232 research outputs found

    Short-term and long-term outcomes of a disruption and disconnection of the pancreatic duct in necrotizing pancreatitis: a multicenter cohort study in 896 patients

    Get PDF
    INTRODUCTION: Necrotizing pancreatitis may result in a disrupted or disconnected pancreatic duct (DPD) with the potential for long-lasting negative impact on a patient's clinical outcome. There is a lack of detailed data on the full clinical spectrum of DPD, which is critical for the development of better diagnostic and treatment strategies. METHODS: We performed a long-term post hoc analysis of a prospectively collected nationwide cohort of 896 patients with necrotizing pancreatitis (2005-2015). The median follow-up after hospital admission was 75 months (P25-P75: 41-151). Clinical outcomes of patients with and without DPD were compared using regression analyses, adjusted for potential confounders. Predictive features for DPD were explored. RESULTS:  DPD was confirmed in 243 (27%) of the 896 patients and resulted in worse clinical outcomes during both the patient's initial admission and follow-up. During hospital admission, DPD was associated with an increased rate of new-onset intensive care unit admission (adjusted odds ratio [aOR] 2.52; 95% confidence interval [CI] 1.62-3.93), new-onset organ failure (aOR 2.26; 95% CI 1.45-3.55), infected necrosis (aOR 4.63; 95% CI 2.87-7.64), and pancreatic interventions (aOR 7.55; 95% CI 4.23-13.96). During long-term follow-up, DPD increased the risk of pancreatic intervention (aOR 9.71; 95% CI 5.37-18.30), recurrent pancreatitis (aOR 2.08; 95% CI 1.32-3.29), chronic pancreatitis (aOR 2.73; 95% CI 1.47-5.15), and endocrine pancreatic insufficiency (aOR 1.63; 95% CI 1.05-2.53). Central or subtotal pancreatic necrosis on computed tomography (OR 9.49; 95% CI 6.31-14.29) and a high level of serum C-reactive protein in the first 48 hours after admission (per 10-point increase, OR 1.02; 95% CI 1.00-1.03) were identified as independent predictors for developing DPD. DISCUSSION:  At least 1 of every 4 patients with necrotizing pancreatitis experience DPD, which is associated with detrimental, short-term and long-term interventions, and complications. Central and subtotal pancreatic necrosis and high levels of serum C-reactive protein in the first 48 hours are independent predictors for DPD.Cellular mechanisms in basic and clinical gastroenterology and hepatolog

    Impact of nationwide enhanced implementation of best practices in pancreatic cancer care (PACAP-1): A multicenter stepped-wedge cluster randomized controlled trial

    Get PDF
    Background: Pancreatic cancer has a very poor prognosis. Best practices for the use of chemotherapy, enzyme replacement therapy, and biliary drainage have been identified but their implementation in daily clinical practice is often suboptimal. We hypothesized that a nationwide program to enhance implementation of these best practices in pancreatic cancer care would improve survival and quality of life. Methods/design: PACAP-1 is a nationwide multicenter stepped-wedge cluster randomized controlled superiority trial. In a per-center stepwise and randomized manner, best practices in pancreatic cancer care regarding the use of (neo)adjuvant and palliative chemotherapy, pancreatic enzyme replacement therapy, and metal biliary stents are implemented in all 17 Dutch pancreatic centers and their regional referral networks during a 6-week initiation period. Per pancreatic center, one multidisciplinary team functions as reference for the other centers in the network. Key best practices were identified from the literature, 3 years of data from existing nationwide registries within the Dutch Pancreatic Cancer Project (PACAP), and national expert meetings. The best practices follow the Dutch guideline on pancreatic cancer and the current state of the literature, and can be executed within daily clinical practice. The implementation process includes monitoring, return visits, and provider feedback in combination with education and reminders. Patient outcomes and compliance are monitored within the PACAP registries. Primary outcome is 1-year overall survival (for all disease stages). Secondary outcomes include quality of life, 3- and 5-year overall survival, and guideline compliance. An improvement of 10% in 1-year overall survival is considered clinically relevant. A 25-month study duration was chosen, which provides 80% statistical power for a mortality reduction of 10.0% in the 17 pancreatic cancer centers, with a required sample size of 2142 patients, corresponding to a 6.6% mortality reduction and 4769 patients nationwide. Discussion: The PACAP-1 trial is designed to evaluate whether a nationwide program for enhanced implementation of best practices in pancreatic cancer care can improve 1-year overall survival and quality of life. Trial registration: ClinicalTrials.gov, NCT03513705. Trial opened for accrual on 22th May 2018

    Anisotropy studies around the galactic centre at EeV energies with the Auger Observatory

    Get PDF
    Data from the Pierre Auger Observatory are analyzed to search for anisotropies near the direction of the Galactic Centre at EeV energies. The exposure of the surface array in this part of the sky is already significantly larger than that of the fore-runner experiments. Our results do not support previous findings of localized excesses in the AGASA and SUGAR data. We set an upper bound on a point-like flux of cosmic rays arriving from the Galactic Centre which excludes several scenarios predicting sources of EeV neutrons from Sagittarius AA. Also the events detected simultaneously by the surface and fluorescence detectors (the `hybrid' data set), which have better pointing accuracy but are less numerous than those of the surface array alone, do not show any significant localized excess from this direction.Comment: Matches published versio

    The Fluorescence Detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.Comment: 53 pages. Submitted to Nuclear Instruments and Methods in Physics Research Section

    Update on the correlation of the highest energy cosmic rays with nearby extragalactic matter

    Get PDF
    Data collected by the Pierre Auger Observatory through 31 August 2007 showed evidence for anisotropy in the arrival directions of cosmic rays above the Greisen-Zatsepin-Kuz'min energy threshold, \nobreak{6×10196\times 10^{19}eV}. The anisotropy was measured by the fraction of arrival directions that are less than 3.1∘3.1^\circ from the position of an active galactic nucleus within 75 Mpc (using the V\'eron-Cetty and V\'eron 12th12^{\rm th} catalog). An updated measurement of this fraction is reported here using the arrival directions of cosmic rays recorded above the same energy threshold through 31 December 2009. The number of arrival directions has increased from 27 to 69, allowing a more precise measurement. The correlating fraction is (38−6+7)(38^{+7}_{-6})%, compared with 2121% expected for isotropic cosmic rays. This is down from the early estimate of (69−13+11)(69^{+11}_{-13})%. The enlarged set of arrival directions is examined also in relation to other populations of nearby extragalactic objects: galaxies in the 2 Microns All Sky Survey and active galactic nuclei detected in hard X-rays by the Swift Burst Alert Telescope. A celestial region around the position of the radiogalaxy Cen A has the largest excess of arrival directions relative to isotropic expectations. The 2-point autocorrelation function is shown for the enlarged set of arrival directions and compared to the isotropic expectation.Comment: Accepted for publication in Astroparticle Physics on 31 August 201

    Advanced functionality for radio analysis in the Offline software framework of the Pierre Auger Observatory

    Get PDF
    The advent of the Auger Engineering Radio Array (AERA) necessitates the development of a powerful framework for the analysis of radio measurements of cosmic ray air showers. As AERA performs "radio-hybrid" measurements of air shower radio emission in coincidence with the surface particle detectors and fluorescence telescopes of the Pierre Auger Observatory, the radio analysis functionality had to be incorporated in the existing hybrid analysis solutions for fluoresence and surface detector data. This goal has been achieved in a natural way by extending the existing Auger Offline software framework with radio functionality. In this article, we lay out the design, highlights and features of the radio extension implemented in the Auger Offline framework. Its functionality has achieved a high degree of sophistication and offers advanced features such as vectorial reconstruction of the electric field, advanced signal processing algorithms, a transparent and efficient handling of FFTs, a very detailed simulation of detector effects, and the read-in of multiple data formats including data from various radio simulation codes. The source code of this radio functionality can be made available to interested parties on request.Comment: accepted for publication in NIM A, 13 pages, minor corrections to author list and references in v

    Search for First Harmonic Modulation in the Right Ascension Distribution of Cosmic Rays Detected at the Pierre Auger Observatory

    Get PDF
    We present the results of searches for dipolar-type anisotropies in different energy ranges above 2.5×10172.5\times 10^{17} eV with the surface detector array of the Pierre Auger Observatory, reporting on both the phase and the amplitude measurements of the first harmonic modulation in the right-ascension distribution. Upper limits on the amplitudes are obtained, which provide the most stringent bounds at present, being below 2% at 99% C.L.C.L. for EeV energies. We also compare our results to those of previous experiments as well as with some theoretical expectations.Comment: 28 pages, 11 figure

    Nationwide practice and outcomes of endoscopic biliary drainage in resectable pancreatic head and periampullary cancer

    Get PDF
    Background: Guidelines advise self-expanding metal stents (SEMS) over plastic stents in preoperative endoscopic biliary drainage (EBD) for malignant extrahepatic biliary obstruction. This study aims to assess nationwide practice and outcomes. Methods: Patients with pancreatic head and periampullary cancer who underwent EBD before pancreatoduodenectomy were included from the Dutch Pancreatic Cancer Audit (2017–2018). Multivariable logistic and linear regression models were performed. Results: In total, 575/1056 patients (62.0%) underwent preoperative EBD: 246 SEMS (42.8%) and 329 plastic stents (57.2%). EBD-related complications were comparable between the groups (44/246 (17.9%) vs. 64/329 (19.5%), p = 0.607), including pancreatitis (22/246 (8.9%) vs. 25/329 (7.6%), p = 0.387). EBD-related cholangitis was reduced after SEMS placement (10/246 (4.1%) vs. 32/329 (9.7%), p = 0.043), which was confirmed in multivariable analysis (OR 0.36 95%CI 0.15–0.87, p = 0.023). Major postoperative complications did not differ (58/246 (23.6%) vs. 90/329 (27.4%), p = 0.316), whereas postoperative pancreatic fistula (24/246 (9.8%) vs. 61/329 (18.5%), p = 0.004; OR 0.50 95%CI 0.27–0.94, p = 0.031) and hospital stay (14.0 days vs. 17.4 days, p = 0.005; B 2.86 95%CI −5.16 to −0.57, p = 0.014) were less after SEMS placement. Conclusion: This study found that preoperative EBD frequently involved plastic stents. SEMS seemed associated with lower risks of cholangitis and less postoperative pancreatic fistula, but without an increased pancreatitis risk

    Clip placement to prevent delayed bleeding after colonic endoscopic mucosal resection (CLIPPER): study protocol for a randomized controlled trial

    Get PDF
    Background: Endoscopic mucosal resection (EMR) for large colorectal polyps is in most cases the preferred treatment to prevent progression to colorectal carcinoma. The most common complication after EMR is delayed bleeding, occurring in 7% overall and in approximately 10% of polyps ≄ 2 cm in the proximal colon. Previous research has suggested that prophylactic clipping of the mucosal defect after EMR may reduce the incidence of delayed bleeding in polyps with a high bleeding risk. Methods: The CLIPPER trial is a multicenter, parallel-group, single blinded, randomized controlled superiority study. A total of 356 patients undergoing EMR for large (≄ 2 cm) non-pedunculated polyps in the proximal colon will be included and randomized to the clip group or the control group. Prophylactic clipping will be performed in the intervention group to close the resection defect after the EMR with a distance of < 1 cm between the clips. Primary outcome is delayed bleeding within 30 days after EMR. Secondary outcomes are recurrent or residual polyps and clip artifacts during surveillance colonoscopy after 6 months, as well as cost-effectiveness of prophylactic clipping and severity of delayed bleeding. Discussion: The CLIPPER trial is a pragmatic study performed in the Netherlands and is powered to determine the real-time efficacy and cost-effectiveness of prophylactic clipping after EMR of proximal colon polyps ≄ 2 cm in the Netherlands. This study will also generate new data on the achievability of complete closure and the effects of clip placement on scar surveillance after EMR, in order to further promote the debate on the role of prophylactic clipping in everyday clinical practice. Trial registration: ClinicalTrials.gov NCT03309683. Registered on 13 October 2017. Start recruitment: 05 March 2018. Planned completion of recruitment: 31 August 2021
    • 

    corecore