64 research outputs found
Achieving diffraction-limited resolution in soft-X-ray Fourier-transform holography
The spatial resolution of microscopic images acquired via X-ray Fourier-transform holography is limited by the source size of the reference wave and by the numerical aperture of the detector. We analyze the interplay between both influences and show how they are matched in practice. We further identify, how high spatial frequencies translate to imaging artifacts in holographic reconstructions where mainly the reference beam limits the spatial resolution. As a solution, three methods are introduced based on numerical post-processing of the reconstruction. The methods comprise apodization of the hologram, refocusing via wave propagation, and deconvolution using the transfer function of the imaging system. In particular for the latter two, we demonstrate that image details smaller than the source size of the reference beam can be recovered up to the diffraction limit of the hologram. Our findings motivate the intentional application of a large reference-wave source enhancing the image contrast in applications with low photon numbers such as single-shot experiments at free-electron lasers or imaging at laboratory sources.BMBF, 05K10KTB, Verbundprojekt: FSP 301 - FLASH: Nanoskopische Systeme. Teilprojekt 1.1: Universelle Experimentierkammer für Streuexperimente mit kohärenten Femtosekunden-Röntgenpulsen Multi Purpose Coherent Scattering Chamber for FLASH and XFEL 'MPscatt
Online Search Tool for Graphical Patterns in Electronic Band Structures
We present an online graphical pattern search tool for electronic band
structure data contained within the Organic Materials Database (OMDB) available
at https://omdb.diracmaterials.org/search/pattern. The tool is capable of
finding user-specified graphical patterns in the collection of thousands of
band structures from high-throughput ab initio calculations in the online
regime. Using this tool, it only takes a few seconds to find an arbitrary
graphical pattern within the ten electronic bands near the Fermi level for
26,739 organic crystals. The tool can be used to find realizations of
functional materials characterized by a specific pattern in their electronic
structure, for example, Dirac materials, characterized by a linear crossing of
bands; topological insulators, characterized by a "Mexican hat" pattern or an
effectively free electron gas, characterized by a parabolic dispersion. The
source code of the developed tool is freely available at
https://github.com/OrganicMaterialsDatabase/EBS-search and can be transferred
to any other electronic band structure database. The approach allows for an
automatic online analysis of a large collection of band structures where the
amount of data makes its manual inspection impracticable.Comment: 8 pages, 8 figure
Experimental evaluation of signal-to-noise in spectro-holography via modified uniformly redundant arrays in the soft x-ray and extreme ultraviolet spectral regime
We present dichroic x-ray lensless magnetic imaging by Fourier transform holography with an extended reference scheme via a modified uniformly redundant array (mURA). Holographic images of magnetic domains simultaneously generated by a single pinhole reference as well as by a mURA reference are compared with respect to the signal-to-noise ratio (SNR) as a function of exposure time. We apply this approach for spectro-holographic imaging of ferromagnetic domain patterns in Co/Pt multilayer films. Soft x-rays with wavelengths of 1.59 nm (Co L 3 absorption edge) and 20.8 nm (Co M 2,3 absorption edges) are used for image formation and to generate contrast via x-ray magnetic circular dichroism. For a given exposure time, the mURA-based holography allows to decouple the reconstruction SNR from the spatial resolution. For 1.59 nm wavelength, the reconstruction via the extended reference scheme shows no significant loss of spatial resolution compared to the single pinhole reference. In contrast, at 20.8 nm wavelength the single pinhole reveals some very intricate features which are lost in the image generated by the mURA, although overall a high-quality image is generated. The SNR-advantage of the mURA scheme is most notable when the hologram has to be encoded with few photons, while errors associated with the increased complexity of the reconstruction process reduce the advantage for high-photon-number experiments.BMBF, 05K13KT3, Verbundprojekt 05K2013 - DynaMaX: Messplatz für ultraschnelle Dynamik bei BESSY II. Teilprojekt
Exchange interaction and its tuning in magnetic binary chalcogenides
Using a first-principles Green's function approach we study magnetic
properties of the magnetic binary chalcogenides Bi2Te3, Bi2Se3, and Sb2Te3. The
magnetic coupling between transition-metal impurities is long-range, extends
beyond a quintuple layer, and decreases with increasing number of d electrons
per 3d atom. We find two main mechanisms for the magnetic interaction in these
materials: the indirect exchange interaction mediated by free carriers and the
indirect interaction between magnetic moments via chalcogen atoms. The
calculated Curie temperatures of these systems are in good agreement with
available experimental data. Our results provide deep insight into magnetic
interactions in magnetic binary chalcogenides and open a way to design new
materials for promising applications
Monolithic focused reference beam x-ray holography
Fourier transform holography is a highly efficient and robust imaging method, suitable for single-shot imaging at coherent X-ray sources. In its common implementation, the image contrast is limited by the reference signal generated by a small pinhole aperture. Increased pinhole diameters improve the signal, whereas the resolution is diminished. Here we report a new concept to decouple the spatial resolution from the image contrast by employing a Fresnel zone plate to provide the reference beam. Superimposed on-axis images of distinct foci are separated with a novel algorithm. Our method is insensitive to mechanical drift or vibrations and allows for long integration times common at low-flux facilities like high harmonic generation sources. The application of monolithic focused reference beams improves the efficiency of high-resolution X-ray Fourier transform holography beyond all present approaches and paves the path towards sub-10 nm single-shot X-ray imaging
Recommended from our members
Experimental evaluation of signal-to-noise in spectro-holography via modified uniformly redundant arrays in the soft x-ray and extreme ultraviolet spectral regime
We present dichroic x-ray lensless magnetic imaging by Fourier transform holography with an extended reference scheme via a modified uniformly redundant array (mURA). Holographic images of magnetic domains simultaneously generated by a single pinhole reference as well as by a mURA reference are compared with respect to the signal-to-noise ratio (SNR) as a function of exposure time. We apply this approach for spectro-holographic imaging of ferromagnetic domain patterns in Co/Pt multilayer films. Soft x-rays with wavelengths of 1.59 nm (Co L3 absorption edge) and 20.8 nm (Co M2,3 absorption edges) are used for image formation and to generate contrast via x-ray magnetic circular dichroism. For a given exposure time, the mURA-based holography allows to decouple the reconstruction SNR from the spatial resolution. For 1.59 nm wavelength, the reconstruction via the extended reference scheme shows no significant loss of spatial resolution compared to the single pinhole reference. In contrast, at 20.8 nm wavelength the single pinhole reveals some very intricate features which are lost in the image generated by the mURA, although overall a high-quality image is generated. The SNR-advantage of the mURA scheme is most notable when the hologram has to be encoded with few photons, while errors associated with the increased complexity of the reconstruction process reduce the advantage for high-photon-number experiments
Irreversible transformation of ferromagnetic ordered stripe domains in single-shot IR pump - resonant X-ray scattering probe experiments
The evolution of a magnetic domain structure upon excitation by an intense,
femtosecond Infra-Red (IR) laser pulse has been investigated using single-shot
based time-resolved resonant X-ray scattering at the X-ray Free Electron laser
LCLS. A well-ordered stripe domain pattern as present in a thin CoPd alloy film
has been used as prototype magnetic domain structure for this study. The
fluence of the IR laser pump pulse was sufficient to lead to an almost complete
quenching of the magnetization within the ultrafast demagnetization process
taking place within the first few hundreds of femtoseconds following the IR
laser pump pulse excitation. On longer time scales this excitation gave rise to
subsequent irreversible transformations of the magnetic domain structure. Under
our specific experimental conditions, it took about 2 nanoseconds before the
magnetization started to recover. After about 5 nanoseconds the previously
ordered stripe domain structure had evolved into a disordered labyrinth domain
structure. Surprisingly, we observe after about 7 nanoseconds the occurrence of
a partially ordered stripe domain structure reoriented into a novel direction.
It is this domain structure in which the sample's magnetization stabilizes as
revealed by scattering patterns recorded long after the initial pump-probe
cycle. Using micro-magnetic simulations we can explain this observation based
on changes of the magnetic anisotropy going along with heat dissipation in the
film.Comment: 16 pages, 6 figure
- …