153 research outputs found
Recommended from our members
Overcoming intrinsic spin resonance by using an AC dipole
Depolarization from an intrinsic spin resonance can be avoided by adiabatically exciting a coherent betatron oscillation. Sustained coherent transverse beam oscillations have been achieved in the AGS using a high frequency AC driven dipole magnet. The amplitude of the oscillations using the present system has been as large as 2.6 times the rms beam size, and the oscillations were held at this level for over 1,000 revolutions. By adiabatically increasing and decreasing the dipole field amplitude during this procedure, the transverse emittance of the beam was left unaffected. To set the scale, had an oscillation of that amplitude been left to oscillate freely, the beam emittance would have increased by a factor of 7 after filamentation. This result provides encouragement that this technique can be used to induce spin flip of polarized proton beams in synchrotrons when crossing strong intrinsic depolarizing resonances during acceleration. Another application of this device in a polarized beams storage ring would be the reversal of the polarized beams storage ring would be the reversal of the polarization direction of the beam. By slowly sweeping the frequency of the modulated dipole field through the spin precession frequency of the storage ring, an adiabatic spin flip can be induced, thus reversing the polarization direction of each individual particle in the storage ring without increasing the beam emittance. This can be useful for reducing systematic errors in polarized beam experiments
Recommended from our members
Mini-bunching the AGS slow external beam
Test and modeling toward providing a continuous string of proton bursts of a few nano-seconds every 3 to 10 micro-seconds for the two second BNL AGS spill are presented
Recommended from our members
Micro-bunching the AGS slow external beam
Measurements and modeling are presented on BNL`s AGS operation of the slow External Beam with subnanosecond beam bunching for the full two second spill
Recommended from our members
A multi-wire beam profile monitor in the AGS
A multi-wire beam profile monitor which can be used to directly monitor and control the optical matching between the Booster and AGS rings has been installed and tested in the AGS. Placement of a multi-wire monitor directly in the AGS provides profile measurements taken upon injection and the first two or more revolutions of the beam. The data from such measurements can be used to determine the optical properties of the beam transport line leading into the AGS
Hyperfine Magnetic Field Measurement in Heusler Alloys by TDPAC Technique
This work was supported by National Science Foundation Grants PHY 76-84033A01, PHY 78-22774, and Indiana Universit
Combining Cardiac Monitoring with Actigraphy Aids Nocturnal Arousal Detection during Ambulatory Sleep Assessment in Insomnia
Study Objectives: The objective assessment of insomnia has remained difficult. Multisensory devices collecting heart rate (HR) and motion are regarded as the future of ambulatory sleep monitoring. Unfortunately, reports on altered average HR or heart rate variability (HRV) during sleep in insomnia are equivocal. Here, we evaluated whether the objective quantification of insomnia improves by assessing state-related changes in cardiac measures. Methods: We recorded electrocardiography, posture, and actigraphy in 33 people without sleep complaints and 158 patients with mild to severe insomnia over 4 d in their home environment. At the microscale, we investigated whether HR changed with proximity to gross (body) and small (wrist) movements at nighttime. At the macroscale, we calculated day-night differences in HR and HRV measures. For both timescales, we tested whether outcome measures were related to insomnia diagnosis and severity. Results: At the microscale, an increase in HR was often detectable already 60 s prior to as well as following a nocturnal chest, but not wrist, movement. This increase was slightly steeper in insomnia and was associated with insomnia severity, but future EEG recordings are necessary to elucidate whether these changes occur prior to or simultaneously with PSG-indicators of wakefulness. At the macroscale, we found an attenuated cardiac response to sleep in insomnia: patients consistently showed smaller day-night differences in HR and HRV. Conclusions: Incorporating state-related changes in cardiac features in the ambulatory monitoring of sleep might provide a more sensitive biomarker of insomnia than the use of cardiac activity averages or actigraphy alone
Recommended from our members
AGS tune jump system to cross horizontal depolarization resonances overview
Two partial snakes overcome the vertical depolarizing resonances in the AGS. But a new type of depolarizing intrinsic resonance from horizontal motion appeared. We reduce these using horizontal tune jumps timed to these resonances. We gain a factor of six in crossing rate with a tune jump of 0.05 in 100 {micro}s. Two quadrapoles, we described in 2009, pulse 42 times, the current matching beam energy. The power supplies for these quads are described in detail elsewhere in this conference. The controls for the Jump Quad system is based on a BNL designed Quad Function Generator. Two modules are used; one for timing, and one to supply reference voltages. Synchronization is provided by a proprietary serial bus, the Event Link. The AgsTuneJump application predicts the times of the resonances during the AGS cycle and calculates the power supply trigger times from externally collected tune and energy versus time data and the Low and High PS voltage functions from a voltage to current model of the power supply. The system was commissioned during runs 09 & 10 and is operational. Many beam effects are described elsewhere. The TuneJump system has worked well and has caused little trouble save for the perturbations in the lattice having such a large effect due to our need to run with the vertical tune within a few thousandths of the integer tune. As these problems were mostly sorted out by correcting the 6th harmonic orbit distortions which caused a large 18 theta beta wave. Also running with minimal chromaticity reduces emittance growth. There are still small beta waves which are being addressed. The timing of the pulses is still being investigated, but as each crossing causes minimal polarization loss, this is a lengthy process
Recommended from our members
AGS tune jump power supply design and test
A horizontal tune jump system has been installed to overcome the horizontal intrinsic spin resonances, which requires jumping the horizontal tune 0.04 units 82 times, 41 up and 41 down. Two quadruple magnets have been installed in AGS ring to perform this. The pulsed magnet current ranges from about 140A near injection to about 1400A later. The current pulse rise and fall time are around 100uS and flat tops time is around 4mS. These quadruples have separated supplies. This tune jump pulse power supply employees all semiconductor parts as well as the main switches. During dummy load and magnet testing, the test results showed that the power supply could meet the specification. This article will describe some details of power supply simulation, design and testing. Some test waveforms and pictures are presented in this paper
A Clinical Tool to Identify Candidates for Stress-First Myocardial Perfusion Imaging
Objectives: This study sought to develop a clinical model that identifies a lower-risk population for coronary artery disease that could benefit from stress-first myocardial perfusion imaging (MPI) protocols and that can be used at point of care to risk stratify patients. Background: There is an increasing interest in stress-first and stress-only imaging to reduce patient radiation exposure and improve patient workflow and experience. Methods: A secondary analysis was conducted on a single-center cohort of patients undergoing single-photon emission computed tomography (SPECT) and positron emission tomography (PET) studies. Normal MPI was defined by the absence of perfusion abnormalities and other ischemic markers and the presence of normal left ventricular wall motion and left ventricular ejection fraction. A model was derived using a cohort of 18,389 consecutive patients who underwent SPECT and was validated in a separate cohort of patients who underwent SPECT (n = 5,819), 1 internal cohort of patients who underwent PET (n=4,631), and 1 external PET cohort (n = 7,028). Results: Final models were made for men and women and consisted of 9 variables including age, smoking, hypertension, diabetes, dyslipidemia, typical angina, prior percutaneous coronary intervention, prior coronary artery bypass graft, and prior myocardial infarction. Patients with a score ≤1 were stratified as low risk. The model was robust with areas under the curve of 0.684 (95% confidence interval [CI]: 0.674 to 0.694) and 0.681 (95% CI: 0.666 to 0.696) in the derivation cohort, 0.745 (95% CI: 0.728 to 0.762) and 0.701 (95% CI: 0.673 to 0.728) in the SPECT validation cohort, 0.672 (95% CI: 0.649 to 0.696) and 0.686 (95% CI: 0.663 to 0.710) in the internal PET validation cohort, and 0.756 (95% CI: 0.740 to 0.772) and 0.737 (95% CI: 0.716 to 0.757) in the external PET validation cohort in men and women, respectively. Men and women who scored ≤1 had negative likelihood ratios of 0.48 and 0.52, respectively. Conclusions: A novel model, based on easily obtained clinical variables, is proposed to identify patients with low probability of having abnormal MPI results. This point-of-care tool may be used to identify a population that might qualify for stress-first MPI protocols
- …