1,297 research outputs found

    Accurate Numerical Modelling of MV and HV Resistive Dividers

    Get PDF
    An effective computational tool for the simulation and design of voltage dividers has been realized. It takes advantage from a finite element procedure for the accurate computation of the divider stray capacitances. These latter are then the input of a circuit solver procedure based on the modified node potential technique, which provides the divider frequency response. Furthermore, a test divider has been setup for the purpose of the tool validation. A very good agreement has been found between measured and computed results. This paper highlights that a correct representation of the resistors is necessary in the FEM model, during the computation of the stray parameters. This issue has been clarified for the first time in this paper. In addition, a comparison between FEM and BEM methods has been carried out before the implementation of the numerical code, stating the superior effectiveness of FEM. The computational tool has been finally tested on a real voltage divider. Good results have been found in terms of computational accuracy. Limited discrepancies between measured and computed results have been found up to 10 kHz, being 5.7 % for the scale factor and less than 24 mrad for the phase errors

    Comparison of different similarity measures in hierarchical clustering

    Get PDF
    The management of datasets containing heterogeneous types of data is a crucial point in the context of precision medicine, where genetic, environmental, and life-style information of each individual has to be analyzed simultaneously. Clustering represents a powerful method, used in data mining, for extracting new useful knowledge from unlabeled datasets. Clustering methods are essentially distance-based, since they measure the similarity (or the distance) between two elements or one element and the cluster centroid. However, the selection of the distance metric is not a trivial task: it could influence the clustering results and, thus, the extracted information. In this study we analyze the impact of four similarity measures (Manhattan or L1 distance, Euclidean or L2 distance, Chebyshev or L∞ distance and Gower distance) on the clustering results obtained for datasets containing different types of variables. We applied hierarchical clustering combined with an automatic cut point selection method to six datasets publicly available on the UCI Repository. Four different clusterizations were obtained for every dataset (one for each distance) and were analyzed in terms of number of clusters, number of elements in each cluster, and cluster centroids. Our results showed that changing the distance metric produces substantial modifications in the obtained clusters. This behavior is particularly evident for datasets containing heterogeneous variables. Thus, the choice of the distance measure should not be done a-priori but evaluated according to the set of data to be analyzed and the task to be accomplished

    A Wearable Multi-Sensor Array Enables the Recording of Heart Sounds in Homecare

    Get PDF
    The home monitoring of patients affected by chronic heart failure (CHF) is of key importance in preventing acute episodes. Nevertheless, no wearable technological solution exists to date. A possibility could be offered by Cardiac Time Intervals extracted from simultaneous recordings of electrocardiographic (ECG) and phonocardiographic (PCG) signals. Nevertheless, the recording of a good-quality PCG signal requires accurate positioning of the stethoscope over the chest, which is unfeasible for a naïve user as the patient. In this work, we propose a solution based on multi-source PCG. We designed a flexible multi-sensor array to enable the recording of heart sounds by inexperienced users. The multi-sensor array is based on a flexible Printed Circuit Board mounting 48 microphones with a high spatial resolution, three electrodes to record an ECG and a Magneto-Inertial Measurement Unit. We validated the usability over a sample population of 42 inexperienced volunteers and found that all subjects could record signals of good to excellent quality. Moreover, we found that the multi-sensor array is suitable for use on a wide population of at-risk patients regardless of their body characteristics. Based on the promising findings of this study, we believe that the described device could enable the home monitoring of CHF patients soon

    Key Aspects to Teach Medical Device Software Certification

    Get PDF
    Certification of Medical Device Software (MDS) according to the EU Medical Device Regulation 2017/745 requires demonstrating safety and effectiveness. Thus, the syllabus of a course on MDS development must provide tools for addressing these issues. To assure safety, risk analysis has to be performed using a four-step procedure. Effectiveness could be demonstrated by literature systematic review combined with meta-analysis, to compare the MDS performances with those of similar tools

    Automatic Identification of the Best Auscultation Area for the Estimation of the Time of Closure of Heart Valves through Multi-Source Phonocardiography

    Get PDF
    In the latest years, multi-source phonocardiography (PCG) is gaining interest in relation to the home monitoring of cardiovascular diseases. An application of interest regards the monitoring of the time of closure of the four cardiac valves, which would enable the follow-up of at-risk patients for heart failure. In this work, we propose a hybrid system based on hierarchical clustering and Multi-Criteria Decision Analysis (MCDA) for automatically selecting the best auscultation area for the mentioned application through multi-source PCG. We simultaneously recorded 48 PCG signals from the subject's chest and divided them into morphologically homogenous groups using agglomerative hierarchical clustering, based on their correlation. Then, we explored three different approaches to select the best auscultation area, based respectively on the minimum latency, on the maximum signal-to-noise ratio, and on multiple criteria using ELECTRE III. The results obtained on the follow-up of a healthy subject over consecutive days show that a) the selection of the auscultation area using MCDA overcomes the limits of single-criteria approaches, b) the estimate of the time of closure of the heart valves using the proposed system is more robust than what obtained through the state-of-the-art single-source methodology

    Design of a Service for the Management of Heart Failure Patients Using Telemedicine

    Get PDF
    The tremendous prevalence and mortality of heart failure (HF), along with the social and economic impact of its consequences, make an appropriate disease management utmost important. In this context, telemedicine offers promising possibilities. Current clinical guidelines and technological solutions do not address the problem of monitoring at-risk patients and patients affected by mild HF for prevention purposes. The goal of this work is to design a service based on a telemedicine framework for the management of heart failure patients. The proposed service grounds the monitoring of the patient on a custom multi-sensor array that we designed and developed for the purpose. The description of the processes involved in the service was carried out by means of Process Modelling tools, and in particular through Swim Lane Activity Diagrams. The results look promising for the implementation of the service in a real-life scenario. The main strength of the service resides in a) the use of noninvasive monitoring technologies to include patients with a mild HF or at-risk patients; and b) the integration of hospital and territory services to grant continuity and coherence in the treatment

    A simplified procedure for the Accurate Frequency Response Identification of Voltage Transformers

    Get PDF
    The paper proposes a simplified and affordable procedure for instrument transformers frequency characterization for medium voltage applications. It consists of a two steps measurement procedure, where both steps involve the generation of sine waves only, so that the it can be easily performed in instrument transformers calibration laboratories without requiring additional generation features. In the first step, a 50 Hz measurement of the Voltage Instrument Transformer ratio error at rated voltage is performed. The second step consists of a frequency sweep performed at low voltage up to the first resonance. By these two data sets, an approximated but accurate frequency response can be easily obtained using a non-linear fitted model. In the paper, a commercial voltage instrument transformer for medium voltage grids is characterized by the proposed method; results are shown and validated by comparison with a reference frequency characterization performed at INRIM under rated voltage
    • …
    corecore