111 research outputs found

    Miniature photonic-crystal hydrophone optimized for ocean acoustics

    Full text link
    This work reports on an optical hydrophone that is insensitive to hydrostatic pressure, yet capable of measuring acoustic pressures as low as the background noise in the ocean in a frequency range of 1 Hz to 100 kHz. The miniature hydrophone consists of a Fabry-Perot interferometer made of a photonic-crystal reflector interrogated with a single-mode fiber, and is compatible with existing fiber-optic technologies. Three sensors with different acoustic power ranges placed within a sub-wavelength sized hydrophone head allow a high dynamic range in the excess of 160 dB with a low harmonic distortion of better than -30 dB. A method for suppressing cross coupling between sensors in the same hydrophone head is also proposed. A prototype was fabricated, assembled, and tested. The sensitivity was measured from 100 Hz to 100 kHz, demonstrating a minimum detectable pressure down to 12 {\mu}Pa (1-Hz noise bandwidth), a flatband wider than 10 kHz, and very low distortion

    Widely tunable thermo-optic plasmonic bandpass filter

    Get PDF
    We report thermally tunable optical bandpass filters based on long-range surface plasmon polariton waveguides. A thin gold stripe in the waveguide core is surrounded by dielectric layers with dissimilar refractive index dispersions and dissimilar thermo-optic coefficients. High filter transmission is achieved for a wavelength at which the refractive indices of the upper and lower cladding layers are identical, and this spectral point may be changed by varying the filter temperature. Experimentally, over 220 nm of bandpass tuning is achieved around 1550 nm wavelength by varying the device temperature from 19 to 27 degrees C. (C) 2013 AIP Publishing LLC.close3

    Harmonic cantilevers for nanomechanical sensing of elastic properties

    Get PDF
    We present a micromachined scanning probe cantilever, in which a specific higher order flexural mode is designed to be resonant at an exact integer multiple of the fundamental resonance frequency. We have demonstrated that such cantilevers enable sensing of nonlinear mechanical interactions between the atomically sharp tip at the free end of the cantilever and a surface with unknown mechanical properties in tapping-mode atomic force microscopy. © 2003 IEEE

    High-resolution imaging of elastic properties using harmonic cantilevers

    Get PDF
    We present a micromachined scanning probe cantilever, in which a specific higher-order flexural mode is designed to be resonant at an exact integer multiple of the fundamental resonance frequency. We have fabricated such cantilevers by reducing the stiffness of the third order flexural mode relative to the fundamental mode, and we have demonstrated that these cantilevers enable sensing of non-linear mechanical interactions between the atomically sharp tip at the free end of the cantilever and a surface with unknown mechanical properties in tapping-mode atomic force microscopy. Images of surfaces with large topographical variations show that for such samples harmonic imaging has better resolution than standard tapping-mode imaging. © 2003 Elsevier B.V. All rights reserved

    Do MRI findings identify patients with chronic low back pain and Modic changes who respond best to rest or exercise: A subgroup analysis of a randomised controlled trial

    Get PDF
    Background: No previous clinical trials have investigated MRI findings as effect modifiers for conservative treatment of low back pain. This hypothesis-setting study investigated if MRI findings modified response to rest compared with exercise in patients with chronic low back pain and Modic changes. Methods: This study is a secondary analysis of a randomised controlled trial comparing rest with exercise. Patients were recruited from a specialised outpatient spine clinic and included in a clinical trial if they had chronic low back pain and an MRI showing Modic changes. All patients received conservative treatment while participating in the trial. Five baseline MRI findings were investigated as effect modifiers: Modic changes Type 1 (any size), large Modic changes (any type), large Modic changes Type 1, severe disc degeneration and large disc herniation. The outcome measure was change in low back pain intensity measured on a 0-10 point numerical rating scale at 14-month follow-up (n = 96). An interaction = 1.0 point (0-10 scale) between treatment group and MRI findings in linear regression was considered clinically important. Results: The interactions for Modic Type 1, with large Modic changes or with large Modic changes Type 1 were all potentially important in size (-0.99 (95% CI -3.28 to 1.29), -1.49 (-3.73 to 0.75), -1.49 (-3.57 to 0.58), respectively) but the direction of the effect was the opposite to what we had hypothesized-that people with these findings would benefit more from rest than from exercise. The interactions for severe disc degeneration (0.74 (-1.40 to 2.88)) and large disc herniation (-0.92 (3.15 to 1.31)) were less than the 1.0-point threshold for clinical importance. As expected, because of the lack of statistical power, no interaction term for any of the MRI findings was statistically significant. Conclusions: Three of the five MRI predictors showed potentially important effect modification, although the direction of the effect was surprising and confidence intervals were wide so very cautious interpretation is required. Further studies with adequate power are warranted to study these and additional MRI findings as potential effect modifiers for common interventions

    The association between subgroups of MRI findings identified with latent class analysis and low back pain in 40-year old Danes

    Get PDF
    Background: Research into the clinical importance of spinal MRI findings in patients with low back pain (LBP) has primarily focused on single imaging findings, such as Modic changes or disc degeneration, and found only weak associations with the presence of pain. However, numerous MRI findings almost always co-exist in the lumbar spine and are often present at more than one lumbar level. It is possible that multiple MRI findings are more strongly associated with LBP than single MRI findings. Latent Class Analysis is a statistical method that has recently been tested and found useful for identifying latent classes (subgroups) of MRI findings within multivariable datasets. The purpose of this study was to investigate the association between subgroups of MRI findings and the presence of LBP in people from the general population. Methods: To identify subgroups of lumbar MRI findings with potential clinical relevance, Latent Class Analysis was initially performed on a clinical dataset of 631 patients seeking care for LBP. Subsequently, 412 participants in a general population cohort (the ‘Backs on Funen’ project) were statistically allocated to those existing subgroups by Latent Class Analysis, matching their MRI findings at a segmental level. The subgroups containing MRI findings from the general population were then organised into hypothetical pathways of degeneration and the association between subgroups in the pathways and the presence of LBP was tested using exact logistic regression. Results: Six subgroups were identified in the clinical dataset and the data from the general population cohort fitted the subgroups well, with a median posterior probability of 93%–100%. These six subgroups described two pathways of increasing degeneration on upper (L1-L3) and lower (L4-L5) lumbar levels. An association with LBP was found for the subgroups describing severe and multiple degenerative MRI findings at the lower lumbar levels but none of the other subgroups were associated with LBP

    Highly temporally resolved response to seasonal surface melt of the Zachariae and 79N outlet glaciers in northeast Greenland

    Get PDF
    The seasonal response to surface melting of the Northeast Greenland Ice Stream outlets, Zachariae and 79N, is investigated using new highly temporally resolved surface velocity maps for 2016 combined with numerical modeling. The seasonal speedup at 79N of 0.15 km/yr is suggested to be driven by a decrease in effective basal pressure induced by surface melting, whereas for Zachariae its 0.11 km/yr seasonal speedup correlates equally well with the breakup of its large ice mélange. We investigate the influence 76 km long floating tongue at 79N, finding it provides little resistance and that most of it could be lost without impacting the dynamics of the area. Furthermore, we show that reducing the slipperiness along the tongue-wall interfaces produces a velocity change spatially inconsistent with the observed seasonal speedup. Finally, we find that subglacial sticky spots such as bedrock bumps play a negligible role in the large-scale response to a seasonally enhanced basal slipperiness of the region

    Reliability of MRI findings in candidates for lumbar disc prosthesis

    Get PDF
    Introduction: Limited reliability data exist for localised magnetic resonance imaging (MRI) findings relevant to planning of treatment with lumbar disc prosthesis and later outcomes. We assessed the reliability of such findings in chronic low back pain patients who were accepted candidates for disc prosthesis. Methods: On pretreatment MRI of 170 patients (mean age 41 years; 88 women), three experienced radiologists independently rated Modic changes, disc findings and facet arthropathy at L3/L4, L4/L5 and L5/S1. Two radiologists rerated 126 examinations. For each MRI finding at each disc level, agreement was analysed using the kappa statistic and differences in prevalence across observers using a fixed effects model. Results: All findings at L3/L4 and facet arthropathy at L5/S1 had a mean prevalence <10% across observers and were not further analysed, ensuring interpretable kappa values. Overall interobserver agreement was generally moderate or good (kappa 0.40–0.77) at L4–S1 for Modic changes, nucleus pulposus signal, disc height (subjective and measured), posterior high-intensity zone (HIZ) and disc contour, and fair (kappa 0.24) at L4/L5 for facet arthropathy. Posterior HIZ at L5/S1 and severely reduced subjective disc height at L4/L5 differed up to threefold in prevalence between observers (p< 0.0001). Intraobserver agreement was mostly good or very good (kappa 0.60–1.00). Conclusion: In candidates for disc prosthesis, mostly moderate interobserver agreement is expected for localised MRI findings
    corecore