9,287 research outputs found
Passive-performance, analysis, and upgrades of a 1-ton seismic attenuation system
The 10m Prototype facility at the Albert-Einstein-Institute (AEI) in Hanover,
Germany, employs three large seismic attenuation systems to reduce mechanical
motion. The AEI Seismic-Attenuation-System (AEI-SAS) uses mechanical
anti-springs in order to achieve resonance frequencies below 0.5Hz. This system
provides passive isolation from ground motion by a factor of about 400 in the
horizontal direction at 4Hz and in the vertical direction at 9Hz. The presented
isolation performance is measured under vacuum conditions using a combination
of commercial and custom-made inertial sensors. Detailed analysis of this
performance led to the design and implementation of tuned dampers to mitigate
the effect of the unavoidable higher order modes of the system. These dampers
reduce RMS motion substantially in the frequency range between 10 and 100Hz in
6 degrees of freedom. The results presented here demonstrate that the AEI-SAS
provides substantial passive isolation at all the fundamental mirror-suspension
resonances
Huddle test measurement of a near Johnson noise limited geophone
In this paper, the sensor noise of two geophone configurations (L-22D and L-4C geophones from Sercel with custom built amplifiers) was measured by performing two huddle tests. It is shown that the accuracy of the results can be significantly improved by performing the huddle test in a seismically quiet environment and by using a large number of reference sensors to remove the seismic foreground signal from the data. Using these two techniques, the measured sensor noise of the two geophone configurations matched the calculated predictions remarkably well in the bandwidth of interest (0.01 Hz–100 Hz). Low noise operational amplifiers OPA188 were utilized to amplify the L-4C geophone to give a sensor that was characterized to be near Johnson noise limited in the bandwidth of interest with a noise value of 10−11 m/Hz⎯⎯⎯⎯⎯√10−11 m/Hz at 1 Hz
Measurement of Optical Response of a Detuned Resonant Sideband Extraction Interferometer
We report on the optical response of a suspended-mass detuned resonant
sideband extraction (RSE) interferometer with power recycling. The purpose of
the detuned RSE configuration is to manipulate and optimize the optical
response of the interferometer to differential displacements (induced by
gravitational waves) as a function of frequency, independently of other
parameters of the interferometer. The design of our interferometer results in
an optical gain with two peaks: an RSE optical resonance at around 4 kHz and a
radiation pressure induced optical spring at around 41 Hz. We have developed a
reliable procedure for acquiring lock and establishing the desired optical
configuration. In this configuration, we have measured the optical response to
differential displacement and found good agreement with predictions at both
resonances and all other relevant frequencies. These results build confidence
in both the theory and practical implementation of the more complex optical
configuration being planned for Advanced LIGO.Comment: 6 pages, 4 figures, for submission to Phys Rev Letter
Circadian rhythm of hepatic cytosolic and nuclear estrogen receptors
The distribution of estrogen receptor between the cytosolic and nuclear compartments were evaluated in liver of male rats to determine whether a circadian rhythm exists. Cytosolic receptor reached a maximum level at 400 hours and a minimum at 2000 and 2400 hr. Nuclear receptor reached a maximum level at 800 hr and was lowest at 1600 and 2000 hr. Serum estradiol levels were also highest at 800 hr and lowest at 1600 hr. The variations in cytosolic and nuclear receptors are not reciprocal; in fact, the overall content of receptor in the liver is not constant and also displays a circadian rhythm. © 1986 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted
Localization of a 64-kDa phosphoprotein in the lumen between the outer and inner envelopes of pea chloroplasts
The identification and localization of a marker protein for the intermembrane space between the outer and inner chloroplast envelopes is described. This 64-kDa protein is very rapidly labeled by [γ-32P]ATP at very low (30 nM) ATP concentrations and the phosphoryl group exhibits a high turnover rate. It was possible to establish the presence of the 64-kDa protein in this plastid compartment by using different chloroplast envelope separation and isolation techniques. In addition comparison of labeling kinetics by intact and hypotonically lysed pea chloroplasts support the localization of the 64-kDa protein in the intermembrane space. The 64-kDa protein was present and could be labeled in mixed envelope membranes isolated from hypotonically lysed plastids. Mixed envelope membranes incorporated high amounts of 32P from [γ-32P]ATP into the 64-kDa protein, whereas separated outer and inner envelope membranes did not show significant phosphorylation of this protein. Water/Triton X-114 phase partitioning demonstrated that the 64-kDa protein is a hydrophilic polypeptide. These findings suggest that the 64-kDa protein is a soluble protein trapped in the space between the inner and outer envelope membranes. After sonication of mixed envelope membranes, the 64-kDa protein was no longer present in the membrane fraction, but could be found in the supernatant after a 110000 × g centrifugation
Beam-target helicity asymmetry for γ→n→→π−p in the N*resonance region
We report the first beam-target double-polarization asymmetries in the γ þ nðpÞ → π− þ pðpÞ reaction
spanning the nucleon resonance region from invariant mass W ¼ 1500 to 2300 MeV. Circularly polarized
photons and longitudinally polarized deuterons in solid hydrogen deuteride (HD) have been used with the
CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. The exclusive final state has been
extracted using three very different analyses that show excellent agreement, and these have been used to
deduce the E polarization observable for an effective neutron target. These results have been incorporated
into new partial wave analyses and have led to significant revisions for several γnN* resonance
photocouplings
A QUANTITATIVE MAPPING OF ALKALINE PHOSPHATASE IN THE BRAIN OF THE RHESUS MONKEY *
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65477/1/j.1471-4159.1966.tb07513.x.pd
Microtubule-associated STOP protein deletion triggers restricted changes in dopaminergic neurotransmission.: Accumbic DA system in STOP KO mice
International audienceThe microtubule-associated stable tubule only polypeptide (STOP) protein plays a key-role in neuron architecture and synaptic plasticity. Recent studies suggest that schizophrenia is associated with alterations in the synaptic connectivity. Mice invalidated for the STOP gene display phenotype reminiscent of some schizophrenic-like symptoms, such as behavioral disturbances, dopamine (DA) hyper-reactivity, and possible hypoglutamatergia, partly improved by antipsychotic treatment. In the present work, we examined potential alterations in some DAergic key proteins and behaviors in STOP knockout mice. Whereas the densities of the DA transporter, the vesicular monoamine transporter and the D(1) receptor were not modified, the densities of the D(2) and D(3) receptors were decreased in some DAergic regions in mutant versus wild-type mice. Endogenous DA levels were selectively decreased in DAergic terminals areas, although the in vivo DA synthesis was diminished both in cell bodies and terminal areas. The DA uptake was decreased in accumbic synaptosomes, but not significantly altered in striatal synaptosomes. Finally, STOP knockout mice were hypersensitive to acute and subchronic locomotor effects of cocaine, although the drug equally inhibited DA uptake in mutant and wild-type mice. Altogether, these data showed that deletion of the ubiquitous STOP protein elicited restricted alterations in DAergic neurotransmission, preferentially in the meso-limbic pathway
A Cryogenic Silicon Interferometer for Gravitational-wave Detection
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor
- …