580 research outputs found

    Three Dimensional Electrical Impedance Tomography

    Get PDF
    The electrical resistivity of mammalian tissues varies widely and is correlated with physiological function. Electrical impedance tomography (EIT) can be used to probe such variations in vivo, and offers a non-invasive means of imaging the internal conductivity distribution of the human body. But the computational complexity of EIT has severe practical limitations, and previous work has been restricted to considering image reconstruction as an essentially two-dimensional problem. This simplification can limit significantly the imaging capabilities of EIT, as the electric currents used to determine the conductivity variations will not in general be confined to a two-dimensional plane. A few studies have attempted three-dimensional EIT image reconstruction, but have not yet succeeded in generating images of a quality suitable for clinical applications. Here we report the development of a three-dimensional EIT system with greatly improved imaging capabilities, which combines our 64-electrode data-collection apparatus with customized matrix inversion techniques. Our results demonstrate the practical potential of EIT for clinical applications, such as lung or brain imaging and diagnostic screening

    Estimulação diafragmática elétrica transcutânea (EDET) para fortalecimento muscular respiratório: estudo clínico controlado e randomizado

    Get PDF
    O objetivo do estudo foi demonstrar o efeito de dois protocolos da estimulação diafragmática elétrica transcutânea (EDET) sobre a força muscular respiratória de mulheres saudáveis, sendo um protocolo segundo Geddes et al. (1988) e outro padronizado pelo equipamento Phrenics. Mulheres saudáveis foram divididas em 3 grupos: Controle (n=7); EDET com Phrenics (n=7) e EDET com Dualpex (n=7), sendo o tratamento realizado 2 vezes por semana, durante 6 semanas (12 sessões). Foram avaliadas a pressão inspiratória máxima (PImáx) e pressão expiratória máxima (PEmáx), antes e após o tratamento. A análise estatística foi realizada pelo teste Shapiro-Wilk e Kruskal Wallis com pós-hoc de Dunn (p<0,05). Os dois grupos experimentais apresentaram aumento na PImáx (Phrenics: 32,9%; Dualpex: 63,2%) e na PEmáx (Phrenics: 44,7%; Dualpex: 60,9%), diferentemente do Controle que não apresentou diferença. Em conclusão, os dois protocolos de EDET promoveram aumento da força muscular inspiratória e expiratória em mulheres saudáveis

    Dynamics of early establishment of SARS-CoV-2 VOC Omicron lineages in Minas Gerais, Brazil

    Get PDF
    Brazil is one of the nations most affected by Coronavirus disease 2019 (COVID-19). The introduction and establishment of new virus variants can be related to an increase in cases and fatalities. The emergence of Omicron, the most modified SARS-CoV-2 variant, caused alarm for the public health of Brazil. In this study, we examined the effects of the Omicron introduction in Minas Gerais (MG), the second-most populous state of Brazil. A total of 430 Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) samples from November 2021 to June 2022 from Belo Horizonte (BH) city were sequenced. These newly sequenced genomes comprise 72% of all previously available SARS-CoV-2 genomes for the city. Evolutionary analysis of novel viral genomes reveals that a great diversity of Omicron sublineages have circulated in BH, a pattern in-keeping with observations across Brazil more generally. Bayesian phylogeographic reconstructions indicate that this diversity is a product of a large number of international and national importations. As observed previously, São Paulo state is shown as a significant hub for viral spread throughout the country, contributing to around 70% of all viral Omicron introductions detected in MG

    Improving prehospital trauma management for skiers and snowboarders - need for on-slope triage?

    Get PDF
    Background Injuries from skiing and snowboarding became a major challenge for emergency care providers in Switzerland. In the alpine setting, early assessment of injury and health status is essential for the initiation of adequate means of care and transport. Nevertheless, validated standardized protocols for on-slope triage are missing. This article can assist in understanding the characteristics of injured winter sportsmen and exigencies for future on-slope triage protocols. Methods Six-year review of trauma cases in a tertiary trauma centre. Consecutive inclusion of all injured skiers and snowboarders aged >15 (total sample) years with predefined, severe injury to the head, spine, chest, pelvis or abdomen (study sample) presenting at or being transferred to the study hospital. Descriptive analysis of age, gender and injury pattern. Results Amongst 729 subjects (total sample) injured from skiing or snowboarding, 401 (55%, 54% of skiers and 58% of snowboarders) suffered from isolated limb injury. Amongst the remaining 328 subjects (study sample), the majority (78%) presented with monotrauma. In the study sample, injury to the head (52%) and spine (43%) was more frequent than injury to the chest (21%), pelvis (8%), and abdomen (5%). The three most frequent injury combinations were head/spine (10% of study sample), head/thorax (9%), and spine/thorax (6%). Fisher's exact test demonstrated an association for injury combinations of head/thorax (p < 0.001), head/abdomen (p = 0.019), and thorax/abdomen (p < 0.001). Conclusion The data presented and the findings from previous investigations indicate the need for development of dedicated on-slope triage protocols. Future research must address the validity and practicality of diagnostic on-slope tests for rapid decision making by both professional and lay first responders. Thus, large-scale and detailed injury surveillance is the future research priority

    Measurement of the branching fraction and CP content for the decay B(0) -> D(*+)D(*-)

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APS.We report a measurement of the branching fraction of the decay B0→D*+D*- and of the CP-odd component of its final state using the BABAR detector. With data corresponding to an integrated luminosity of 20.4  fb-1 collected at the Υ(4S) resonance during 1999–2000, we have reconstructed 38 candidate signal events in the mode B0→D*+D*- with an estimated background of 6.2±0.5 events. From these events, we determine the branching fraction to be B(B0→D*+D*-)=[8.3±1.6(stat)±1.2(syst)]×10-4. The measured CP-odd fraction of the final state is 0.22±0.18(stat)±0.03(syst).This work is supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the A.P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    Measurement of D-s(+) and D-s(*+) production in B meson decays and from continuum e(+)e(-) annihilation at √s=10.6 GeV

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APSNew measurements of Ds+ and Ds*+ meson production rates from B decays and from qq̅ continuum events near the Υ(4S) resonance are presented. Using 20.8 fb-1 of data on the Υ(4S) resonance and 2.6 fb-1 off-resonance, we find the inclusive branching fractions B(B⃗Ds+X)=(10.93±0.19±0.58±2.73)% and B(B⃗Ds*+X)=(7.9±0.8±0.7±2.0)%, where the first error is statistical, the second is systematic, and the third is due to the Ds+→φπ+ branching fraction uncertainty. The production cross sections σ(e+e-→Ds+X)×B(Ds+→φπ+)=7.55±0.20±0.34pb and σ(e+e-→Ds*±X)×B(Ds+→φπ+)=5.8±0.7±0.5pb are measured at center-of-mass energies about 40 MeV below the Υ(4S) mass. The branching fractions ΣB(B⃗Ds(*)+D(*))=(5.07±0.14±0.30±1.27)% and ΣB(B⃗Ds*+D(*))=(4.1±0.2±0.4±1.0)% are determined from the Ds(*)+ momentum spectra. The mass difference m(Ds+)-m(D+)=98.4±0.1±0.3MeV/c2 is also measured.This work was supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the Swiss NSF, A. P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore