1,254 research outputs found
Exercise Addiction and Alexithymia
Before presenting this investigation on exercise addiction and alexithymia, the topic of addiction is
introduced by recalling a few terminological distinctions and some questions on aetiology. The investigation
is focused on the relationship between alexithymia and other forms of addiction and between sporting
activity and alexithymia. The sample of research consider 137 subjects attending various gyms in the city.
The hypothesis are the following: 1 Existence of a correlation between alexithymia and exercise addiction. 2
Propensity of alexithymics and addicteds subjects for individual sports and repetitive exercises. 3:
Motivations to practice sport not articulated and without affective quality. The results has confirmed the
hypothesis
In vivo evaluation of operative torque generated by two Nickel-Titanium rotary instruments during root canal preparation
Objectives This in vivo study evaluated the operative torque and preparation time of ProTaper NEXT (Dentsply Maillefer; Ballaigues, Switzerland) and EdgeFile X7 (EdgeEndo; Albuquerque, New Mexico, United States) rotary systems during root canal preparation of maxillary premolars. Materials and Methods Ten double-rooted maxillary premolars with independent canals were selected. Each canal in each tooth was prepared with one of the rotary systems (n = 10), ProTaper NEXT or EdgeFile X7. The instruments were rotated at 300 rpm with maximum torque set at 2 N.cm using an electric motor (KaVo; Biberach, Germany) that automatically recorded torque values at every 1/10th of a second (ds). Statistical Analysis Operative torque (N.cm) and preparation time (s) of the first shaping instrument (size 17/.04) of both rotary systems were recorded and statistically compared using the Mann-Whiney U test with a significance level set at 5%. Results No instrument exhibited flute deformation or underwent intracanal failure. No differences were found between the instruments regarding the maximum (peak) torque values (p > 0.05). EdgeFile X7 17/.04 required significantly less preparation time (3.75 seconds interquartile range [IQR]: 3.2-9.0) than ProTaper NEXT X1 (15.45 seconds IQR: 8.35-21.1) (p < 0.05). The median operative torque values of ProTaper NEXT X1 (0.26 N.cm; IQR: 0.18-0.49) were significantly higher compared with EdgeFile X7 17/.04 (0.09 N.cm; IQR: 0.05-0.17) (p < 0.05). Conclusions Although no difference was found between the median peak torque values of ProTaper NEXT X1 and EdgeFile X7 17/.04 instruments, the operative torque and instrumentation time results were impacted by their different designs and alloys during clinical preparation of root canals
New technologies to improve root canal disinfection
Effective irrigant delivery and agitation are prerequisites to promote root canal disinfection and debris removal and improve successful endodontic treatment. This paper presents an overview of the currently available technologies to improve the cleaning of the endodontic space and their debridement efficacy. A PubMed electronic search was conducted with appropriate key words to identify the relevant literature on this topic. After retrieving the full-text articles, all the articles were reviewed and the most appropriate were included in this review. Several different systems of mechanical activation of irrigants to improve endodontic disinfection were analysed: manual agitation with gutta-percha cones, endodontic instruments or special brushes, vibrating systems activated by low-speed hand-pieces or by sonic or subsonic energy, use of ultrasonic or laser energy to mechanically activate the irrigants and apical negative pressure irrigation systems. Furthermore, this review aims to describe systems designed to improve the intracanal bacterial decontamination by a specific chemical action, such as ozone, direct laser action or light-activated disinfection. The ultrasonic activation of root canal irrigants and of sodium hypochlorite in particular still remains the gold standard to which all other systems of mechanical agitation analyzed in this article were compared. From this overview, it is evident that the use of different irrigation systems can provide several advantages in the clinical endodontic outcome and that integration of new technologies, coupled with enhanced techniques and materials, may help everyday clinical practice
Fatigue resistance of new and used nickel-titanium rotary instruments: a comparative study
Aim of the present study was twofold. First, to evaluate in vitro, the performance of two different NiTi rotary instruments in one molar case; then, to evaluate their resistance to cyclic fatigue, compared to new ones
Cyclic Fatigue of Different Nickel-Titanium Rotary Instruments: A Comparative Study
Since the introduction of nickel-titanium alloy to endodontics, there have been many changes in instrument design, but no significant improvements in the raw material properties, or enhancements in the manufacturing process. Recently, a new method to produce nickel-titanium rotary (NTR) instruments has been developed, in an attempt to obtain instruments that are more flexible and resistant to fatigue. NTR instruments produced using the process of twisting (TF, SybronEndo, Orange, CA) were compared to NTR instruments from different manufacturers produced by a traditional grinding process. The aim of the study was to investigate whether cyclic fatigue resistance is increased for TF NTR files. Tests were performed with a cyclic fatigue device that evaluated cycles to failure of rotary instruments inside curved artificial canals. Results indicated that size 06-25 TF instruments showed a significant increase (P< .05). In the mean number of cycles to failurewhen compared to the other tested 06-25 NTR. Hence, it can be concluded that size 06-25 TF NTR instruments were found to be significantly more resistant to fatigue than those produced with the traditional grinding process
Role of the flat-designed surface in improving the cyclic fatigue resistance of endodontic NiTi rotary instruments
The aim of this study was to investigate the role of the flat-designed surface in improving the resistance to cyclic fatigue by comparing heat-treated F-One (Fanta Dental, Shanghai, China) nickel-titanium (NiTi) rotary instruments and similar prototypes, differing only by the absence of the flat side. The null hypothesis was that there were no differences between the two tested instruments in terms of cyclic fatigue lifespan. A total of 40 new NiTi instruments (20 F-One and 20 prototypes) were tested in the present study. The instruments were rotated with the same speed (500 rpm) and torque (2 N) using an endodontic motor (Elements Motor, Kerr, Orange, CA, USA) in the same stainless steel, artificial canal (90° angle of curvature and 5 mm radius). A Wilcoxon-Mann-Whitney test was performed to assess the differences in terms of time to fracture and the length of the fractured segment between the flat- and non-flat-sided instruments. Significance was set at p = 0.05. The differences in terms of time to fracture between non-flat and flat were statistically significant (p < 0.001). In addition, the differences in terms of fractured segment length were statistically significant (p = 0.034). The results of this study highlight the importance of flat-sided design in increasing the cyclic fatigue lifespan of NiTi rotary instruments
In vitro evaluation of carrier based obturation technique: a CBCT study
AIM:
The goal of the study was to compare the ability of two different carrier based obturation (CBO) techniques to reach working length and fill in three-dimensions root canal systems, by using CBCT.
MATERIALS AND METHODS:
Twenty-six extracted molars were scanned with CBCT and 40 curved canals were selected (between 30° and 90°) and divided in two similar groups (n=20). All canals were prepared up to size 25 taper .06 using nickel-titanium instrumentation. The canals in the Group SC were obturated using Soft-Core obturators (Kerr, Romulus, Mi, USA), while Group TH canals (n= 20) were obturated using Thermafil Endodontic Obturators (Tulsa Dental Products, Tulsa, OK, USA), strictly following manufacturers' instructions for use. The obturations were analyzed by means of CBCT to measure the distance from the apical limit of obturation to the apical foramen and the presence of voids inside root canals.
RESULTS:
There was no significant difference between the two groups in the mean distance of the apical extent of the obturation (t test, p>0.05). Overfilling occurred in only 3 cases (2 in Group TH and 1 in Group SC). The percentages of voids in both groups were very low with no significant difference (Z test, p>0.05).
CONCLUSIONS:
The two tested CBO techniques showed similar positive results in terms of performance, even if, after checking with verifiers, in most cases the size of the selected Soft-Core obturator was one size smaller than Thermafil
Anatomic Two-dimensional and Three-dimensional Models for Cyclic Fatigue Testing of Endodontic Instruments
Introduction: In this study, new devices were developed and evaluated for cyclic fatigue testing (CTF) of endodontic instruments in two-dimensional (2D) and three-dimensional (3D) replicas of the internal anatomy of a mesial root of a mandibular molar. Methods and Materials: The trajectories of both curved mesial canals of the same root were outlined from computed tomographic scans and exported to a computer assisted drawing (CAD) software. In the CAD program, the canals were virtually enlarged to a size 25/0.06. The CTF devices were then prototyped in stainless steel. The 2D models represented the bucco-lingual (BL) and mesio-distal (MD) views of the canals, while the original trajectory was kept in the 3D model. Vortex Blue 25/0.06 instruments were tested for fatigue in the six canals (n=12). The number of cycles to failure (NCF) and fragment length (mm) were recorded. Data was statistically analyzed (ANOVA and post-hoc Games-Howell test) with the level of significance set at 5%. Results: The mean NCF was significantly different among all the canals (P<0.05). The lifespan of the files was greater in the 2D-BL models, followed by the 2D-MD and 3D. The mean fragment length was also different among the tested models (P<0.05). Conclusions: The tested 2D and 3D representations of the same canal trajectory resulted in significant differences both in the amount of stress (seen from NCF) and localization of the maximum stress (seen from fragment length). Further investigations are required to better understand the effects of different 3D curvatures on the cyclic fatigue of endodontic instruments.Keywords: Cyclic Fatigue; Dental Instruments; Endodontics; Nickel-Titaniu
- …