148 research outputs found

    Utility and lower limits of frequency detection in surface electrode stimulation for somatosensory brain-computer interface in humans

    Get PDF
    Objective: Stimulation of the primary somatosensory cortex (S1) has been successful in evoking artificial somatosensation in both humans and animals, but much is unknown about the optimal stimulation parameters needed to generate robust percepts of somatosensation. In this study, the authors investigated frequency as an adjustable stimulation parameter for artificial somatosensation in a closed-loop brain-computer interface (BCI) system. Methods: Three epilepsy patients with subdural mini-electrocorticography grids over the hand area of S1 were asked to compare the percepts elicited with different stimulation frequencies. Amplitude, pulse width, and duration were held constant across all trials. In each trial, subjects experienced 2 stimuli and reported which they thought was given at a higher stimulation frequency. Two paradigms were used: first, 50 versus 100 Hz to establish the utility of comparing frequencies, and then 2, 5, 10, 20, 50, or 100 Hz were pseudorandomly compared. Results: As the magnitude of the stimulation frequency was increased, subjects described percepts that were “more intense” or “faster.” Cumulatively, the participants achieved 98.0% accuracy when comparing stimulation at 50 and 100 Hz. In the second paradigm, the corresponding overall accuracy was 73.3%. If both tested frequencies were less than or equal to 10 Hz, accuracy was 41.7% and increased to 79.4% when one frequency was greater than 10 Hz (p = 0.01). When both stimulation frequencies were 20 Hz or less, accuracy was 40.7% compared with 91.7% when one frequency was greater than 20 Hz (p < 0.001). Accuracy was 85% in trials in which 50 Hz was the higher stimulation frequency. Therefore, the lower limit of detection occurred at 20 Hz, and accuracy decreased significantly when lower frequencies were tested. In trials testing 10 Hz versus 20 Hz, accuracy was 16.7% compared with 85.7% in trials testing 20 Hz versus 50 Hz (p < 0.05). Accuracy was greater than chance at frequency differences greater than or equal to 30 Hz. Conclusions: Frequencies greater than 20 Hz may be used as an adjustable parameter to elicit distinguishable percepts. These findings may be useful in informing the settings and the degrees of freedom achievable in future BCI systems

    Raman Scattering Study of Ba-doped C60 with t1g States

    Full text link
    Raman spectra are reported for Ba doped fullerides, BaxC60(x=3,4,and 6). The lowest frequency Hg modes split into five components for Ba4C60 and Ba6C60 even at room temperature, allowing us a quantitative analysis based on the electron-phonon couping theory. For the superconducting Ba4C60, the density of states at the Fermi energy was derived as 7 eV-1, while the total value of electron-phonon coupling \lambda was found to be 1.0, which is comparable to that of K3C60. The tangential Ag(2) mode, which is known as a sensitive probe for the degree of charge transfer on C60 molecule, shows a remarkable shift depending on the Ba concentration, being roughly consistent with the full charge transfer from Ba to C60. An effect of hybridization between Ba and C60 \pi orbitals is also discussed.Comment: 15 pages, 6 figures submitted to Phys. Rev. B (December 1,1998

    Utility and lower limits of frequency detection in surface electrode stimulation for somatosensory brain-computer interface in humans

    Get PDF
    Objective: Stimulation of the primary somatosensory cortex (S1) has been successful in evoking artificial somatosensation in both humans and animals, but much is unknown about the optimal stimulation parameters needed to generate robust percepts of somatosensation. In this study, the authors investigated frequency as an adjustable stimulation parameter for artificial somatosensation in a closed-loop brain-computer interface (BCI) system. Methods: Three epilepsy patients with subdural mini-electrocorticography grids over the hand area of S1 were asked to compare the percepts elicited with different stimulation frequencies. Amplitude, pulse width, and duration were held constant across all trials. In each trial, subjects experienced 2 stimuli and reported which they thought was given at a higher stimulation frequency. Two paradigms were used: first, 50 versus 100 Hz to establish the utility of comparing frequencies, and then 2, 5, 10, 20, 50, or 100 Hz were pseudorandomly compared. Results: As the magnitude of the stimulation frequency was increased, subjects described percepts that were “more intense” or “faster.” Cumulatively, the participants achieved 98.0% accuracy when comparing stimulation at 50 and 100 Hz. In the second paradigm, the corresponding overall accuracy was 73.3%. If both tested frequencies were less than or equal to 10 Hz, accuracy was 41.7% and increased to 79.4% when one frequency was greater than 10 Hz (p = 0.01). When both stimulation frequencies were 20 Hz or less, accuracy was 40.7% compared with 91.7% when one frequency was greater than 20 Hz (p < 0.001). Accuracy was 85% in trials in which 50 Hz was the higher stimulation frequency. Therefore, the lower limit of detection occurred at 20 Hz, and accuracy decreased significantly when lower frequencies were tested. In trials testing 10 Hz versus 20 Hz, accuracy was 16.7% compared with 85.7% in trials testing 20 Hz versus 50 Hz (p < 0.05). Accuracy was greater than chance at frequency differences greater than or equal to 30 Hz. Conclusions: Frequencies greater than 20 Hz may be used as an adjustable parameter to elicit distinguishable percepts. These findings may be useful in informing the settings and the degrees of freedom achievable in future BCI systems

    Ferromagnetism and giant magnetoresistance in the rare earth fullerides Eu6-xSrxC60

    Get PDF
    We have studied crystal structure, magnetism and electric transport properties of a europium fulleride Eu6C60 and its Sr-substituted compounds, Eu6-xSrxC60. They have a bcc structure, which is an isostructure of other M6C60 (M represents an alkali atom or an alkaline earth atom). Magnetic measurements revealed that magnetic moment is ascribed to the divalent europium atom with S = 7/2 spin, and a ferromagnetic transition was observed at TC = 10 - 14 K. In Eu6C60, we also confirm the ferromagnetic transition by heat capacity measurement. The striking feature in Eu6-xSrxC60} is very large negative magnetoresistance at low temperature; the resistivity ratio \rho(H = 9 T)/\rho(H = 0 T) reaches almost 10^{-3} at 1 K in Eu6C60. Such large magnetoresistance is the manifestation of a strong pi-f interaction between conduction carriers on C60 and 4f electrons of Eu.Comment: 5 pages, 4 figure

    Utilizing Light-field Imaging Technology in Neurosurgery

    Get PDF
    Traditional still cameras can only focus on a single plane for each image while rendering everything outside of that plane out of focus. However, new light-field imaging technology makes it possible to adjust the focus plane after an image has already been captured. This technology allows the viewer to interactively explore an image with objects and anatomy at varying depths and clearly focus on any feature of interest by selecting that location during post-capture viewing. These images with adjustable focus can serve as valuable educational tools for neurosurgical residents. We explore the utility of light-field cameras and review their strengths and limitations compared to other conventional types of imaging. The strength of light-field images is the adjustable focus, as opposed to the fixed-focus of traditional photography and video. A light-field image also is interactive by nature, as it requires the viewer to select the plane of focus and helps with visualizing the three-dimensional anatomy of an image. Limitations include the relatively low resolution of light-field images compared to traditional photography and video. Although light-field imaging is still in its infancy, there are several potential uses for the technology to complement traditional still photography and videography in neurosurgical education

    Utilizing Light-field Imaging Technology in Neurosurgery

    Get PDF
    Traditional still cameras can only focus on a single plane for each image while rendering everything outside of that plane out of focus. However, new light-field imaging technology makes it possible to adjust the focus plane after an image has already been captured. This technology allows the viewer to interactively explore an image with objects and anatomy at varying depths and clearly focus on any feature of interest by selecting that location during post-capture viewing. These images with adjustable focus can serve as valuable educational tools for neurosurgical residents. We explore the utility of light-field cameras and review their strengths and limitations compared to other conventional types of imaging. The strength of light-field images is the adjustable focus, as opposed to the fixed-focus of traditional photography and video. A light-field image also is interactive by nature, as it requires the viewer to select the plane of focus and helps with visualizing the three-dimensional anatomy of an image. Limitations include the relatively low resolution of light-field images compared to traditional photography and video. Although light-field imaging is still in its infancy, there are several potential uses for the technology to complement traditional still photography and videography in neurosurgical education

    Zinc intake, status and indices of cognitive function in adults and children: a systematic review and meta-analysis

    Get PDF
    In developing countries, deficiencies of micronutrients are thought to have a major impact on child development; however, a consensus on the specific relationship between dietary zinc intake and cognitive function remains elusive. The aim of this systematic review was to examine the relationship between zinc intake, status and indices of cognitive function in children and adults. A systematic literature search was conducted using EMBASE, MEDLINE and Cochrane Library databases from inception to March 2014. Included studies were those that supplied zinc as supplements or measured dietary zinc intake. A meta-analysis of the extracted data was performed where sufficient data were available. Of all of the potentially relevant papers, 18 studies met the inclusion criteria, 12 of which were randomised controlled trials (RCTs; 11 in children and 1 in adults) and 6 were observational studies (2 in children and 4 in adults). Nine of the 18 studies reported a positive association between zinc intake or status with one or more measure of cognitive function. Meta-analysis of data from the adult’s studies was not possible because of limited number of studies. A meta-analysis of data from the six RCTs conducted in children revealed that there was no significant overall effect of zinc intake on any indices of cognitive function: intelligence, standard mean difference of <0.001 (95% confidence interval (CI) –0.12, 0.13) P=0.95; executive function, standard mean difference of 0.08 (95% CI, –0.06, 022) P=0.26; and motor skills standard mean difference of 0.11 (95% CI –0.17, 0.39) P=0.43. Heterogeneity in the study designs was a major limitation, hence only a small number (n=6) of studies could be included in the meta-analyses. Meta-analysis failed to show a significant effect of zinc supplementation on cognitive functioning in children though, taken as a whole, there were some small indicators of improvement on aspects of executive function and motor development following supplementation but high-quality RCTs are necessary to investigate this further

    Effects of self-management, education and specific exercises, delivered by health professionals, in patients with osteoarthritis of the knee

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>An education self-management program for people with osteoarthritis (OA) of the knee was designed to be delivered by health professionals, incorporating their knowledge and expertise. Improvement in quality of life, health status and pain in response to this program has previously been demonstrated in an uncontrolled pilot study. To more rigorously test the effectiveness of the program we will undertake a randomised controlled trial of people with OA of the knee offering specific self-administered exercises and education, in accordance with the principles of self-management.</p> <p>Aim: To determine whether an education self management program for subjects with Osteoarthritis (OA) of the knee (OAK program) implemented by health professionals in a primary health care setting can achieve and maintain clinically meaningful improvements compared standard medical management in a control group.</p> <p>Methods</p> <p>The effects of standard medical management will be compared with the effects of the OAK program in a single-blind randomized study.</p> <p><it>Participants: </it>146 male and female participants with established OA knee will be recruited. Volunteers with coexistent inflammatory joint disease or serious co-morbidities will be excluded.</p> <p><it>Interventions: </it>Participants will be randomized into either intervention or control groups (delayed start). The intervention group will complete the OA knee program and both groups will be followed for 6 months.</p> <p><it>Measurements: </it>Assessments will be at baseline, 8 weeks and 6 months. SF-36, WOMAC and VAS pain questionnaires will be completed. Isometric quadriceps and hamstring strength will be measured using a dynamometer; knee range of movement using a goniometer; and physical function will be determined by a modified timed up and go test. Data will be analysed using repeated measures ANOVA.</p> <p>Discussion</p> <p>While there is evidence to support the effectiveness of SM programs for people with hypertension, diabetes and asthma, the evidence available for treatment of arthritis remains equivocal. The aim of this study is to determine the effectiveness of a disease specific self-management program for people with OA knee.</p> <p>The study design includes all the important features of a clinical experimental study to minimize bias so the results of the study will provide a high level of evidence. People with OA of the knee have identified pain and problems with daily activities as the most important problems associated with their condition. The outcome measures selected specifically address these issues and have demonstrated validity and are responsive within the range of change expected in response to the intervention. Hence the results of the study will reflect their priorities.</p> <p>The results of the study will provide evidence to guide clinicians and funding bodies seeking to establish priorities regarding the provision of this disease specific program.</p> <p>Trial registration</p> <p>ACTR number: 12607000080426</p

    Short and medium-term effects of an education self-management program for individuals with osteoarthritis of the knee, designed and delivered by health professionals: A quality assurance study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Self-management (SM) programs are effective for some chronic conditions, however the evidence for arthritis SM is inconclusive. The aim of this case series project was to determine whether a newly developed specific self-management program for people with osteoarthritis of the knee (OAK), implemented by health professionals could achieve and maintain clinically meaningful improvements.</p> <p>Methods</p> <p><it>Participants: </it>79 participants enrolled; mean age 66, with established osteoarthritis of the knee. People with coexisting inflammatory joint disease or serious co-morbidities were excluded.</p> <p><it>Intervention: </it>6-week disease (OA) and site (knee) specific self-management education program that included disease education, exercise advice, information on healthy lifestyle and relevant information within the constructs of self-management. This program was conducted in a community health care setting and was delivered by health professionals thereby utilising their knowledge and expertise.</p> <p><it>Measurements: </it>Pain, physical function and mental health scales were assessed at baseline, 8 weeks, 6 and 12 months using WOMAC and SF-36 questionnaires. Changes in pain during the 8-week intervention phase were monitored with VAS.</p> <p>Results</p> <p>Pain improved during the intervention phase: mean (95% CI) change 15 (8 to 22) mm. Improvements (0.3 to 0.5 standard deviation units) in indices of pain, mental health and physical functioning, assessed by SF-36 and WOMAC questionnaires were demonstrated from baseline to 12 months.</p> <p>Conclusion</p> <p>This disease and site-specific self-management education program improved health status of people with osteoarthritis of the knee in the short and medium term.</p
    corecore