30 research outputs found

    Clinical applications of 7T MRI in the brain

    Get PDF
    AbstractThis review illustrates current applications and possible future directions of 7Tesla (7T) Magnetic Resonance Imaging (MRI) in the field of brain MRI, in clinical studies as well as clinical practice. With its higher signal-to-noise (SNR) and contrast-to-noise ratio (CNR) compared to lower field strengths, high resolution, contrast-rich images can be obtained of diverse pathologies, like multiple sclerosis (MS), brain tumours, aging-related changes and cerebrovascular diseases. In some of these diseases, additional pathophysiological information can be gained compared to lower field strengths. Because of clear depiction of small anatomical details, and higher lesion conspicuousness, earlier diagnosis and start of treatment of brain diseases may become possible. Furthermore, additional insight into the pathogenesis of brain diseases obtained with 7T MRI could be the basis for new treatment developments. However, imaging at high field comes with several limitations, like inhomogeneous transmit fields, a higher specific absorption rate (SAR) and, currently, extensive contraindications for patient scanning. Future studies will be aimed at assessing the advantages and disadvantages of 7T MRI over lower field strengths in light of clinical applications, specifically the additional diagnostic and prognostic value of 7T MRI

    7 T renal MRI: challenges and promises

    Get PDF
    The progression to 7 Tesla (7 T) magnetic resonance imaging (MRI) yields promises of substantial increase in signal-to-noise (SNR) ratio. This increase can be traded off to increase image spatial resolution or to decrease acquisition time. However, renal 7 T MRI remains challenging due to inhomogeneity of the radiofrequency field and due to specific absorption rate (SAR) constraints. A number of studies has been published in the field of renal 7 T imaging. While the focus initially was on anatomic imaging and renal MR angiography, later studies have explored renal functional imaging. Although anatomic imaging remains somewhat limited by inhomogeneous excitation and SAR constraints, functional imaging results are promising. The increased SNR at 7 T has been particularly advantageous for blood oxygen level-dependent and arterial spin labelling MRI, as well as sodium MR imaging, thanks to changes in field-strength-dependent magnetic properties. Here, we provide an overview of the currently available literature on renal 7 T MRI. In addition, we provide a brief overview of challenges and opportunities in renal 7 T MR imaging

    Improving advanced intraoperative MRI methods during pediatric neurosurgery

    Get PDF
    Advanced intraoperative MR images (ioMRI) acquired during the resection of pediatric brain tumors could offer additional physiological information to preserve healthy tissue. With this work, we aimed to develop a protocol for ioMRI with increased sensitivity for arterial spin labeling (ASL) and diffusion MRI (dMRI), optimized for patient positioning regularly used in the pediatric neurosurgery setting. For ethical reasons, ASL images were acquired in healthy adult subjects that were imaged in the prone and supine position. After this, the ASL cerebral blood flow (CBF) was quantified and compared between both positions. To evaluate the impact of the RF coils setups on image quality, we compared different setups (two vs. four RF coils) by looking at T1-weighted (T1w) signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), as well as undertaking a qualitative evaluation of T1w, T2w, ASL, and dMR images. Mean ASL CBF did not differ between the surgical prone and supine positions in any of the investigated regions of interest or the whole brain. T1w SNR (gray matter: p = 0.016, 34% increase; white matter: p = 0.016, 32% increase) and CNR were higher (p = 0.016) in the four versus two RF coils setups (18.0 ± 1.8 vs. 13.9 ± 1.8). Qualitative evaluation of T1w, T2w, ASL, and dMR images resulted in acceptable to good image quality and did not differ statistically significantly between setups. Only the nonweighted diffusion image maps and corticospinal tract reconstructions yielded higher image quality and reduced susceptibility artifacts with four RF coils. Advanced ioMRI metrics were more precise with four RF coils as the standard deviation decreased. Taken together, we have investigated the practical use of advanced ioMRI during pediatric neurosurgery. We conclude that ASL CBF quantification in the surgical prone position is valid and that ASL and dMRI acquisition with two RF coils can be performed adequately for clinical use. With four versus two RF coils, the SNR of the images increases, and the sensitivity to artifacts reduces

    The YOUth cohort study: MRI protocol and test-retest reliability in adults

    Get PDF
    The YOUth cohort study is a unique longitudinal study on brain development in the general population. As part of the YOUth study, 2000 children will be included at 8, 9 or 10 years of age and planned to return every three years during adolescence. Magnetic resonance imaging (MRI) brain scans are collected, including structural T1-weighted imaging, diffusion-weighted imaging (DWI), resting-state functional MRI and task-based functional MRI. Here, we provide a comprehensive report of the MR acquisition in YOUth Child & Adolescent including the test-retest reliability of brain measures derived from each type of scan. To measure test-retest reliability, 17 adults were scanned twice with a week between sessions using the full YOUth MRI protocol. Intraclass correlation coefficients were calculated to quantify reliability. Global brain measures derived from structural T1-weighted and DWI scans were reliable. Resting-state functional connectivity was moderately reliable, as well as functional brain measures for both the inhibition task (stop versus go) and the emotion task (face versus house). Our results complement previous studies by presenting reliability results of regional brain measures collected with different MRI modalities. YOUth facilitates data sharing and aims for reliable and high-quality data. Here we show that using the state-of-the art YOUth MRI protocol brain measures can be estimated reliably

    FLAIR images at 7 Tesla MRI highlight the ependyma and the outer layers of the cerebral cortex.

    No full text
    Objectives: Fluid-attenuated inversion recovery (FLAIR) imaging is an important clinical ‘work horse’ for brain MRI and has proven to facilitate imaging of both intracortical lesions as well as cortical layers at 7 T MRI. A prominent observation on 7 T FLAIR images is a hyperintense rim at the cortical surface and around the ventricles.We aimed to clarify the anatomical correlates and underlying contrast mechanisms of this hyperintense rim. Materials and Methods: Two experiments with post-mortem human brain tissue were performed. FLAIR and T2-weighted imageswere obtained at typical in vivo (0.8mmisotropic) and high resolution (0.25mmisotropic). At one location the cortical surfacewas partly removed, and scanned again. Imagingwas followed by histological and immunohistochemical analysis. Additionally, several simulations were performed to evaluate the potential contribution from an artifact due to water diffusion. Results: The hyperintense rim corresponded to the outer – glia rich – layer of the cortex and disappeared upon removal of that layer. At the ventricles, the rim corresponded to the ependymal layer, and was not present at white matter/fluid borders at an artificial cut. The simulations supported the hypothesis that the hyperintense rim reflects the tissue properties in the outer cortical layers (or ependymal layer for the ventricles), and is not merely an artifact, although not all observations were explained by the simulated model of the contrast mechanism. Conclusions: 7 T FLAIR seems to amplify the signal from layers I–III of the cortex and the ependyma around the ventricles. Although diffusion of water from layer I into CSF does contribute to this effect, a long T2 relaxation time constant in layer I, and probably also layer II–III, is most likely themajor contributor, since the rimdisappears upon removal of that layer. This knowledge can help the interpretation of imaging results in cortical development and in patients with cortical pathology

    3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study

    Get PDF
    Background: Pre-clinical detection of atherosclerosis enables personalized preventive strategies in asymptomatic individuals. Cardiovascular magnetic resonance (CMR) has evolved as an attractive imaging modality for studying atherosclerosis in vivo. Yet, the majority of aortic CMR studies and proposed sequences to date have been performed at 1.5 tesla using 2D BB techniques and a slice thickness of 4-5 mm. Here, we evaluate for the first time the reproducibility of an isotropic, T1-weighted, three-dimensional, black-blood, CMR VISTA sequence (3D-T1-BB-VISTA) for quantification of aortic wall characteristics in healthy, young adults. Methods: In 20 healthy, young adults (10 males, mean age 31.3 years) of the AMBITYON cohort study the descending thoracic aorta was imaged with a 3.0 T MR system using the 3D-T1-BB-VISTA sequence. The inter-scan, inter-rater and intra-rater reproducibility of aortic lumen, total vessel and wall area and mean and maximum wall thickness was evaluated using Bland-Altman analyses and Intraclass Correlation Coefficients (ICC). Based on these findings, sample sizes for detecting differences in aortic wall characteristics between groups were calculated. Results: For each studied parameter, the inter-scan, inter-rater and intra-rater reproducibility was excellent as indicated by narrow limits of agreement and high ICCs (ranging from 0.76 to 0.99). Sample sizes required to detect a 5 % difference in aortic wall characteristics between two groups were 203, 126, 136, 68 and 153 per group for lumen area, total vessel area and vessel wall area and for mean and maximum vessel wall thickness, respectively. Conclusion: The 3D-T1-BB-VISTA sequence provides excellent reproducibility for quantification of aortic wall characteristics and can detect small differences between groups with reasonable sample sizes. Hence, it may be a valuable tool for assessment of the subtle vascular wall changes of early atherosclerosis in asymptomatic populations

    No evidence of microbleeds in ALS patients at 7 Tesla MRI

    No full text
    There have been several reports about disruption of the blood-spinal cord barrier (BSCB) and blood-brain barrier (BBB) in SOD1 mutant mice. Pathologically, microbleeds and hemosiderine deposits were found. We investigated patients with ALS for the occurrence of cerebral microbleeds with 7 Tesla MRI. Twelve patients with ALS and 12 age- and sex-matched healthy controls were studied. We performed T2*-weighed imaging which enables whole-brain in vivo detection of cerebral microbleeds and hemosiderin deposits in humans. No microbleeds were found in patients with ALS
    corecore