36 research outputs found

    Messung der isometrischen Dorsalextensions- und Plantarflexions- Kraft in den Sprunggelenken

    Get PDF
    Dieser Artikel beschreibt ein Messgerät zur Bestimmung der isometrischen Kraft in den Sprunggelenken in Dorsalextension und Plantarflexion. Durch die Kombination der Vorrichtung zur Bestimmung der freiwilligen isometrischen Maximalkraft in den Sprunggelenken, des Elektromyogrammes und der genauen Positionskontrolle des zumessenden Beines ist es z.B. möglich, einen objektiven Vergleich der Unterschiede der Muskulatur zwischen dem linken und rechten Bein, wie auch während der Rehabilitation nach einer Operation oder Verletzung zu bekommen. This article describes an easy to use test equipment for measuring the isometric force in the ankle joints in dorsiflexion and plantar flexion. The combination of the test equipment for measuring the voluntary maximal isometric muscle force in the ankle joint, the surface electromyograms and the motion analysis of the measured leg allow an objective comparison of the strength of the muscular force between the left and right leg. It might be also used as a control setup during rehabilitation after surgical treatment or injurie

    Use of isothermal microcalorimetry to monitor microbial activities

    Get PDF
    Isothermal calorimetry measures the heat flow of biological processes, which is proportional to the rate at which a given chemical or physical process takes place. Modern isothermal microcalorimeters make measurements of less than a microwatt of heat flow possible. As a result, as few as 10 000-100 000 active bacterial cells in culture are sufficient to produce a real-time signal dynamically related to the number of cells present and their activity. Specimens containing bacteria need little preparation, and isothermal microcalorimetry (IMC) is a nondestructive method. After IMC measurements, the undisturbed samples can be evaluated by any other means desired. In this review, we present a basic description of microcalorimetry and examples of microbiological applications of IMC for medical and environmental microbiology. In both fields, IMC has been used to quantify microbial activity over periods of hours or even days. Finally, the recent development of highly parallel instruments (up to 48 channels) and the constantly decreasing costs of equipment have made IMC increasingly attractive for microbiology. Miniaturization of isothermal calorimeters provides an even wider range of possibilitie

    Forearm pressure distribution during ambulation with elbow crutches: a cross-sectional study

    Get PDF
    Increasing numbers of patients require permanent walking aids to maintain mobility. Current elbow crutches are not designed for long-term use, and overuse is often associated with hematoma formation and pain along the forearm. We therefore hypothesized that the highest pressures between the forearm and crutch cuff during walking and stance are located in the ulnar region and that the level of weight-bearing, forearm circumference and kinematic parameters influence peak pressure values and pressure distribution.; Ten healthy adults participated in a cross-sectional study. A pressure sensor array was attached to the forearm of each participant separating the forearm into four quadrants (lateral, ulnar, intermediate and medial). Measurements were taken during crutch gait and during partial and full weight-bearing stance. A three-dimensional motion analysis system with reflective markers attached to the subject's body and to the crutches was used to obtain kinematic data.; The mean pressure on the forearm during crutch gait was 37.5 kPa (SD 8.8 kPa). Highest mean pressure values were measured in the ulnar (41.0 kPa, SD 9.6 kPa) and intermediate (38.0 kPa, SD 9.0 kPa) quadrants. The center of pressure was mainly located in an oblique lamellar area in these two quadrants. With increasing weight-bearing on the crutches during stance, we observed a shift of the peak pressures towards the ulnar quadrant. The circumference of the forearm correlated with the peak pressure in the medial and intermediate quadrants during crutch gait (P < 0.05). Peak pressures on the forearm showed a trend towards correlation with crutch abduction, but no association with other kinematic parameters was detected.; The pressure load on the forearm during crutch-assisted gait is located predominantly over the ulna and may be linked to a range of secondary conditions caused by crutch use including hematoma formation and pain

    Probing Corticospinal Control During Different Locomotor Tasks Using Detailed Time-Frequency Analysis of Electromyograms

    Get PDF
    Locomotion relies on the fine-tuned coordination of different muscles which are controlled by particular neural circuits. Depending on the attendant conditions, walking patterns must be modified to optimally meet the demands of the task. Assessing neuromuscular control during dynamic conditions is methodologically highly challenging and prone to artifacts. Here we aim at assessing corticospinal involvement during different locomotor tasks using non-invasive surface electromyography. Activity in tibialis anterior (TA) and gastrocnemius medialis (GM) muscles was monitored by electromyograms (EMGs) in 27 healthy volunteers (11 female) during regular walking, walking while engaged in simultaneous cognitive dual tasks, walking with partial visual restriction, and skilled, targeted locomotion. Whereas EMG intensity of the TA and GM was considerably altered while walking with partial visual restriction and during targeted locomotion, dual-task walking induced only minor changes in total EMG intensity compared to regular walking. Targeted walking resulted in enhanced EMG intensity of GM in the frequency range associated with Piper rhythm synchronies. Likewise, targeted walking induced enhanced EMG intensity of TA at the Piper rhythm frequency around heelstrike, but not during the swing phase. Our findings indicate task- and phase-dependent modulations of neuromuscular control in distal leg muscles during various locomotor conditions in healthy subjects. Enhanced EMG intensity in the Piper rhythm frequency during targeted walking points toward enforced corticospinal drive during challenging locomotor tasks. These findings indicate that comprehensive time-frequency EMG analysis is able to gauge cortical involvement during different movement programs in a non-invasive manner and might be used as complementary diagnostic tool to assess baseline integrity of the corticospinal tract and to monitor changes in corticospinal drive as induced by neurorehabilitation interventions or during disease progression

    Messung der isometrischen Dorsalextensions- und Plantarflexions- Kraft in den Sprunggelenken = Measurement of the isometric dorsiflexion and plantar flexion force in the ankle joint

    No full text
    This article describes an easy to use test equipment for measuring the isometric force in the ankle joints in dorsiflexion and plantar flexion. The combination of the test equipment for measuring the voluntary maximal isometric muscle force in the ankle joint, the surface electromyograms and the motion analysis of the measured leg allow an objective comparison of the strength of the muscular force between the left and right leg. It might be also used as a control setup during rehabilitation after surgical treatment or injuries

    Biomedical Use of Isothermal Microcalorimeters

    Get PDF
    Isothermal microcalorimetry is becoming widely used for monitoring biological activities in vitro. Microcalorimeters are now able to measure heat production rates of less than a microwatt. As a result, metabolism and growth of relatively small numbers of cultured bacteria, protozoans, human cells and even small animals can be monitored continuously and extremely accurately at any chosen temperature. Dynamic effects on these organisms of changes in the culture environment—or of additions to it—are easily assessed over periods from hours to days. In addition microcalorimetry is a non-destructive method that does not require much sample preparation. It is also completely passive and thus allows subsequent evaluations of any kind on the undisturbed sample. In this review, we present a basic description of current microcalorimetry instruments and an overview of their use for various biomedical applications. These include detecting infections, evaluating effects of pharmaceutical or antimicrobial agents on cells, monitoring growth of cells harvested for tissue eingineering, and assessing medical and surgical device material physico-chemical stability and cellular biocompatibility

    Effect of the upper limbs muscles activity on the mechanical energy gain in pole vaulting

    No full text
    The shoulder muscles are highly solicited in pole vaulting and may afford energy gain. The objective of this study was to determine the bilateral muscle activity of the upper-limbs to explain the actions performed by the vaulter to bend the pole and store elastic energy. Seven experienced athletes performed 5-10 vaults which were recorded using two video cameras (50Hz). The mechanical energy of the centre of gravity (CG) was computed, while surface electromyographic (EMG) profiles were recorded from 5 muscles bilateral: deltoideus, infraspinatus, biceps brachii, triceps, and latissimus dorsi muscles. The level of intensity from EMG profile was retained in four sub phases between take-off (TO1) and complete pole straightening (PS). The athletes had a mean mechanical energy gain of 22% throughout the pole vault, while the intensities of deltoideus, biceps brachii, and latissimus dorsi muscles were sub phases-dependent (p>0.05). Stabilizing the glenohumeral joint (increase of deltoideus and biceps brachii activity) and applying a pole bending torque (increase of latissimus dorsi activity) required specific muscle activation. The gain in mechanical energy of the vaulter could be linked to an increase in muscle activation, especially from latissimusdorsi muscles

    Influence of Kinematics and Muscular Activations on Pole Vault Performance

    No full text
    From the 17th Congress of the European Society of Biomechanics, Edinburgh (UK), 5-8th July 2010.International audienceforthcomin
    corecore