    Calibration of the LIGO displacement actuators via laser frequency modulation

    Full text link
    We present a frequency modulation technique for calibration of the displacement actuators of the LIGO 4-km-long interferometric gravitational-wave detectors. With the interferometer locked in a single-arm configuration, we modulate the frequency of the laser light, creating an effective length variation that we calibrate by measuring the amplitude of the frequency modulation. By simultaneously driving the voice coil actuators that control the length of the arm cavity, we calibrate the voice coil actuation coefficient with an estimated 1-sigma uncertainty of less than one percent. This technique enables a force-free, single-step actuator calibration using a displacement fiducial that is fundamentally different from those employed in other calibration methods.Comment: 10 pages, 5 figures, submitted to Classical and Quantum Gravit

    Platelet kinetics in the pulmonary microcirculation in vivo assessed by intravital microscopy

    Get PDF
    Growing evidence supports the substantial pathophysiological impact of platelets on the development of acute lung injury. Methods for studying these cellular mechanisms in vivo are not present yet. The aim of this study was to develop a model enabling the quantitative analysis of platelet kinetics and platelet-endothelium interaction within consecutive segments of the pulmonary microcirculation in vivo. New Zealand White rabbits were anesthetized and ventilated. Autologous platelets were separated from blood and labeled ex vivo with rhodamine 6G. After implantation of a thoracic window, microhemodynamics and kinetics of platelets were investigated by intravital microscopy. Velocities of red blood cells (RBCs) and platelets were measured in arterioles, capillaries and venules, and the number of platelets adhering to the microvascular endothelium was counted. Kinetics of unstimulated platelets was compared with kinetics of thrombin-activated platelets. Velocity of unstimulated platelets was comparable to RBC velocity in all vessel segments. Unstimulated platelets passed the pulmonary microcirculation without substantial platelet-endothelial interaction. In contrast, velocity of activated platelets was decreased in all vascular segments indicating platelet margination and temporal platelet-endothelium interaction. Thrombin-activated platelets adhered to arteriolar endothelium; in capillaries and venules adherence of platelets was increased 8-fold and 13-fold, respectively. In conclusion, using intravital microscopy platelet kinetics were directly analyzed in the pulmonary microcirculation in vivo for the first time. In contrast to leukocytes, no substantial platelet-endothelium interaction occurs in the pulmonary microcirculation without any further stimulus. In response to platelet activation, molecular mechanisms enable adhesion of platelets in arterioles and venules as well as retention of platelets within capillaries. Copyright (C) 2002 S. Karger AG, Basel

    Leukocyte margination in alveolar capillaries: Interrelationship with functional capillary geometry and microhemodynamics

    Get PDF
    The pulmonary capillary microvasculature harbors a large pool of intravascularly marginated leukocytes. In this study, we investigated the interrelationship of leukocyte margination with characteristics of functional capillary geometry and microhemodynamics in alveolar capillary networks. In 22 anesthetized rabbits we assessed functional capillary density, average capillary length, red blood cell velocity and leukocyte kinetics in alveolar capillary networks in vivo by intravital fluorescence microscopy. In alveolar wall areas of 12,800 +/- 1,800 mu m(2), we detected 3.6 +/- 0.5 sticking leukocytes and 21.0 +/- 1.9 functional capillary segments with an average capillary length of 35.7 +/- 2.1 mu m. We calculated that approximately 15% of functional capillary segments are blocked by marginated leukocytes. Leukocyte margination was predominantly observed in capillary networks characterized by a high functional capillary density, short capillary segments and low red blood cell velocities. The multitude of interconnected capillary channels in these networks may allow alveolar blood flow to bypass marginated leukocytes. Hence, this interrelationship may be relevant for maintenance of adequate alveolar perfusion and low capillary network resistance despite excessive leukocyte margination in the pulmonary microvasculature. Local microhemodynamic factors may play a regulatory role in the spatial distribution of leukocyte margination

    Dynamic evolution of the source volumes of gradual and impulsive solar flare emissions

    Get PDF
    This study compares flare source volumes inferred from impulsive hard X-rays and microwaves with those derived from density sensitive soft X-ray line ratios in the O VII spectrum. The data for this study were obtained with the SMM Hard X-Ray Burst Spectrometer, Earth-based radio observatories, and the SOLEX-B spectrometer on the P78-1 satellite. Data were available for the flares of 1980 April 8, 1980 May 9, and 1981 February 26. The hard X-ray/microwave source volume is determined under the assumption that the same electron temperature or power law index characterizes both the source of hard X-rays and the source of microwaves. The O VII line ratios yield the density and volume of the 2 X 10 to the 6th K plasma. For all three flares, the O VII source volume is found to be smallest at the beginning of the flare, near the time when the impulsive hard X-ray/microwave volume reaches its first maximum. At this time, the O VII volume is three to four orders of magnitude smaller than that inferred from the hard X-ray/microwave analysis. Subsequently, the O VII source volume increases by one or two orders of magnitude then remains almost constant until the end of the flare when it apparently increases again

    Leukocyte sequestration in pulmonary microvessels and lung injury following systemic complement activation in rabbits

    Get PDF
    Inflammatory reactions are associated with sequestration of leukocytes in the lung. Complement activation leads to accumulation of leukocytes in alveolar septa and alveoli, to lung edema and hemorrhage. Although in organs other than the lung leukocytes interact with the vascular endothelium only in postcapillary venules, alveolar capillaries are considered to be the site of leukocyte sequestration in the lung. However, pulmonary venules and arterioles have not been investigated systematically after complement activation so far, A closed thoracic window was implanted in anesthetized rabbits; leukocytes and red blood cells were stained, and the movement of these cells was measured in superficial pulmonary arterioles, venules and alveolar capillaries using fluorescence video microscopy before and 30 and 60 min after infusion of cobra venom factor (CVF). Erythrocyte velocity and macrohemodynamic conditions did not change after CVF infusion and were not different from the sham-treated controls. The number of sticking leukocytes increased significantly compared to baseline and control: by 150% in arterioles and in venules and by 740% in alveolar capillaries within 60 min after CVF infusion. The width of alveolar septa in vivo was significantly enlarged after CVF infusion, indicating interstitial pulmonary edema. At the end of the experiments, myeloperoxidase activity was higher in the CVF group, showing leukocyte sequestration in the whole organ. It is concluded that complement activation by CVF induces leukocyte sequestration in lung arterioles, venules and alveolar capillaries and leads to mild lung injury

    Modular Multilevel Converter with Sensorless Diode-Clamped Balancing through Level-Adjusted Phase-Shifted Modulation

    Full text link
    Cascaded H-bridge and modular multilevel converters (MMC) are on the rise with emerging applications in renewable energy generation, energy storage, and electric motor drives. However, their well-known advantages come at the price of complicated balancing, high-bandwidth isolated monitoring, and numerous sensors that can prevent MMCs from expanding into highly cost driven markets. Therefore, an obvious trend in research is developing control and topologies that depend less on measurements and benefit from simpler control. Diode-clamped topologies are considered among the more applicable solutions. The main problem with a diode-clamped topology is that it can only balance the module voltages of a string in one direction; therefore, it cannot provide a completely balanced operation. This paper proposes an effective balancing technique for the diode-clamped topology. The proposed solution exploits the dc component of the arm current by introducing a symmetrically level-adjusted phase-shifted modulation scheme, and ensures the balancing current flow is always in the correct direction. The main advantages of this method are sensorless operation, no added computation and control effort, and low overall cost. Analysis and detailed simulations provide insight into the operation of the system as well as the new balancing technique and the experimental results confirm the provided discussions

    Geologic applications of ERTS images on the Colorado Plateau, Arizona

    Get PDF
    Three areas in central and northern Arizona centered on the (1) Verde Valley, (2) Coconino Plateau, and (3) Shivwits Plateau were studied using ERTS photography. Useful applications results include: (1) upgrading of the existing state geologic map of the Verde Valley region; (2) detection of long NW trending lineaments in the basalt cap SE of Flagstaff which may be favorable locations for drilling for new water supplies; (3) tracing of the Bright Angel and Butte faults to twice their previously known length and correlating the extensions with modern seismic events, showing these faults to be present-day earthquake hazards; (4) discovering and successfully drilling perched sandstone aquifers in the Kaibab Limestone on the Coconino Plateau; and (5) determining the relationship between the Shivwits lavas and the formation of the lower Grand Canyon and showing that the lavas should be an excellent aquifer, as yet untapped
    • …