356 research outputs found

    Development of a fast curing tissue adhesive for meniscus tear repair

    Get PDF
    Isocyanate-terminated adhesive amphiphilic block copolymers are attractive materials to treat meniscus tears due to their tuneable mechanical properties and good adhesive characteristics. However, a drawback of this class of materials is their relatively long curing time. In this study, we evaluate the use of an amine cross-linker and addition of catalysts as two strategies to accelerate the curing rates of a recently developed biodegradable reactive isocyanate-terminated hyper-branched adhesive block copolymer prepared from polyethylene glycol (PEG), trimethylene carbonate, citric acid and hexamethylene diisocyanate. The curing kinetics of the hyper-branched adhesive alone and in combination with different concentrations of spermidine solutions, and after addition of 2,2-dimorpholinodiethylether (DMDEE) or 1,4-diazabicyclo [2.2.2] octane (DABCO) were determined using FTIR. Additionally, lap-shear adhesion tests using all compositions at various time points were performed. The two most promising compositions of the fast curing adhesives were evaluated in a meniscus bucket handle lesion model and their performance was compared with that of fibrin glue. The results showed that addition of both spermidine and catalysts to the adhesive copolymer can accelerate the curing rate and that firm adhesion can already be achieved after 2 h. The adhesive strength to meniscus tissue of 3.2–3.7 N was considerably higher for the newly developed compositions than for fibrin glue (0.3 N). The proposed combination of an adhesive component and a cross-linking component or catalyst is a promising way to accelerate curing rates of isocyanate-terminated tissue adhesives

    Enzymatic post-crosslinking of printed hydrogels of methacrylated gelatin and tyramine-conjugated 8-arm poly(ethylene glycol) to prepare interpenetrating 3D network structures

    Get PDF
    Methacrylated gelatin (GelMA) has been intensively studied as a 3D printable scaffold material in tissue regeneration fields, which can be attributed to its well-known biological functions. However, the long-term stability of photo-crosslinked GelMA scaffolds is hampered by a combination of its fast degradation in the presence of collagenase and the loss of physical crosslinks at higher temperatures. To increase the longer-term shape stability of printed scaffolds, a mixture of GelMA and tyramine-conjugated 8-arm PEG (8PEGTA) was used to create filaments composed of an interpenetrating network (IPN). Photo-crosslinking during filament deposition of the GelMA and subsequent enzymatic crosslinking of the 8PEGTA were applied to the printed 3D scaffolds. Although both crosslinking mechanisms are radical based, they operate without interference of each other. Rheological data of bulk hydrogels showed that the IPN was an elastic hydrogel, having a storage modulus of 6 kPa, independent of temperature in the range of 10 – 40°C. Tensile and compression moduli were 110 kPa and 80 kPa, respectively. On enzymatic degradation in the presence of collagenase, the gelatin content of the IPN fully degraded in 7 days, leaving a stable secondary crosslinked 8PEGTA network. Using a BioMaker bioprinter, hydrogels without and with human osteosarcoma cells (hMG-63) were printed. On culturing for 21 days, hMG-63 in the GelMA/8PEGTA IPN showed a high cell viability (&gt;90%). Thus, the presence of the photoinitiator, incubation with H2O2, and mechanical forces during printing did not hamper cell viability. This study shows that the GelMA/8PEGTA ink is a good candidate to generate cell-laden bioinks for extrusion-based printing of constructs for tissue engineering applications.</p

    Amphiphilic poly(ether ester amide) multiblock copolymers as biodegradable matrices for the controlled release of proteins

    Get PDF
    Amphiphilic poly(ether ester amide) (PEEA) multiblock copolymers were synthesized by polycondensation in the melt from hydrophilic poly(ethylene glycol) (PEG), 1,4-dihydroxybutane and short bisester-bisamide blocks. These amide blocks were prepared by reaction of 1,4-diaminobutane with dimethyl adipate in the melt. A range of multiblock copolymers were prepared, with PEG contents varying from 23-66 wt %. The intrinsic viscosity of the PEEA polymers varied from 0.58-0.78. Differential scanning calorimetry showed melting transitions for the PEG blocks and for the amide-ester blocks, suggesting a phase separated structure. Both the melting temperature and the crystallinity of the hard amide-ester segments decreased with increasing PEG content of the polymers. The equilibrium swelling ratio in phosphate buffered saline (PBS) increased with increasing amount of PEG in the polymers and varied from 1.7 to 3.7, whereas the polymer that contained 66 wt % PEG was soluble in PBS. During incubation of PEEA films in PBS, weight loss and a continuous decrease in the resulting inherent polymer viscosity was observed. The rate of degradation increased with increasing PEG content. The composition of the remaining matrices did not change during degradation. A preliminary investigation of the protein release characteristics of these PEEA copolymers showed that release of the model protein lysozyme was proportional to the square root of time. The release rate was found to increase with increasing degree of swelling of the polymers

    In Vitro and In Vivo Degradation of Photo‐Crosslinked Poly(Trimethylene Carbonate‐co‐Δ‐Caprolactone) Networks

    Get PDF
    Three-armed poly(trimethylene carbonate) (PTMC) and poly(trimethylene carbonate-co-Ɛ-caprolactone) (P(TMC-co-Δ-CL)) macromers with molecular weights of approximately 30 kg mol−1 are synthesized by ring-opening polymerization and subsequent functionalization with methacrylic anhydride. Networks are then prepared by photo-crosslinking. To investigate the in vitro and in vivo degradation properties of these photo-crosslinked networks and assess the effect of Δ-caprolactone content on the degradation properties, PTMC networks, and copolymer networks with two different TMC:Δ-CL ratios are prepared. PTMC networks degraded slowly, via an enzymatic surface erosion process, both in vitro and in vivo. Networks prepared from P(TMC-co-Δ-CL) macromers with a 74:26 ratio are found to degrade slowly as well, via a surface erosion process, albeit at a higher rate compared to PTMC networks. Increasing the Δ-CL content to a ratio of 52:48, resulted in a faster degradation. These networks lost their mechanical properties much sooner than the other networks. Thus, PTMC and P(TMC-co-Δ-CL) networks are interesting networks for tissue engineering purposes and the exact degradation properties can be tuned by varying the TMC:Δ-CL ratio, providing researchers with a tool to obtain copolymer networks with the desired degradation rate depending on the intended application

    Surface Curvature Differentially Regulates Stem Cell Migration and Differentiation via Altered Attachment Morphology and Nuclear Deformation

    Get PDF
    Signals from the microenvironment around a cell are known to influence cell behavior. Material properties, such as biochemical composition and substrate stiffness, are today accepted as significant regulators of stem cell fate. The knowledge of how cell behavior is influenced by 3D geometric cues is, however, strongly limited despite its potential relevance for the understanding of tissue regenerative processes and the design of biomaterials. Here, the role of surface curvature on the migratory and differentiation behavior of human mesenchymal stem cells (hMSCs) has been investigated on 3D surfaces with well-defined geometric features produced by stereolithography. Time lapse microscopy reveals a significant increase of cell migration speed on concave spherical compared to convex spherical structures and flat surfaces resulting from an upward-lift of the cell body due to cytoskeletal forces. On convex surfaces, cytoskeletal forces lead to substantial nuclear deformation, increase lamin-A levels and promote osteogenic differentiation. The findings of this study demonstrate a so far missing link between 3D surface curvature and hMSC behavior. This will not only help to better understand the role of extracellular matrix architecture in health and disease but also give new insights in how 3D geometries can be used as a cell-instructive material parameter in the field of biomaterial-guided tissue regeneration.Peer reviewe

    Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery:A goat model with four years follow-up

    Get PDF
    Applying biodegradable osteosyntheses avoids the disadvantages of titanium osteosyntheses. However, foreign-body reactions remain a major concern and evidence of complete resorption is lacking. This study compared the physico-chemical properties, histological response and radiographs of four copolymeric biodegradable osteosynthesis systems in a goat model with 48-months follow-up. The systems were implanted subperiosteally in both tibia and radius of 12 Dutch White goats. The BioSorb FX [poly(70LLA-co-30DLLA)], Inion CPS [poly([70-78.5]LLA-co-[16-24]DLLA-co-4TMC)], SonicWeld Rx [poly(DLLA)], LactoSorb [poly(82LLA-co-18GA)] systems and a negative control were randomly implanted in each extremity. Samples were assessed at 6-, 12-, 18-, 24-, 36-, and 48-month follow-up. Surface topography was performed using scanning electron microscopy (SEM). Differential scanning calorimetry and gel permeation chromatography were performed on initial and explanted samples. Histological sections were systematically assessed by two blinded researchers using (polarized) light microscopy, SEM and energy-dispersive X-ray analysis. The SonicWeld Rx system was amorphous while the others were semi-crystalline. Foreign-body reactions were not observed during the complete follow-up. The SonicWeld Rx and LactoSorb systems reached bone percentages of negative controls after 18 months while the BioSorb Fx and Inion CPS systems reached these levels after 36 months. The SonicWeld Rx system showed the most predictable degradation profile. All the biodegradable systems were safe to use and well-tolerated (i.e., complete implant replacement by bone, no clinical or histological foreign body reactions, no [sterile] abscess formation, no re-interventions needed), but nanoscale residual polymeric fragments were observed at every system's assessment
    • 

    corecore