86 research outputs found
Bileaf mechanical strain gage
Bileaf lever detects small deformations by highly magnifying linear displacements. Device is applicable to force measuring instruments, pressure cells, temperature gages, existing strain gages, dial gages, or extensometers. Additional magnification is obtained by cementing a small mirror to mobile end of bileaf
Simple method for forming thin-wall pressure vessels
Application of internal hydrostatic pressure to seam-welded circular cylindrical tanks having corner-welded, flat, circular ends forms large thin-walled high quality tanks. Form limits expansion of cylindrical portion of final tank while hemispherical ends develop freely; no external form or restraint is required to fabricate spherical tanks
Metal tube used as solar engine
Ends of metal tube are fastened to axles which are supported on bearings so tube can rotate about its long axis while subjected to invariant bending moment that stresses it along longitudinal axis of rotation. Heat absorbed leads to expansion of metal, which unbalances internal forces and generates rotational moment in tube
Solid medium thermal engine
A device is described which uses a single phase metallic working substance to convert thermal energy directly into mechanical energy. The device consists of a cylindrical metal tube which is free to rotate about its axis while being subjected to continuous bending moment stresses along the longitudinal axis of rotation. The stressing causes portions of the tube to be under compression while other parts are under tension which in turn causes the tube to rotate and provide mechanical energy
Matching experimental and three dimensional numerical models for structural vibration problems with uncertainties
© 2017 The Author(s) The simulation model which examines the dynamic behavior of real structures needs to address the impact of uncertainty in both geometry and material parameters. This article investigates three-dimensional finite element models for structural dynamics problems with respect to both model and parameter uncertainties. The parameter uncertainties are determined via laboratory measurements on several beam-like samples. The parameters are then considered as random variables to the finite element model for exploring the uncertainty effects on the quality of the model outputs, i.e. natural frequencies. The accuracy of the output predictions from the model is compared with the experimental results. To this end, the non-contact experimental modal analysis is conducted to identify the natural frequency of the samples. The results show a good agreement compared with experimental data. Furthermore, it is demonstrated that geometrical uncertainties have more influence on the natural frequencies compared to material parameters and material uncertainties are about two times higher than geometrical uncertainties. This gives valuable insights for improving the finite element model due to various parameter ranges required in a modeling process involving uncertainty
A Robust Open-source Tendon-driven Robot Arm for Learning Control of Dynamic Motions
A long-lasting goal of robotics research is to operate robots safely, while
achieving high performance which often involves fast motions. Traditional
motor-driven systems frequently struggle to balance these competing demands.
Addressing this trade-off is crucial for advancing fields such as manufacturing
and healthcare, where seamless collaboration between robots and humans is
essential. We introduce a four degree-of-freedom (DoF) tendon-driven robot arm,
powered by pneumatic artificial muscles (PAMs), to tackle this challenge. Our
new design features low friction, passive compliance, and inherent impact
resilience, enabling rapid, precise, high-force, and safe interactions during
dynamic tasks. In addition to fostering safer human-robot collaboration, the
inherent safety properties are particularly beneficial for reinforcement
learning, where the robot's ability to explore dynamic motions without causing
self-damage is crucial. We validate our robotic arm through various
experiments, including long-term dynamic motions, impact resilience tests, and
assessments of its ease of control. On a challenging dynamic table tennis task,
we further demonstrate our robot's capabilities in rapid and precise movements.
By showcasing our new design's potential, we aim to inspire further research on
robotic systems that balance high performance and safety in diverse tasks. Our
open-source hardware design, software, and a large dataset of diverse robot
motions can be found at https://webdav.tuebingen.mpg.de/pamy2/
Experimental/analytical approach to understanding mistuning in a transonic wind tunnel compressor
This paper will briefly set forth some of the basic tenets of mistuned rotating bladed-disk assemblies. The experience with an existing three stage compressor in a transonic wind tunnel will be documented. The manner in which the theoretical properties manifest themselves in this non-ideal compressor will be described. A description of mistuning behaviors that can and cannot be accurately substantiated will be discussed
Systematic Review to Inform a World Health Organization (WHO) Clinical Practice Guideline: Benefits and Harms of Transcutaneous Electrical Nerve Stimulation (TENS) for Chronic Primary Low Back Pain in Adults
PURPOSE: To evaluate benefits and harms of transcutaneous electrical nerve stimulation (TENS) for chronic primary low back pain (CPLBP) in adults to inform a World Health Organization (WHO)Â standard clinical guideline.
METHODS: We searched for randomized controlled trials (RCTs) from various electronic databases from July 1, 2007 to March 9, 2022. Eligible RCTs targeted TENS compared to placebo/sham, usual care, no intervention, or interventions with isolated TENS effects (i.e., combined TENS with treatment B versus treatment B alone) in adults with CPLBP. We extracted outcomes requested by the WHO Guideline Development Group, appraised the risk of bias, conducted meta-analyses where appropriate, and graded the certainty of evidence using GRADE.
RESULTS: Seventeen RCTs (adults, n = 1027; adults ≥ 60 years, n = 28) out of 2010 records and 89 full text RCTs screened were included. The evidence suggested that TENS resulted in a marginal reduction in pain compared to sham (9 RCTs) in the immediate term (2 weeks) (mean difference (MD) = -0.90, 95% confidence interval  -1.54 to -0.26), and a reduction in pain catastrophizing in the short term (3 months) with TENS versus no intervention or interventions with TENS specific effects (1 RCT) (MD = -11.20, 95% CI -17.88 to -3.52). For other outcomes, little or no difference was found between TENS and the comparison interventions. The certainty of the evidence for all outcomes was very low.
CONCLUSIONS: Based on very low certainty evidence, TENS resulted in brief and marginal reductions in pain (not deemed clinically important) and a short-term reduction in pain catastrophizing in adults with CPLBP, while little to no differences were found for other outcomes
Systematic Review to Inform a World Health Organization (WHO) Clinical Practice Guideline: Benefits and Harms of Needling Therapies for Chronic Primary Low Back Pain in Adults
PURPOSE
Evaluate benefits and harms of needling therapies (NT) for chronic primary low back pain (CPLBP) in adults to inform a World Health Organization (WHO) standard clinical guideline.
METHODS
Electronic databases were searched for randomized controlled trials (RCTs) assessing NT compared with placebo/sham, usual care, or no intervention (comparing interventions where the attributable effect could be isolated). We conducted meta-analyses where indicated and graded the certainty of evidence.
RESULTS
We screened 1831 citations and 109 full text RCTs, yeilding 37 RCTs. The certainty of evidence was low or very low across all included outcomes. There was little or no difference between NT and comparisons across most outcomes; there may be some benefits for certain outcomes. Compared with sham, NT improved health-related quality of life (HRQoL) (physical) (2 RCTs; SMD = 0.20, 95%CI 0.07; 0.32) at 6 months. Compared with no intervention, NT reduced pain at 2 weeks (21 RCTs; MD = - 1.21, 95%CI - 1.50; - 0.92) and 3 months (9 RCTs; MD = - 1.56, 95%CI - 2.80; - 0.95); and reduced functional limitations at 2 weeks (19 RCTs; SMD = - 1.39, 95%CI - 2.00; - 0.77) and 3 months (8 RCTs; SMD = - 0.57, 95%CI - 0.92; - 0.22). In older adults, NT reduced functional limitations at 2 weeks (SMD = - 1.10, 95%CI - 1.71; - 0.48) and 3 months (SMD = - 1.04, 95%CI - 1.66; - 0.43). Compared with usual care, NT reduced pain (MD = - 1.35, 95%CI - 1.86; - 0.84) and functional limitations (MD = - 2.55, 95%CI - 3.70; - 1.40) at 3 months.
CONCLUSION
Based on low to very low certainty evidence, adults with CPLBP experienced some benefits in pain, functioning, or HRQoL with NT; however, evidence showed little to no differences for other outcomes
- …