53 research outputs found

    Lower corneal hysteresis in glaucoma patients with acquired pit of the optic nerve (APON)

    Get PDF
    Objective: Acquired pit-like changes of the optic nerve head (APON) are characteristic of glaucomatous damage and may be a sign of a localized susceptibility of the optic nerve. Thus, it is possible that biomechanical properties of the ocular tissues may play a pressure-independent role in the pathogenesis of glaucoma. Corneal hysteresis (CH) appears to provide information of the biomechanical properties of the ocular hull tissues. The purpose of this study was to compare CH of patients with primary open angle glaucoma (POAG) with and without APON. Methods: A prospective case control study was done. POAG patients with and without APON were measured using the Ocular Response Analyzer by masked investigators. Patients in both groups were matched for sex, age, corneal thickness, and type of glaucoma according to maximal IOP (NTG or POAG). Statistical analysis was done using ANOVA. Results: Corneal hysteresis of 16 glaucomatous eyes with APON and 32 controls (glaucoma without APON) was measured. The mean (±SD) CH in the APON group was 8.89 (±1.53) and 10.2 (±1.05) in the control group. The difference is statistically significant (p = 0.005). Conclusions: Corneal hysteresis in POAG patients with APON was significantly lower than in patients that did not have such structural changes of the optic disc. These findings may reflect pressure-independent mechanisms involved in the pathogenesis of such glaucomatous optic nerve change

    Reproducibility of straylight measurement by C-Quant for assessment of retinal straylight using the compensation comparison method

    Get PDF
    Background: Straylight gives the appearance of a veil of light thrown over a person's retinal image when there is a strong light source present. We examined the reproducibility of the measurements by C-Quant, and assessed its correlation to characteristics of the eye and subjects' age. Participants and Methods: Five repeated straylight measurements were taken using the dominant eye of 45 healthy subjects (age 21-59) with a BCVA of 20/20: 14 emmetropic, 16 myopic, eight hyperopic and seven with astigmatism. We assessed the extent of reproducibility of straylight measures using the intraclass correlation coefficient. Results: The mean straylight value of all measurements was 1.01 (SD 0.23, median 0.97, interquartile range 0.85-1.1). Per 10years of age, straylight increased in average by 0.10 (95%CI 0.04 to 0.16, p < 0.01]. We found no independent association of refraction (range −5.25 dpt to +2 dpt) on straylight values (0.001; 95%CI −0.022 to 0.024, p = 0.92). Compared to emmetropic subjects, myopia reduced straylight (−.011; −0.024 to 0.02, p = 0.11), whereas higher straylight values (0.09; −0.01 to 0.20, p = 0.09) were observed in subjects with blue irises as compared to dark-colored irises when correcting for age. The intraclass correlation coefficient (ICC) of repeated measurements was 0.83 (95%CI 0.76 to 0.90). Conclusions: Our study showed that straylight measurements with the C-Quant had a high reproducibility, i.e. a lack of large intra-observer variability, making it appropriate to be applied in long-term follow-up studies assessing the long-term effect of surgical procedures on the quality of visio

    On the Suitability of Estelle for Multimedia Systems

    Full text link
    Formal Description Techniques have been widely used for the specification of traditional networked applications. They have not been applied to the specification of new applications such as multimedia systems yet. In this paper, we examine the FDT Estelle with respect to its suitability for multimedia system specification and automatic derivation of efficient implementations. We show that it is possible to specify certain aspects of multimedia systems, but that Estelle is not sufficient for others. The derived implementations often perform badly. We show the reasons and propose to use a slightly modified Estelle syntax and semantics to solve the problems. The implemented solution was tested successfully

    ISRCTN12125882 - Influence of topical anti-VEGF (Ranibizumab) on the outcome of filtration surgery for glaucoma - Study Protocol

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Excessive wound healing, with scarring of the episcleral tissue or encapsulation of the filtering bleb is the main reason for failure in trabeculectomy. Ranibizumab, an inhibitor of the Vascular Endothelial Growth Factor (VEGF), is seen as a promising candidate to prevent or treat extensive wound healing. We describe the design of a two phased study, i) assessing the local tolerability and safety of topical ranibizumab and ii) assessing the efficacy of topical ranibizumab against placebo in patients who underwent trabeculectomy with mitomycin C combined with phacoemulsification and intra ocular lens (IOL) implantation.</p> <p>Methods/Design</p> <p>In the first phase five patients that had trabeculectomy with mitomycin C combined with phacoemulsification and IOL implantation will be treated with topical ranibizumab (Lucentis<sup>®</sup>) eye drops (2 mg/ml) four times daily for one month. The treatment will be started at the first postoperative day. Patients will be assessed for local and systemic side effects using a standardised schedule. In the second phase, after successful completion of phase 1, consenting eligible patients who underwent trabeculectomy with mitomycin C combined with phacoemulsification and IOL implantation will be randomised to either receive topical ranibizumab eye drops (2 mg/ml) four times daily for 1 month or placebo (BSS 4x/d for 1 month). Patients will be reviewed weekly for 4 weeks until conjunctival sutures are removed. Further follow up examinations are planned after 3 and six months. Assessment of differences in the intraocular eye pressure will be considered primary, and bleb appearance/vascularisation using a standardized photography and the Moorfields bleb grading system, postoperative intraocular pressure and conjunctival wound healing problems will be considered secondary outcome parameters.</p> <p>Discussion</p> <p>Anti-VEGF-antibodies might be more effective in preventing scaring and might have fewer toxic side effects than the currently used anti-metabolites and may replace them in the long term.</p> <p>Trial Registration</p> <p>ISRCTN: <a href="http://www.controlled-trials.com/ISRCTN12125882">ISRCTN12125882</a></p

    Epidemiological Evidence for Work Load as a Risk Factor for Osteoarthritis of the Hip: A Systematic Review

    Get PDF
    Osteoarthritis of the hip (OA) is a common degenerative disorder of the joint cartilage that presents a major public health problem worldwide. While intrinsic risk factors (e.g, body mass and morphology) have been identified, external risk factors are not well understood. In this systematic review, the evidence for workload as a risk factor for hip OA is summarized and used to derive recommendations for prevention and further research.Epidemiological studies on workload or occupation and osteoarthritis of the hip were identified through database and bibliography searches. Using pre-defined quality criteria, 30 studies were selected for critical evaluation; six of these provided quantitative exposure data.Study results were too heterogeneous to develop pooled risk estimates by specific work activities. The weight of evidence favors a graded association between long-term exposure to heavy lifting and risk of hip OA. Long-term exposure to standing at work might also increase the risk of hip OA.It is not possible to estimate a quantitative dose-response relationship between workload and hip OA using existing data, but there is enough evidence available to identify job-related heavy lifting and standing as hazards, and thus to begin developing recommendations for preventing hip OA by limiting the amount and duration of these activities. Future research to identify specific risk factors for work-related hip OA should focus on implementing rigorous study methods with quantitative exposure measures and objective diagnostic criteria

    Nano-Opto-Electro-Mechanical Systems

    Get PDF
    A new class of hybrid systems that couple optical, electrical and mechanical degrees of freedom in nanoscale devices is under development in laboratories worldwide. These nano-opto-electro-mechanical systems (NOEMS) offer unprecedented opportunities to dynamically control the flow of light in nanophotonic structures, at high speed and low power consumption. Drawing on conceptual and technological advances from cavity optomechanics, they also bear the potential for highly efficient, low-noise transducers between microwave and optical signals, both in the classical and quantum domains. This Progress Article discusses the fundamental physical limits of NOEMS, reviews the recent progress in their implementation, and suggests potential avenues for further developments in this field.Comment: 27 pages, 3 figures, 2 boxe
    corecore