2,307 research outputs found

    A Multi-coloured survey of NGC 253 with XMM-Newton

    Full text link
    There is a large body of work that has used the excellent Chandra observations of nearby galaxies with neglible low mass X-ray binary (LMXB) populations. This has culminated in a ``Universal'' X-ray luminosity function (XLF) for high mass X-ray binaries (HMXBs). However, a number of methods have been used to convert from source intensities to luminosities when creating these XLFs. We have taken advantage of the XMM-Newton observations of the nearby starbursting spiral galaxy NGC 253 to test some of these methods. We find the luminosities derived from these various methods to vary by a factor of \sim3. We also find the most influential factor in the conversion from intensity to luminosity to be the absorption. We therefore conclude that a more consistent approach is required for determining the true Universal XLF for HMXBs. Ideally, this would involve individual spectral fitting of each X-ray source. Certainly, the line-of-sight absorption should be determined from the observations rather than assuming Galactic absorption. We find the best approach for obtaining an XLF from low-count data to be the splitting of the X-ray sources into two or more intensity intervals, and obtaining a conversion from intensity to flux for each group from spectral modelling of the summed spectrum of that group.Comment: To appear in the proceedings of "X-rays from Nearby Galaxies", 4-7 Septembeer 2007, 4 page

    Cumulative luminosity functions of the X-ray point source population in M31

    Full text link
    We present preliminary results from a detailed analysis of the X-ray point sources in the XMM-Newton survey of M31. These sources are expected to be mostly X-ray binaries. We have so far studied 225 of the 535 sources found by automated source detection. Only sources which were present in all three EPIC images were considered. X-ray binaries are identified by their energy spectrum and power density spectrum. Unlike in other surveys we have obtained source luminosities from freely fit emission models. We present uncorrected luminosity functions of the sources analysed so far.Comment: 2 pages, 1 figure. To appear in proceedings of IAUS23

    XMM-Newton reveals ~100 new LMXBs in M31 from variability studies

    Full text link
    We have conducted a survey of X-ray sources in XMM-Newton observations of M31, examining their power density spectra (PDS) and spectral energy distributions (SEDs). Our automated source detection yielded 535 good X-ray sources; to date, we have studied 225 of them. In particular, we examined the PDS because low mass X-ray binaries (LMXBs) exhibit two distinctive types of PDS. At low accretion rates, the PDS is characterised by a broken power law, with the spectral index changing from ~0 to ~1 at some frequency in the range \~0.01--1 Hz; we refer to such PDS as Type A. At higher accretion rates, the PDS is described by a simple power law; we call these PDS Type B. Of the 225 sources studied to date, 75 exhibit Type A variability, and are almost certainly LMXBs, while 6 show Type B but not Type A, and are likely LMXBs. Of these 81 candidate LMXBs, 71 are newly identified in this survey; furthermore, they are mostly found near the centre of M31. Furthermore, most of the X-ray population in the disc are associated with the spiral arms, making them likely high mass X-ray binaries (HMXBs). In general these HMXBs do not exhibit Type A variability, while many central X-ray sources (LMXBs) in the same luminosity range do. Hence the PDS may distinguish between LMXBs and HMXBs in this luminosity range.Comment: 4 pages, 2 figures. To appear in proceedings of IAUS230: "Populations of High Energy Sources in Galaxies", 14-19 August 2005, Dublin, Eds E.J.A. Meurs and G. Fabbian

    Self-referenced characterization of space-time couplings in near single-cycle laser pulses

    Get PDF
    We report on the characterization of space-time couplings in high energy sub-2-cycle 770nm laser pulses using a self-referencing single-shot method. Using spatially-encoded arrangement filter-based spectral phase interferometry for direct electric field reconstruction (SEA-F-SPIDER) we characterize few-cycle pulses with a wave-front rotation of 2.8x?10^11 rev/sec (1.38 mrad per half-cycle) and pulses with pulse front tilts ranging from to -0.33 fs/um to -3.03 fs/um.Comment: 6 pages, 6 figure

    Analysis and design of on-grade reinforced concrete track support structures

    Get PDF
    For the improvement of rail service, the Department of Transportation, Federal Rail Administration, is sponsoring a test track on the Atchison, Topeka, and Santa Fe Railway. The test track will contain nine separate rail support structures, including one conventional section for control and three reinforced concrete structures on grade, one slab and two beam sections. The analysis and design of these latter structures was accomplished by means of the finite element method, NASTRAN, and is presented

    Shoulder posture and median nerve sliding

    Get PDF
    Background: Patients with upper limb pain often have a slumped sitting position and poorshoulder posture. Pain could be due to poor posture causing mechanical changes (stretch; localpressure) that in turn affect the function of major limb nerves (e.g. median nerve). This studyexamines (1) whether the individual components of slumped sitting (forward head position, trunkflexion and shoulder protraction) cause median nerve stretch and (2) whether shoulderprotraction restricts normal nerve movements.Methods: Longitudinal nerve movement was measured using frame-by-frame cross-correlationanalysis from high frequency ultrasound images during individual components of slumped sitting.The effects of protraction on nerve movement through the shoulder region were investigated byexamining nerve movement in the arm in response to contralateral neck side flexion.Results: Neither moving the head forward or trunk flexion caused significant movement of themedian nerve. In contrast, 4.3 mm of movement, adding 0.7% strain, occurred in the forearm duringshoulder protraction. A delay in movement at the start of protraction and straightening of thenerve trunk provided evidence of unloading with the shoulder flexed and elbow extended and thescapulothoracic joint in neutral. There was a 60% reduction in nerve movement in the arm duringcontralateral neck side flexion when the shoulder was protracted compared to scapulothoracicneutral.Conclusion: Slumped sitting is unlikely to increase nerve strain sufficient to cause changes tonerve function. However, shoulder protraction may place the median nerve at risk of injury, sincenerve movement is reduced through the shoulder region when the shoulder is protracted andother joints are moved. Both altered nerve dynamics in response to moving other joints and localchanges to blood supply may adversely affect nerve function and increase the risk of developingupper quadrant pain

    Evaporative CO2 cooling using microchannels etched in silicon for the future LHCb vertex detector

    Full text link
    The extreme radiation dose received by vertex detectors at the Large Hadron Collider dictates stringent requirements on their cooling systems. To be robust against radiation damage, sensors should be maintained below -20 degree C and at the same time, the considerable heat load generated in the readout chips and the sensors must be removed. Evaporative CO2 cooling using microchannels etched in a silicon plane in thermal contact with the readout chips is an attractive option. In this paper, we present the first results of microchannel prototypes with circulating, two-phase CO2 and compare them to simulations. We also discuss a practical design of upgraded VELO detector for the LHCb experiment employing this approach.Comment: 12 page

    Single maintenance and reliever therapy (SMART) of asthma: a critical appraisal

    Get PDF
    The use of a combination inhaler containing budesonide and formoterol as both maintenance and quick relief therapy (SMART) has been recommended as an improved method of using inhaled corticosteroid/long-acting β agonist (ICS/LABA) therapy. Published double-blind trials show that budesonide/formoterol therapy delivered in SMART fashion achieves better asthma outcomes than budesonide monotherapy or lower doses of budesonide/formoterol therapy delivered in constant dosage. Attempts to compare budesonide/formoterol SMART therapy with regular combination ICS/LABA dosing using other compounds have been confounded by a lack of blinding and unspecified dose adjustment strategies. The asthma control outcomes in SMART-treated patients are poor; it has been reported that only 17.1% of SMART-treated patients are controlled. In seven trials of 6–12 months duration, patients using SMART have used quick reliever daily (weighted average 0.92 inhalations/day), have awakened with asthma symptoms once every 7–10 days (weighted average 11.5% of nights), have suffered asthma symptoms more than half of days (weighted average 54.0% of days) and have had a severe exacerbation rate of one in five patients per year (weighted average 0.22 severe exacerbations/patient/year). These poor outcomes may reflect the recruitment of a skewed patient population. Although improvement from baseline has been attributed to these patients receiving additional ICS therapy at pivotal times, electronic monitoring has not been used to test this hypothesis nor the equally plausible hypothesis that patients who are non-compliant with maintenance medication have used budesonide/formoterol as needed for self-treatment of exacerbations. Although the long-term consequences of SMART therapy have not been studied, its use over 1 year has been associated with significant increases in sputum and biopsy eosinophilia. At present, there is no evidence that better asthma treatment outcomes can be obtained by moment-to-moment symptom-driven use of ICS/LABA therapy than conventional physician-monitored and adjusted ICS/LABA therapy
    corecore