20 research outputs found

    Concordance between macrophytes and macroinvertebrates in a Mediterranean river of central Apennine region.

    No full text
    The main aim of this study was to improve the knowledge about the concordance among macrophytes and macroinvertebrates to provide complementary information and facilitate the procedures for quality assessment of river ecosystems. Macrophytes and macroinvertebrates were collected in 11 sampling sites along a central Apennine calcareous river in October 2008 and June 2009. The concordance between the two biomonitoring groups was tested according to several environmental parameters. The comparison of the data matrix similarities by the Mantel test showed differences in the assemblage of macrophytes and macroinvertebrates along the river since correlation values were 0.04, p>0.05 in October 2008 and 0.39, p>0.05 in June 2009. The study revealed a lack of concordance between the two groups emphasizing the information provided by macrophytes and macroinvertebrates does not overlap in terms of response to environmental parameters. Indeed, the two different biological groups resulted useful descriptors of different parameters. Together, they could represent a complementary tool to reflect the river environmental quality

    [Magnetic resonance pyelography: optimization of the technic and the preliminary results].

    No full text
    Magnetic resonance pyelography (MRP) is a new noninvasive method which demonstrates dilated urinary tracts with no need of contrast agent injection. This study was aimed at technique optimization, using new fast sequences with high intrinsic contrast, to demonstrate the urinary tract in obstructive uropathy patients. Twelve consecutive patients and 4 healthy volunteers were included in this prospective study; all the exams were performed with a high gradient power 0.5-T unit using T2- weighted turbo SE sequences, acquired three-dimensionally on the coronal plane. Obstructive uropathy was caused in 9 patients by neoplastic lesions, in 2 by postoperative strictures and in 1 by inflammatory tissue. In all patients MRP depicted the dilated urinary tract optimally, with good morphological detailing and the accurate assessment of both level and cause of obstruction. In the healthy volunteers, the absence of dilatation did not permit the complete visualization of the urinary tract. To conclude, MRP is a new technique which permits high-quality imaging of the urinary tract. Further studies are needed to assess its actual potentials and clinical role

    [Assessment of renal function using low doses of paramagnetic contrast media].

    No full text
    Dynamic MR techniques with Gd-DTPA bolus administration can be used to study renal perfusion and function. In previous studies, the concentration of Gd-DTPA injected was never lower than 0.1 mmol/kg: as a result, depending on the magnetic susceptibility effect, renal signal intensity reduced in the early phases, right after contrast agent injection. To prevent signal intensity from reducing in the early phases, in our study we used a concentration of 0.05 mmol/kg. Qualitative and quantitative evaluations were performed. Seven healthy subjects and 14 patients with different degrees of renal insufficiency were enrolled in the study. All exams were performed using an 0.5-T magnet (Philips Gyroscan T5, II), with 15 mT/m gradient power. Signal intensity measurements at the cortical, external medullary and internal medullary levels, allowed the drawing of curves typical of each degree of renal insufficiency which correlated well with nuclear medicine (scintigraphy) findings. The qualitative evaluation provided results comparable with scintigraphic findings in all 7 normal subjects, in 3 of 4 cases of moderate renal insufficiency, in all 7 cases of moderate/severe renal insufficiency and in the only case of severe renal insufficiency. To conclude, this trial demonstrates the feasibility of MR studies of renal function, which provide morphological and functional pieces of information. Low concentration Gd-DTPA is decisive to avoid the magnetic susceptibility artifacts observed in previous studies

    Impianto uretrale di collagene nel trattamento dell’incontinenza urinaria: confronto tra accesso transuretrale e periuretrale

    No full text
    corecore