29 research outputs found

    High-field MR imaging in pediatric congenital heart disease: Initial results

    Get PDF
    BackgroundComprehensive assessment of pediatric congenital heart disease (CHD) at any field strength mandates evaluation of both vascular and dynamic cardiac anatomy for which diagnostic quality contrast-enhanced magnetic resonance angiography (CEMRA) and cardiac cine are crucial.ObjectiveTo determine whether high-resolution (HR) CEMRA and steady-state free precession (SSFP) cine can be performed reliably at 3.0 T in children with CHD and to compare the image quality to similar techniques performed at 1.5 T.Materials and methodsTwenty-eight patients with a median age of 5 months and average weight 9.0 ± 7.8 kg with suspected or known CHD were evaluated at 3.0 T. SSFP cine (n = 86 series) and HR-CEMRA (n = 414 named vascular segments) were performed and images were scored for image quality and artifacts. The findings were compared to those of 28 patients with CHD of similar weight who were evaluated at 1.5 T.ResultsOverall image quality on HR-CEMRA was rated as excellent or good in 96% (397/414) of vascular segments at 3.0 T (k = 0.49) and in 94% (349/371) of vascular segments at 1.5 T (k = 0.36). Overall image quality of SSFP was rated excellent or good in 91% (78/86) of cine series at 3.0 T (k = 0.55) and in 81% (87/108) at 1.5 T (k = 0.47). Off-resonance artifact was common at both field strengths, varied over the cardiac cycle and was more prevalent at 3.0 T. At 3.0 T, off-resonance dark band artifact on SSFP cine was absent in 3% (3/86), mild in 69% (59/86), moderate in 27% (23/86) and severe in 1% (1/86) of images; at 1.5 T, dark band artifact was absent in 16% (17/108), mild in 69% (75/108), moderate in 12% (13/108) and severe in 3% (3/108) of cine images. The signal-to-noise ratio and contrast-to-noise ratio of both SSFP cine and HR-CEMRA images were significantly higher at 3.0 T than at 1.5 T (P < 0.001).ConclusionSignal-to-noise ratio and contrast-to-noise ratio of high-resolution contrast-enhanced magnetic resonance angiography and SSFP cine were higher at 3.0 T than at 1.5 T. Artifacts on SSFP cine were cardiac phase specific and more prevalent at 3.0 T such that frequency-tuning was required in one-third of exams. In neonates, high spatial resolution CEMRA was highly reliable in defining extracardiac vascular anatomy

    4D MUSIC CMR: value-based imaging of neonates and infants with congenital heart disease

    Get PDF
    Abstract Background 4D Multiphase Steady State Imaging with Contrast (MUSIC) acquires high-resolution volumetric images of the beating heart during uninterrupted ventilation. We aim to evaluate the diagnostic performance and clinical impact of 4D MUSIC in a cohort of neonates and infants with congenital heart disease (CHD). Methods Forty consecutive neonates and infants with CHD (age range 2 days to 2 years, weight 1 to 13 kg) underwent 3.0 T CMR with ferumoxytol enhancement (FE) at a single institution. Independently, two readers graded the diagnostic image quality of intra-cardiac structures and related vascular segments on FE-MUSIC and breath held FE-CMRA images using a four-point scale. Correlation of the CMR findings with surgery and other imaging modalities was performed in all patients. Clinical impact was evaluated in consensus with referring surgeons and cardiologists. One point was given for each of five key outcome measures: 1) change in overall management, 2) change in surgical approach, 3) reduction in the need for diagnostic catheterization, 4) improved assessment of risk-to-benefit for planned intervention and discussion with parents, 5) accurate pre-procedural roadmap. Results All FE-CMR studies were completed successfully, safely and without adverse events. On a four-point scale, the average FE-MUSIC image quality scores were >3.5 for intra-cardiac structures and >3.0 for coronary arteries. Intra-cardiac morphology and vascular anatomy were well visualized with good interobserver agreement (r = 0.46). Correspondence between the findings on MUSIC, surgery, correlative imaging and autopsy was excellent. The average clinical impact score was 4.2 ± 0.9. In five patients with discordant findings on echo/MUSIC (n = 5) and catheter angiography/MUSIC (n = 1), findings on FE-MUSIC were shown to be accurate at autopsy (n = 1) and surgery (n = 4). The decision to undertake biventricular vs univentricular repair was amended in 2 patients based on FE-MUSIC findings. Plans for surgical approaches which would have involved circulatory arrest were amended in two of 28 surgical cases. In all 28 cases requiring procedural intervention, FE-MUSIC provided accurate dynamic 3D roadmaps and more confident risk-to-benefit assessments for proposed interventions. Conclusions FE-MUSIC CMR has high clinical impact by providing accurate, high quality, simple and safe dynamic 3D imaging of cardiac and vascular anatomy in neonates and infants with CHD. The findings influenced patient management in a positive manner

    Development Of Quality Metrics For Ambulatory Care In Pediatric Patients With Tetralogy Of Fallot

    No full text
    Objective: The objective of this study was to develop quality metrics (QMs) relating to the ambulatory care of children after complete repair of tetralogy of Fallot (TOF). Design: A workgroup team (WT) of pediatric cardiologists with expertise in all aspects of ambulatory cardiac management was formed at the request of the American College of Cardiology (ACC) and the Adult Congenital and Pediatric Cardiology Council (ACPC), to review published guidelines and consensus data relating to the ambulatory care of repaired TOF patients under the age of 18 years. A set of quality metrics (QMs) was proposed by the WT. The metrics went through a two-step evaluation process. In the first step, the RAND-UCLA modified Delphi methodology was employed and the metrics were voted on feasibility and validity by an expert panel. In the second step, QMs were put through an “open comments” process where feedback was provided by the ACPC members. The final QMs were approved by the ACPC council. Results: The TOF WT formulated 9 QMs of which only 6 were submitted to the expert panel; 3 QMs passed the modified RAND-UCLA and went through the “open comments” process. Based on the feedback through the open comment process, only 1 metric was finally approved by the ACPC council. Conclusions: The ACPC Council was able to develop QM for ambulatory care of children with repaired TOF. These patients should have documented genetic testing for 22q11.2 deletion. However, lack of evidence in the literature made it a challenge to formulate other evidence-based QMs
    corecore