661 research outputs found

    Energy storage solutions for offshore wave and tidal energy prototypes

    Get PDF
    This paper investigates the motivations for energy storage solutions for offshore Wave Energy Converters (WEC) and tidal energy prototypes. It examines the power and energy storage solutions on offer for developers to aid them during the design stage. Energy storage solutions examined include lead acid batteries, lithium ion batteries, supercapacitors, lithium ion capacitors and diesel for diesel generators. A focus is placed on key installation, operation and maintenance requirements associated with the apparent suitable technologies which are often overlooked. A case study examining a tidal developer's energy storage needs is then presented

    Characterization and calibration of the James Webb space telescope mirror actuators fine stage motion

    Get PDF
    The James Webb Space Telescope’s (Webb’s) deployable primary and secondary mirrors are actively controlled to achieve and maintain precise optical alignment on-orbit. Each of the 18 primary mirror segment assemblies (PMSAs) and the secondary mirror assembly (SMA) are controlled in six degrees of freedom by using six linear actuators in a hexapod arrangement. In addition, each PMSA contains a seventh actuator that adjusts radius of curvature (RoC). The actuators are of a novel stepper motor-based cryogenic two-stage design that is capable of sub-10 nm motion accuracy over a 20 mm range. The nm-level motion of the 132 actuators were carefully tested and characterized before integration into the mirror assemblies. Using these test results as an initial condition, knowledge of each actuator’s length (and therefore mirror position) has relied on software bookkeeping and configuration control to keep an accurate motor step count from which actuator position can be calculated. These operations have been carefully performed through years of Webb test operations using both ground support actuator control software as well as the flight Mirror Control Software (MCS). While the actuator’s coarse stage length is cross-checked using a linear variable differential transformer (LVDT), no on-board cross-check exists for the nm-level length changes of the actuators’ fine stage. To ensure that the software bookkeeping of motor step count is still accurate after years of testing and to test that the actuator position knowledge was properly handed off from the ground software to the flight MCS, a series of optical tests were devised and performed through the Center of Curvature (CoC) ambient optical test campaigns at the Goddard Space Flight Center (GSFC) and during the thermal-vacuum tests of the entire optical payload that were conducted in Chamber A at Johnson Space Center (JSC). In each test, the actuator Fine Step Count (FSC) value is compared to an external measurement provided by an optical metrology tool with the goal of either confirming the MCS database value, or providing a recommendation for an updated calibration if the measured FSC differs significantly from the MCS-based expectation. During ambient testing of the PMSA hexapods, the nm-level actuator length changes were measured with a custom laser deflectometer by measuring tilts of the PMSA. The PMSA RoC fine stage characterization was performed at JSC using multi-wave interferometric measurements with the CoC Optical Assembly (COCOA). Finally, the SMA hexapod fine stage characterization test was performed at JSC using the NIRCam instrument in the “pass-and-a-half” test configuration using a test source from the Aft-Optics System Source Plate Assembly (ASPA). In this paper, each of these three tests, subsequent data analyses, and uncertainty estimations will be presented. Additionally, a summary of the ensemble state of Webb’s actuator fine stages is provided, along with a comparison to a Wavefront Sensing and Control (WFSC)-based requirement for FSC errors as they relate to the optical alignment convergence of the telescope on-orbit

    JWST mirror and actuator performance at cryo-vacuum

    Get PDF
    The James Webb Space Telescope (JWST) telescope’s Secondary Mirror Assembly (SMA) and eighteen Primary Mirror Segment Assemblies (PMSAs) are each actively controlled in rigid body position via six hexapod actuators. Each of the PMSAs additionally has a radius of curvature actuator. The mirrors are stowed to the mirror support structure to survive the launch environment and then must be deployed 12.5 mm to reach the nominally deployed position before the Wavefront Sensing & Control (WFSC) alignment and phasing process begins. JWST requires testing of the full optical system in a Cryogenic Vacuum (CV) environment before launch. The cryo vacuum test campaign was executed in Chamber A at the Johnson Space Center (JSC) in Houston Texas. The test campaign consisted of an ambient vacuum test, a cooldown test, a cryo stable test at 65 Kelvin, a warmup test, and finally a second ambient vacuum test. Part of that test campaign was the functional and performance testing of the hexapod actuators on the flight mirrors. This paper will describe the testing that was performed on all 132 hexapod and radius of curvature actuators. The test campaign first tests actuators individually then tested how the actuators perform in the hexapod system. Telemetry from flight sensors on the actuators and measurements from external metrology devices such as interferometers, photogrammetry systems and image analysis was used to demonstrate the performance of the JWST actuators. The mirror move commanding process was exercised extensively during the JSC CV test and many examples of accurately commanded moves occurred. The PMSA and SMA actuators performed extremely well during the JSC CV test, and we have demonstrated that the actuators are fully functional both at ambient and cryo temperatures and that the mirrors will go to their commanded positions with the accuracy needed to phase and align the telescope

    Characterization and calibration of the James Webb space telescope mirror actuators fine stage motion

    Get PDF
    The James Webb Space Telescope’s (Webb’s) deployable primary and secondary mirrors are actively controlled to achieve and maintain precise optical alignment on-orbit. Each of the 18 primary mirror segment assemblies (PMSAs) and the secondary mirror assembly (SMA) are controlled in six degrees of freedom by using six linear actuators in a hexapod arrangement. In addition, each PMSA contains a seventh actuator that adjusts radius of curvature (RoC). The actuators are of a novel stepper motor-based cryogenic two-stage design that is capable of sub-10 nm motion accuracy over a 20 mm range. The nm-level motion of the 132 actuators were carefully tested and characterized before integration into the mirror assemblies. Using these test results as an initial condition, knowledge of each actuator’s length (and therefore mirror position) has relied on software bookkeeping and configuration control to keep an accurate motor step count from which actuator position can be calculated. These operations have been carefully performed through years of Webb test operations using both ground support actuator control software as well as the flight Mirror Control Software (MCS). While the actuator’s coarse stage length is cross-checked using a linear variable differential transformer (LVDT), no on-board cross-check exists for the nm-level length changes of the actuators’ fine stage. To ensure that the software bookkeeping of motor step count is still accurate after years of testing and to test that the actuator position knowledge was properly handed off from the ground software to the flight MCS, a series of optical tests were devised and performed through the Center of Curvature (CoC) ambient optical test campaigns at the Goddard Space Flight Center (GSFC) and during the thermal-vacuum tests of the entire optical payload that were conducted in Chamber A at Johnson Space Center (JSC). In each test, the actuator Fine Step Count (FSC) value is compared to an external measurement provided by an optical metrology tool with the goal of either confirming the MCS database value, or providing a recommendation for an updated calibration if the measured FSC differs significantly from the MCS-based expectation. During ambient testing of the PMSA hexapods, the nm-level actuator length changes were measured with a custom laser deflectometer by measuring tilts of the PMSA. The PMSA RoC fine stage characterization was performed at JSC using multi-wave interferometric measurements with the CoC Optical Assembly (COCOA). Finally, the SMA hexapod fine stage characterization test was performed at JSC using the NIRCam instrument in the “pass-and-a-half” test configuration using a test source from the Aft-Optics System Source Plate Assembly (ASPA). In this paper, each of these three tests, subsequent data analyses, and uncertainty estimations will be presented. Additionally, a summary of the ensemble state of Webb’s actuator fine stages is provided, along with a comparison to a Wavefront Sensing and Control (WFSC)-based requirement for FSC errors as they relate to the optical alignment convergence of the telescope on-orbit

    Benefits and harms of oral anticoagulant therapy in chronic kidney disease: a systematic review and meta-analysis

    Get PDF
    Background: Effects of oral anticoagulation in chronic kidney disease (CKD) are uncertain. Purpose: To evaluate the benefits and harms of vitamin K antagonists (VKAs) and non–vitamin K oral anticoagulants (NOACs) in adults with CKD stages 3 to 5, including those with dialysis-dependent end-stage kidney disease (ESKD). Data Sources: English-language searches of MEDLINE, EMBASE, and Cochrane databases (inception to February 2019); review bibliographies; and ClinicalTrials.gov (25 February 2019). Study Selection: Randomized controlled trials evaluating VKAs or NOACs for any indication in patients with CKD that reported efficacy or bleeding outcomes. Data Extraction: Two authors independently extracted data, assessed risk of bias, and rated certainty of evidence. Data Synthesis: Forty-five trials involving 34 082 participants who received anticoagulation for atrial fibrillation (AF) (11 trials), venous thromboembolism (VTE) (11 trials), thromboprophylaxis (6 trials), prevention of dialysis access thrombosis (8 trials), and cardiovascular disease other than AF (9 trials) were included. All but the 8 trials involving patients with ESKD excluded participants with creatinine clearance less than 20 mL/min or estimated glomerular filtration rate less than 15 mL/min/1.73 m2. In AF, compared with VKAs, NOACs reduced risks for stroke or systemic embolism (risk ratio [RR], 0.79 [95% CI, 0.66 to 0.93]; high-certainty evidence) and hemorrhagic stroke (RR, 0.48 [CI, 0.30 to 0.76]; moderate-certainty evidence). Compared with VKAs, the effects of NOACs on recurrent VTE or VTE-related death were uncertain (RR, 0.72 [CI, 0.44 to 1.17]; low-certainty evidence). In all trials combined, NOACs seemingly reduced major bleeding risk compared with VKAs (RR, 0.75 [CI, 0.56 to 1.01]; low-certainty evidence). Limitation: Scant evidence for advanced CKD or ESKD; data mostly from subgroups of large trials. Conclusion: In early-stage CKD, NOACs had a benefit–risk profile superior to that of VKAs. For advanced CKD or ESKD, there was insufficient evidence to establish benefits or harms of VKAs or NOACs. Primary Funding Source: None. (PROSPERO: CRD42017079709

    JWST mirror and actuator performance at cryo-vacuum

    Get PDF
    The James Webb Space Telescope (JWST) telescope’s Secondary Mirror Assembly (SMA) and eighteen Primary Mirror Segment Assemblies (PMSAs) are each actively controlled in rigid body position via six hexapod actuators. Each of the PMSAs additionally has a radius of curvature actuator. The mirrors are stowed to the mirror support structure to survive the launch environment and then must be deployed 12.5 mm to reach the nominally deployed position before the Wavefront Sensing & Control (WFSC) alignment and phasing process begins. JWST requires testing of the full optical system in a Cryogenic Vacuum (CV) environment before launch. The cryo vacuum test campaign was executed in Chamber A at the Johnson Space Center (JSC) in Houston Texas. The test campaign consisted of an ambient vacuum test, a cooldown test, a cryo stable test at 65 Kelvin, a warmup test, and finally a second ambient vacuum test. Part of that test campaign was the functional and performance testing of the hexapod actuators on the flight mirrors. This paper will describe the testing that was performed on all 132 hexapod and radius of curvature actuators. The test campaign first tests actuators individually then tested how the actuators perform in the hexapod system. Telemetry from flight sensors on the actuators and measurements from external metrology devices such as interferometers, photogrammetry systems and image analysis was used to demonstrate the performance of the JWST actuators. The mirror move commanding process was exercised extensively during the JSC CV test and many examples of accurately commanded moves occurred. The PMSA and SMA actuators performed extremely well during the JSC CV test, and we have demonstrated that the actuators are fully functional both at ambient and cryo temperatures and that the mirrors will go to their commanded positions with the accuracy needed to phase and align the telescope

    Emotion and ethics: an inter-(en)active approach

    Get PDF
    The original publication is available at www.springerlink.comIn this paper we start exploring the affective and ethical dimension of what De Jaegher and Di Paolo (2007) have called ‘participatory sense-making’. In the first part, we distinguish various ways in which we are, and feel, affectively inter-connected in interpersonal encounters. In the second part, we discuss the ethical character of this affective interconnectedness, as well as the implications that taking an ‘inter-(en)active approach’ has for ethical theory itself
    • 

    corecore