to compare it with radiography. The hypothesis was that CT would give better image quality and diagnostic information compared to radiography at similar dose levels. Firstly, the diagnostic accuracy of low-dose CT of the abdomen was evaluated. Results showed that low-dose CT of abdomen has a high sensitivity and specificity compared to radiography, i.e., it has higher diagnostic accuracy. Similar results were obtained from our systematic review. Secondly, in a phantom study, an ovine phantom was scanned at various CT settings. The image quality was evaluated to obtain a protocol for the optimal settings for low-dose CT of lumbar spine at 1 mSv. This new protocol was then used in a clinical study to assess the image quality of low-dose CT of the lumbar spine and compare it to radiography. Results showed that low-dose CT has significantly better image quality than radiography. Finally, the impact of Iterative reconstruction (IR) on image quality of lumbar spine CT was tested. Iterative reconstruction is a recent CT technique aimed to reduce radiation dose and/or improve image quality. The results showed that the use of medium strength IR levels in the reconstruction of CT image improves image quality compared to filtered back projection. In conclusion, low-dose CT of the abdomen and lumbar spine, at about 1 mSv, has better image quality and gives diagnostic information compared to radiography at similar dose levels and it could therefore replace radiography.</p
Dendrochronology with a medical X-ray photon counting computed tomography scanner
Dendrochronology traditionally involves invasive techniques that might harm cultural heritage artifacts. Non-invasive approaches using X-ray technology and computed tomography (CT) have emerged, but dedicated CT systems are limited in availability. This study explored the viability of using a recently developed photon counting medical CT scanner for growth ring analysis. Six wood samples from pine, oak and beech with varying growth rates were studied. Comparisons were made between traditional methods and CT scanning with measurements performed on the untreated surface, a prepared surface and on CT images. For samples with annual rings wider than 0.3–0.4 mm, CT scanning performed well, while samples with thinner rings or indistinct ring boundaries presented challenges. The combination of traditional tree-ring measurements and analyses of CT scanned images might be a superior study approach generating extra data and information
- …