2,886 research outputs found
Thermal stability of a strip crystal for channeling of halo particles in the Large Hadron Collider
For possible application of a silicon bent crystal as a beam collimator in the Large Hadron Collider, the thermal stability of a strip-like crystal has been studied. The thermal power generated by the beam inside the crystal has been evaluated through a simulation and used as a source in the heat equation. The equation has been solved numerically with the semi-analytical method of lines to show the thermal stability of crystal-assisted collimation with the parameters currently being considered for its exploitation. The method we presented appears to be useful for calculation of the thermal load concerning any situation involving Crystal channeling
A model for the interaction of high-energy particles in straight and bent crystals implemented in Geant4
A model for the simulation of orientational effects in straight and bent
periodic atomic structures is presented. The continuum potential approximation
has been adopted.The model allows the manipulation of particle trajectories by
means of straight and bent crystals and the scaling of the cross sections of
hadronic and electromagnetic processes for channeled particles. Based on such a
model, an extension of the Geant4 toolkit has been developed. The code has been
validated against data from channeling experiments carried out at CERN
Low-latency analysis pipeline for compact binary coalescences in the advanced gravitational wave detector era
The multi-band template analysis (MBTA) pipeline is a low-latency coincident
analysis pipeline for the detection of gravitational waves (GWs) from compact
binary coalescences. MBTA runs with a low computational cost, and can identify
candidate GW events online with a sub-minute latency. The low computational
running cost of MBTA also makes it useful for data quality studies. Events
detected by MBTA online can be used to alert astronomical partners for
electromagnetic follow-up. We outline the current status of MBTA and give
details of recent pipeline upgrades and validation tests that were performed in
preparation for the first advanced detector observing period. The MBTA pipeline
is ready for the outset of the advanced detector era and the exciting prospects
it will bring.Comment: 18 pages, 10 figure
Crystal experiments on efficient beam extraction
Silicon crystal was channeling and extracting 70-GeV protons from the U-70
accelerator with efficiency of 85.3+-2.8% as measured for a beam of 10^12
protons directed towards crystals of 2 mm length in spills of 1-2 s duration.
The experimental data follow very well the prediction of Monte Carlo
simulations. This success is important to devise a more efficient use of the
U-70 accelerator in Protvino and provides a crucial support for implementation
of crystal-assisted collimation of gold ion beam in RHIC and slow extraction
from AGS onto E952, now in preparation at Brookhaven Nat'l Lab. Future
applications, spanning in the energy from sub-GeV (medical) to order of 1 GeV
(scraping in the SNS, extraction from COSY) to order of 1 TeV and beyond
(scraping in the Tevatron, LHC, VLHC), can benefit from these studies.Comment: 12pp. Presented at 19-th Intern. Conference on Atomic Collisions in
Solids (ICACS-19: Paris, July 29 - August 3, 2001
Progress in crystal extraction and collimation
Recent IHEP Protvino experiments show efficiencies of crystal-assisted slow
extraction and collimation of 85.3+-2.8%, at the intensities of the channeled
beam on the order of 10^12 proton per spill of 2 s duration. The obtained
experimental data well follows the theory predictions. We compare the
measurements against theory and outline the theoretical potential for further
improvement in the efficiency of the technique. This success is important for
the efficient use of IHEP accelerator and for implementation of
crystal-assisted collimation at RHIC and slow extraction from AGS onto E952,
now in preparation. Future applications, spanning in the energy from order of 1
GeV (scraping in SNS, slow extraction from COSY and medical accelerators) to
order of 1 TeV and beyond (scraping in Tevatron, LHC, VLHC), can benefit from
these studies.Comment: 7pp. Presented at HEACC 2001 (Tsukuba, March 25-30
Channeling of high energy beams in nanotubes
We present simulations of particle beam channeling in carbon nanotubes and evaluate the possibilities for experimental observation of channeling effect in straight and bent nanotubes at IHEP and LNF. Different particle species are considered: protons of 1.3 and 70 GeV, and positrons of 0.5 GeV. Predictions are made for the experiments, with analysis of requirements on the quality of nanosamples and resolution of the experimental set-up. Based on Monte Carlo simulations, the capabilities of nanotube channeling technique for particle beam steering are discussed
Experimental evidence of planar channeling in a periodically bent crystal
The usage of a Crystalline Undulator (CU) has been identified as a promising
solution for generating powerful and monochromatic -rays. A CU was
fabricated at SSL through the grooving method, i.e., by the manufacturing of a
series of periodical grooves on the major surfaces of a crystal. The CU was
extensively characterized both morphologically via optical interferometry at
SSL and structurally via X-ray diffraction at ESRF. Then, it was finally tested
for channeling with a 400 GeV/c proton beam at CERN. The experimental results
were compared to Monte Carlo simulations. Evidence of planar channeling in the
CU was firmly observed. Finally, the emission spectrum of the positron beam
interacting with the CU was simulated for possible usage in currently existing
facilities
The Investigations Of Beam Extraction And Collimation At U-70 Proton Synchrotron Of IHEP By Using Short Silicon Crystals
The new results of using short (2-4mm) bent crystals for extraction and
collimation of proton beam at IHEP 70 Gev proton synchrotron are reported. A
broad range of energies from 6 to 65 GeV has been studied in the same crystal
collimation set-up. The efficiency of extraction more than 85% and intensity
more than 10E12 were obtained by using crystal with the length 2-mm and the
angle 1 mrad. The new regime of extraction is applied now at the accelerator to
deliver the beam for different experimental setups within the range of
intensity 10E7-10E12ppp.Comment: Presented at EPAC 2002 (Paris, June 3-7), 3p
Acute myocardial infarction following off label retrobulbar injection of desmopressin for non-arteritic anterior ischemic optic neuropathy (NAION). Causal correlation or coincidence?
A 60-year-old man, apparently healthy with negative history for cardiovascular diseases, was hospitalized because of an unilateral sudden and painless severe visual loss. Diagnosis of NAION was made. Two separate and immediately consecutive injections of betamethasone (2 mg/0.5 mL) and desmopressin (2 mcg/0.5 mL) were performed in the retrobulbar space. Fifteen minutes later, the patient suddenly developed cold sweat, dyspnoea, thoracic pain and severe hypotension. Acute myocardial infarction was diagnosed by ECG. Desmopressin was the probable causative agent. Thrombotic events following intravenous or oral administration of desmopressin have been documented in the medical literature. To the best of our knowledge this is the first case in which a thrombotic event was associated with the retrobulbar route.
Retrobulbar desmopressin administration in patients with NAION can be probably associated with AMI. Considering its invasiveness and the unproven benefit in the treatment of NAION, this therapeutic approach can not be currently recommende
- âŠ