525 research outputs found

    Analysis of transferred fragrance and its forensic implications

    Get PDF
    Perfumes are widely used by many people in developed countries, and a large number of both men and women wear perfumes on a daily basis. Analysis of perfume trace materials from clothing is not commonly employed within forensic casework, yet as a form of trace evidence it has the potential to provide valuable intelligence. In order to appreciate the value of trace evidence there is a fundamental need for an evidence base that can both offer insight into how a trace material behaves under different scenarios and activities, and from which inferences can be made. With this purpose a gas chromatography-mass spectrometry method for trace analysis of perfumes was developed. This paper presents two different series of experiments that investigate the dynamics of perfume transfer as a factor of perfume ageing time, and as a factor of perfume contact time. Empirical data showed that both perfume ageing time, and perfume contact time play a key role in the number of perfume components transferred. These studies have implication for forensic protocols, specifically for perfume trace evidence collection, analysis, interpretation, and presentation, and there is potentially great value in analysing perfumes from clothing exhibits in forensic enquiries that involve close contact between individuals, such as sexual assaults

    Persistence of transferred fragrance on fabrics for forensic reconstruction applications

    Get PDF
    It has recently been established that volatile organic compounds (VOCs) successfully transfer between clothing even with a short contact of 10 s, highlighting the potential to use VOCs in forensic reconstruction scenarios, such as sexual assault cases. The mid and low volatility compounds transferred in greater amounts than high volatility compounds. This study presents empirical data addressing the persistence of transferred VOCs on clothing for the first time. A series of experiments were carried out to determine the persistence of VOCs on clothing for time periods of up 4 weeks, on natural and synthetic fibres, and at three different environmental temperatures. The data indicate that the highest VOC amounts are generally obtained for shorter persistence times of up to 1 d. Whilst high volatility compounds were not recovered in sufficient amounts to allow quantification, the four other transferred VOCs were successfully quantified for persistence times of up to 4 weeks. The persistence for mid-volatility compounds follows decay curve trends in line with those previously obtained for fibres, glass and pollen. When comparing the persistence of VOCs on a natural and a synthetic fibre, for a persistence time of 1 h, the transferred VOCs were retained on a natural fibre in higher amounts than on a synthetic fibre. However, for longer persistence times the concentration of VOCs was similar between the two fabrics. Lastly, lower environmental temperatures resulted in higher recoveries for most VOCs, especially for short persistence times. These findings demonstrate that optimal recovery of VOCs from clothing occurs when the fabric is kept at cooler temperatures and analysed soon after the fragrance transfer occurred, although VOC recovery was possible at higher temperatures and after longer persistence times. Given the transfer and persistence characteristics of VOCs from fragrance, there is potential for fragrance to be used as a form of trace in forensic reconstruction approaches

    Retinal Microvascular Dysfunction Occurs Early and Similarly in Mild Alzheimer’s Disease and Primary-Open Angle Glaucoma Patients

    Get PDF
    Purpose: To assess the similarities and differences in retinal microvascular function between mild Alzheimer’s disease (AD) patients, early-stage primary open angle glaucoma (POAG) patients and healthy controls. Methods: Retinal vessel reactivity to flickering light was assessed in 10 AD, 19 POAG and 20 healthy age matched control patients by means of dynamic retinal vessel analysis (DVA, IMEDOS, GmbH, Jena, Germany) according to an established protocol. All patients additionally underwent BP measurements and blood analysis for glucose and lipid metabolism markers. Results: AD and POAG patients demonstrated comparable alterations in retinal artery reactivity, in the form of an increased arterial reaction time (RT) to flicker light on the final flicker cycle (p = 0.009), which was not replicated by healthy controls (p > 0.05). Furthermore, the sequential changes in RT on progressing from flicker one to flicker three were found to differ between healthy controls and the two disease groups (p = 0.001). Conclusion: AD and POAG patients demonstrate comparable signs of vascular dysfunction in their retinal arteries at the early stages of their disease process. This provides support for the concept of a common underlying vascular aetiology in these two neurodegenerative diseases

    Impact of Bariatric Surgery-Induced Weight Loss on Anterior Eye Health in Patients with Obesity

    Get PDF
    The aim of the present research was to assess the effect of bariatric surgery-induced weight loss on the tear film and ocular surface of patients with obesity. A total of 29 participants with obesity (aged 47.2 10.1 years, 8 male) were measured at baseline and followed up one year after Roux-en-Y gastric bypass (RYGB) surgery. General anthropometric data, as well as serum lipid markers of cholesterol, were assessed in all individuals. Bilateral anterior eye measurements of tear meniscus height (TMH), non-invasive tear breakup time, bulbar and limbal redness and infrared meibography were captured using the Keratograph K5M (Oculus) and ocular surface damage was evaluated using fluorescein sodium and lissamine green staining. Bariatric surgery resulted in significant loss of weight (body mass index p 0.05). Although there were trends for a reduced TMH and a decrease in meibomian gland dropout after bariatric surgery, these differences were also insignificant (p > 0.05). In conclusion, weight reduction through bariatric surgery did not have an effect on the tear film or ocular surface in unselected patients with obesity

    Development of a HS-SPME/GC-MS method for the analysis of volatile organic compounds from fabrics for forensic reconstruction applications.

    Get PDF
    An analytical method for the determination of trace amounts of volatile organic compounds (VOCs) relevant to the cosmetics industry was optimised, validated and employed for the analysis of commercial perfumes. The method used a combination of headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS). In addition to fibre type, three different HS-SPME extraction conditions were investigated simultaneously, namely incubation time, extraction time and extraction temperature, using a central composite design in order to determine the optimal conditions for the extraction of VOCs of interest. The main figures of merit of the proposed method (calibration range, limits of detection and quantification, trueness and precision) were evaluated for six different VOCs in both natural and synthetic fibres in order to validate it and verify its capability for the proposed application. The validated method was applied for the analysis of traces of commercial perfumes from fabrics, and the VOCs of interest were successfully quantified. This simple, highly sensitive, and robust method has the potential to represent a powerful approach for forensic reconstructions where perfumes have transferred between individuals, such as during assaults and sexual assaults

    KASCADE-Grande Limits on the Isotropic Diffuse Gamma-Ray Flux between 100 TeV and 1 EeV

    Get PDF
    KASCADE and KASCADE-Grande were multi-detector installations to measure individual air showers of cosmic rays at ultra-high energy. Based on data sets measured by KASCADE and KASCADE-Grande, 90% C.L. upper limits to the flux of gamma-rays in the primary cosmic ray flux are determined in an energy range of 10141018{10}^{14} - {10}^{18} eV. The analysis is performed by selecting air showers with a low muon content as expected for gamma-ray-induced showers compared to air showers induced by energetic nuclei. The best upper limit of the fraction of gamma-rays to the total cosmic ray flux is obtained at 3.7×10153.7 \times {10}^{15} eV with 1.1×1051.1 \times {10}^{-5}. Translated to an absolute gamma-ray flux this sets constraints on some fundamental astrophysical models, such as the distance of sources for at least one of the IceCube neutrino excess models.Comment: Published in The Astrophysical Journal, Volume 848, Number 1. Posted on: October 5, 201

    KCDC - The KASCADE Cosmic-ray Data Centre

    Get PDF
    KCDC, the KASCADE Cosmic-ray Data Centre, is a web portal, where data of astroparticle physics experiments will be made available for the interested public. The KASCADE experiment, financed by public money, was a large-area detector for the measurement of high-energy cosmic rays via the detection of air showers. KASCADE and its extension KASCADE-Grande stopped finally the active data acquisition of all its components including the radio EAS experiment LOPES end of 2012 after more than 20 years of data taking. In a first release, with KCDC we provide to the public the measured and reconstructed parameters of more than 160 million air showers. In addition, KCDC provides the conceptional design, how the data can be treated and processed so that they are also usable outside the community of experts in the research field. Detailed educational examples make a use also possible for high-school students and early stage researchers.Comment: 8 pages, accepted proceeding of the ECRS-symposium, Kiel, 201
    corecore