48 research outputs found

    Pliocene and Pleistocene geologic and climatic evolution in the San Luis Valley of south-central Colorado

    Full text link
    Sediments of the Alamosa Formation spanning the upper part of the Gauss and most of the Matuyama Chrons were recovered by coring in the high (2300 m) San Luis Valley of south-central Colorado. The study site is located at the northern end of the Rio Grande rift. Lithologic changes in the core sediments provide evidence of events leading to integration of the San Luis drainage basin into the Rio Grande. The section, which includes the Huckleberry Ridge Ash (2.02 Ma) and spans the entire Matuyama Chron, contains pollen, and invertebrate and vertebrate fossils. Stable isotope analyses of inorganic and biogenic carbonate taken over most of the core indicate substantially warmer temperatures than occur today in the San Luis Valley. At the end of the Olduvai Subchron, summer precipitation decreased, summer pan evaporation increased, and temperatures increased slightly compared to the earlier climate represented in the core. By the end of the Jaramillo Subchron, however, cold/wet and warm/dry cycles become evident and continue into the cold/wet regime associated with the deep-sea oxygen-isotope Stage 22 glaciation previously determined from outcrops at the same locality. Correspondence between the Hansen Bluff climatic record and the deep-sea oxygen-isotope record (oxygen-isotope stages from about 110-18) is apparent, indicating that climate at Hansen Bluff was responding to global climatic changes.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/29956/1/0000316.pd

    The US Program in Ground-Based Gravitational Wave Science: Contribution from the LIGO Laboratory

    Get PDF
    Recent gravitational-wave observations from the LIGO and Virgo observatories have brought a sense of great excitement to scientists and citizens the world over. Since September 2015,10 binary black hole coalescences and one binary neutron star coalescence have been observed. They have provided remarkable, revolutionary insight into the "gravitational Universe" and have greatly extended the field of multi-messenger astronomy. At present, Advanced LIGO can see binary black hole coalescences out to redshift 0.6 and binary neutron star coalescences to redshift 0.05. This probes only a very small fraction of the volume of the observable Universe. However, current technologies can be extended to construct "3rd Generation" (3G) gravitational-wave observatories that would extend our reach to the very edge of the observable Universe. The event rates over such a large volume would be in the hundreds of thousands per year (i.e. tens per hour). Such 3G detectors would have a 10-fold improvement in strain sensitivity over the current generation of instruments, yielding signal-to-noise ratios of 1000 for events like those already seen. Several concepts are being studied for which engineering studies and reliable cost estimates will be developed in the next 5 years

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Search for gravitational-lensing signatures in the full third observing run of the LIGO-Virgo network

    Get PDF
    Gravitational lensing by massive objects along the line of sight to the source causes distortions of gravitational wave-signals; such distortions may reveal information about fundamental physics, cosmology and astrophysics. In this work, we have extended the search for lensing signatures to all binary black hole events from the third observing run of the LIGO--Virgo network. We search for repeated signals from strong lensing by 1) performing targeted searches for subthreshold signals, 2) calculating the degree of overlap amongst the intrinsic parameters and sky location of pairs of signals, 3) comparing the similarities of the spectrograms amongst pairs of signals, and 4) performing dual-signal Bayesian analysis that takes into account selection effects and astrophysical knowledge. We also search for distortions to the gravitational waveform caused by 1) frequency-independent phase shifts in strongly lensed images, and 2) frequency-dependent modulation of the amplitude and phase due to point masses. None of these searches yields significant evidence for lensing. Finally, we use the non-detection of gravitational-wave lensing to constrain the lensing rate based on the latest merger-rate estimates and the fraction of dark matter composed of compact objects

    Search for eccentric black hole coalescences during the third observing run of LIGO and Virgo

    Get PDF
    Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass M>70 M⊙) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities 0<e≤0.3 at 0.33 Gpc−3 yr−1 at 90\% confidence level

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    The influence of blood storage time and general anaesthesia on chromosomal radiosensitivity assessment

    No full text
    The micronucleus assay (MN assay) is a well-established assay in genetic toxicology, biomonitoring of mutagen-exposed populations and chromosomal radiosensitivity testing. To evaluate the effect of storage time on the chromosomal radiosensitivity assessment in lymphocytes, micronuclei (MN) yields in blood samples received and processed on the same day were compared with MN yields obtained when blood cultures were set up 24 and 48h after blood sampling. Furthermore, the influence of general anaesthesia on MN and binucleated cells (BN) yields in the MN assay was considered. Blood samples of 10 healthy donors were irradiated and blood cultures were set up during the same day of blood sampling or with a delay of 24 or 48h. The MN assay was also performed on two blood samples from 60 women undergoing breast surgery. The first blood sample was taken before general anaesthesia and the second sample, 2h after anaesthesia induction. Fifty percent of the blood samples were transported to the cytogenetics lab within 2h while the other 50% reached the lab after 24h. The results of this study show a decrease in BN and an increase in MN yields with increasing storage time before irradiation and setting up of the MN assay for both healthy controls and patients. The administration of general anaesthesia in patients resulted in lower BN yields, higher spontaneous MN yields but no differences in radiation-induced MN yields. In conclusion, this study indicates that the time between blood sampling and the in vitro irradiation of the samples for the MN assay influences the MN yields. Delays of more than 24h should be avoided. To assess chromosomal radiosensitivity in patients, blood samples should be taken before induction of general anaesthesia as anaesthesia can have an impact on the reliability of the MN results
    corecore