1,070 research outputs found
Changes in tendon spatial frequency parameters with loading
To examine and compare the loading related changes in micro-morphology of the patellar tendon. Fifteen healthy young males (age 19±3yrs, body mass 83±5kg) were utilised in a within subjects matched pairs design. B mode ultrasound images were taken in the sagittal plane of the patellar tendon at rest with the knee at 90° flexion. Repeat images were taken whilst the subjects were carrying out maximal voluntary isometric contractions. Spatial frequency parameters related to the tendon morphology were determined within regions of interest (ROI) from the B mode images at rest and during isometric contractions. A number of spatial parameters were observed to be significantly different between resting and contracted images (Peak spatial frequency radius (PSFR), axis ratio, spatial Q-factor, PSFR amplitude ratio, and the sum). These spatial frequency parameters were indicative of acute alterations in the tendon micro-morphology with loading. Acute loading modifies the micro-morphology of the tendon, as observed via spatial frequency analysis. Further research is warranted to explore its utility with regard to different loading induced micro-morphological alterations, as these could give valuable insight not only to aid strengthening of this tissue but also optimization of recovery from injury and treatment of conditions such as tendinopathies
Goldstone Fermion Dark Matter
We propose that the fermionic superpartner of a weak-scale Goldstone boson
can be a natural WIMP candidate. The p-wave annihilation of this `Goldstone
fermion' into pairs of Goldstone bosons automatically generates the correct
relic abundance, whereas the XENON100 direct detection bounds are evaded due to
suppressed couplings to the Standard Model. Further, it is able to avoid
indirect detection constraints because the relevant s-wave annihilations are
small. The interactions of the Goldstone supermultiplet can induce non-standard
Higgs decays and novel collider phenomenology.Comment: 25 pages, 6 figures. References added, minor typos corrected.
Submitted to JHE
Photon echo studies of photosynthetic light harvesting
The broad linewidths in absorption spectra of photosynthetic complexes obscure information related to their structure and function. Photon echo techniques represent a powerful class of time-resolved electronic spectroscopy that allow researchers to probe the interactions normally hidden under broad linewidths with sufficient time resolution to follow the fastest energy transfer events in light harvesting. Here, we outline the technical approach and applications of two types of photon echo experiments: the photon echo peak shift and two-dimensional (2D) Fourier transform photon echo spectroscopy. We review several extensions of these techniques to photosynthetic complexes. Photon echo peak shift spectroscopy can be used to determine the strength of coupling between a pigment and its surrounding environment including neighboring pigments and to quantify timescales of energy transfer. Two-dimensional spectroscopy yields a frequency-resolved map of absorption and emission processes, allowing coupling interactions and energy transfer pathways to be viewed directly. Furthermore, 2D spectroscopy reveals structural information such as the relative orientations of coupled transitions. Both classes of experiments can be used to probe the quantum mechanical nature of photosynthetic light-harvesting: peak shift experiments allow quantification of correlated energetic fluctuations between pigments, while 2D techniques measure quantum beating directly, both of which indicate the extent of quantum coherence over multiple pigment sites in the protein complex. The mechanistic and structural information obtained by these techniques reveals valuable insights into the design principles of photosynthetic light-harvesting complexes, and a multitude of variations on the methods outlined here
Coherent excitation transferring via dark state in light-harvesting process
We study the light absorption and energy transferring in a donor-acceptor
system with a bionic structure. In the optimal case with uniform couplings, it
is found that the quantum dynamics of this seemingly complicated system is
reduced as a three-level system of -type. With this observation, we
show that the dark state based electromagnetically-induced transparency (EIT)
effect could enhance the energy transfer efficiency, through a quantum
interference effect suppressing the excited population of the donors. We
estimate the optimal parameters of the system to achieve the maximum output
power. The splitting behavior of maximum power may be used to explain the
phenomenon that the photosynthesis systems mainly absorb two colors of light.Comment: 4 pages, 3 figure
Pre-Stimulus Activity Predicts the Winner of Top-Down vs. Bottom-Up Attentional Selection
Our ability to process visual information is fundamentally limited. This leads to competition between sensory information that is relevant for top-down goals and sensory information that is perceptually salient, but task-irrelevant. The aim of the present study was to identify, from EEG recordings, pre-stimulus and pre-saccadic neural activity that could predict whether top-down or bottom-up processes would win the competition for attention on a trial-by-trial basis. We employed a visual search paradigm in which a lateralized low contrast target appeared alone, or with a low (i.e., non-salient) or high contrast (i.e., salient) distractor. Trials with a salient distractor were of primary interest due to the strong competition between top-down knowledge and bottom-up attentional capture. Our results demonstrated that 1) in the 1-sec pre-stimulus interval, frontal alpha (8–12 Hz) activity was higher on trials where the salient distractor captured attention and the first saccade (bottom-up win); and 2) there was a transient pre-saccadic increase in posterior-parietal alpha (7–8 Hz) activity on trials where the first saccade went to the target (top-down win). We propose that the high frontal alpha reflects a disengagement of attentional control whereas the transient posterior alpha time-locked to the saccade indicates sensory inhibition of the salient distractor and suppression of bottom-up oculomotor capture
Depth cues and perceived audiovisual synchrony of biological motion
Due to their different propagation times, visual and auditory signals from external events arrive at the human sensory receptors with a disparate delay. This delay consistently varies with distance, but, despite such variability, most events are perceived as synchronic. There is, however, contradictory data and claims regarding the existence of compensatory mechanisms for distance in simultaneity judgments.
Principal Findings:
In this paper we have used familiar audiovisual events – a visual walker and footstep sounds – and manipulated the number of depth cues. In a simultaneity judgment task we presented a large range of stimulus onset asynchronies corresponding to distances of up to 35 meters. We found an effect of distance over the simultaneity estimates, with greater distances requiring larger stimulus onset asynchronies, and vision always leading. This effect was stronger when both visual and auditory cues were present but was interestingly not found when depth cues were impoverished.
Significance:
These findings reveal that there should be an internal mechanism to compensate for audiovisual delays, which critically depends on the depth information available.FEDERFundação para a Ciência e a Tecnologia (FCT
Performance of Interleukin-6 and Interleukin-8 serum levels in pediatric oncology patients with neutropenia and fever for the assessment of low-risk
<p>Abstract</p> <p>Background</p> <p>Patients with chemotherapy-related neutropenia and fever are usually hospitalized and treated on empirical intravenous broad-spectrum antibiotic regimens. Early diagnosis of sepsis in children with febrile neutropenia remains difficult due to non-specific clinical and laboratory signs of infection. We aimed to analyze whether IL-6 and IL-8 could define a group of patients at low risk of septicemia.</p> <p>Methods</p> <p>A prospective study was performed to assess the potential value of IL-6, IL-8 and C-reactive protein serum levels to predict severe bacterial infection or bacteremia in febrile neutropenic children with cancer during chemotherapy. Statistical test used: Friedman test, Wilcoxon-Test, Kruskal-Wallis H test, Mann-Whitney U-Test and Receiver Operating Characteristics.</p> <p>Results</p> <p>The analysis of cytokine levels measured at the onset of fever indicated that IL-6 and IL-8 are useful to define a possible group of patients with low risk of sepsis. In predicting bacteremia or severe bacterial infection, IL-6 was the best predictor with the optimum IL-6 cut-off level of 42 pg/ml showing a high sensitivity (90%) and specificity (85%).</p> <p>Conclusion</p> <p>These findings may have clinical implications for risk-based antimicrobial treatment strategies.</p
- …